CoChat

Model-Based Health Diagnosis for Lithium-Ion Battery Pack in Space Applications

Song, Yuchen, Peng, Yu, Liu, Datong · 2021 · IEEE Transactions on Industrial Electronics
Cited by 75

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Lithium-ion battery packs are critical to ensure the operational reliability and service life of spacecraft. The battery pack health diagnosis is meaningful for reasonable mission plan and proper control actions of spacecraft. However, the characters of space application scenarios include periodic charge and discharge, nearly constant discharge current, low electric current rate, and fixed depth of discharge, which bring challenges to battery pack state-of-health estimation. Considering these characters, this article proposes a health diagnosis approach for lithium-ion battery pack based on an improved equivalent circuit model. First, an empirical model is introduced into the standard first-order equivalent circuit model to improve the accuracy of discharge process modeling under constant current. Furthermore, a parameter lookup table is developed to simulate the complete discharge based on the in-orbit partial discharge. Finally, the battery pack complete discharge process is virtually conducted to realize battery pack capacity estimation. The proposed method just satisfies the special operating conditions in space applications. The proposed method is validated based on a real tested lithium-ion battery pack. And the results indicate that the proposed method can realize the high-accurate health diagnosis for both battery pack and its inner cells under space operating conditions, which illustrate the adaptability and applicability of the proposed method in space applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2020.3045745

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 35

  1. 10.1016/S0076-6879(04)84011-4 · DOI · Paper page
  2. 10.1016/j.jpowsour.2006.01.052 · DOI
  3. 10.1109/TIE.2018.2880668 · DOI · Paper page
  4. 10.1016/j.est.2020.101250 · DOI · Paper page
  5. 10.1016/j.energy.2020.116944 · DOI
  6. 10.1109/ESPC47532.2019.9049261 · doi:10.1109/espc47532.2019.9049261
  7. 10.1109/MAES.2011.5936184 · DOI
  8. 10.1016/j.cja.2017.11.010 · DOI · Paper page
  9. 10.2172/1186745 · doi:10.2172/1186745
  10. 10.1016/j.apenergy.2019.04.108 · DOI · Paper page
  11. 10.1109/TIE.2015.2461523 · DOI · Paper page
  12. 10.1109/TII.2012.2222650 · DOI · Paper page
  13. porto, 2020, A discussion on algorithms for health monitoring, fault prognosis and RUL prediction of aerospace and automotive equipment, SAE Tech Paper 2019-36-0264
  14. 10.1016/j.jclepro.2018.06.182 · DOI · Paper page
  15. 10.1016/j.apenergy.2016.01.125 · DOI · Paper page
  16. 10.1109/TIE.2018.2880703 · DOI · Paper page
  17. 10.1016/j.apenergy.2017.05.176 · DOI · Paper page
  18. 10.1016/j.microrel.2017.06.045 · DOI · Paper page
  19. 10.1109/ACCESS.2020.2992206 · DOI
  20. 10.1109/TIE.2020.3001836 · DOI
  21. 10.1016/j.egypro.2017.03.816 · doi:10.1016/j.egypro.2017.03.816
  22. 10.1109/I2MTC.2019.8827097 · DOI
  23. 10.1016/j.rser.2019.05.042 · DOI · Paper page
  24. 10.1016/j.electacta.2018.02.020 · DOI · Paper page
  25. 10.1016/j.jpowsour.2013.11.101 · DOI · Paper page
  26. 10.1109/TIE.2018.2889623 · DOI
  27. 10.1109/TIE.2017.2701790 · DOI
  28. 10.1016/j.apenergy.2016.08.138 · DOI · Paper page
  29. abdi, 0, The Kendall rank correlation coefficient, Encyclopedia of Measurement and Statistics N, 508
  30. 10.3390/en12244772 · DOI
  31. 10.1007/978-3-642-00296-0_5 · DOI · Paper page
  32. 10.1109/TPEL.2018.2877294 · DOI · Paper page
  33. 10.1115/1.4042987 · DOI · Paper page
  34. 10.1080/01621459.1972.10481251 · DOI · Paper page
  35. 10.1016/j.est.2018.11.020 · DOI · Paper page

Cited by

Metadata

Authors
Song, Y., Peng, Y., & Liu, D.
Venue
IEEE Transactions on Industrial Electronics
Published
2021-12
Volume
68
Issue
12
Pages
12375-12384
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W3117079068
Cited by
75
References
8
FWCI
2.75
Type
journal article
Language
en
Open access
closed
Funders
National Natural Science Foundation of China (61771157)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Model-Based Health Diagnosis for Lithium-Ion Battery Pack in Space Applications. https://app.cochat.ai/papers/10.1109/tie.2020.3045745
The paper
Song, Y., Peng, Y., & Liu, D. (2021). Model-Based Health Diagnosis for Lithium-Ion Battery Pack in Space Applications. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2020.3045745

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.