Cited by 107Microgrid Control and OptimizationIslanding Detection in Power SystemsWind Turbine Control Systems

A Power-Angle-Based Adaptive Overcurrent Protection Scheme for Grid-Forming Inverter Under Large Grid Disturbances

Open access
Huang, Liang, Wu, Chao, Zhou, Dao, Blaabjerg, Frede·2023·IEEE Transactions on Industrial Electronics

Abstract

As the capacity of renewable energy generation increases, grid-forming (GFM) inverters are deemed as promising solutions for low inertia power grids. However, power-electronic-based inverters have limited overcurrent capability, so additional overcurrent protection schemes are necessary. More importantly, the stability should not be jeopardized by using additional overcurrent protection schemes. However, GFM inverters with the conventional current reference limiting method tend to be unstable under large grid disturbances such as grid frequency drop. To address this problem, this article proposes a virtual power angle limiting method. The main idea of this method is to limit the output power by limiting the power angle instead of directly limiting the current reference. Thus, the power synchronization control law is still satisfied when the overcurrent protection is triggered, so that the stability can be maintained. Besides, after redesigning the power angle limiting value, the proposed method is also suitable for grid voltage sag cases. A significant advantage of the proposed method is that the output current can be limited automatically during grid voltage sag or frequency drop events without the need of fault detection or tuning control structures and parameters. Simulation and experimental results have verified the effectiveness of the proposed method.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2022.3199906

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Inverters have low thermal inertia, which imposes restrictions on their overload capability in all operating modes, usually up to 1.3-1.5 of rated current.

    “Inverters have low thermal inertia, which imposes restrictions on their overload capability in all operating modes, usually up to 1.3-1.5 of rated current [34,35].”

    From Determining Volt/Var Characteristics of Electric Vehicle Charging Station Inverters for Voltage Regulation in Distribution Networks (2024) · cites this paper as [35]

    The available passages contain bibliographic information and overcurrent-protection keywords, but no substantive discussion of overload capability. Searches for thermal inertia, current limits, and 1.3–1.5 times rated current found no passage addressing the claim. (LLM, conf=0.72)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cited by

Sorted by citations

Authors
Huang, L., Wu, C., Zhou, D., & Blaabjerg, F.
Affiliations
  • Aalborg University (DK)
  • Shanghai Jiao Tong University (CN)
Venue
IEEE Transactions on Industrial Electronics
Published
2023-06
Volume
70
Issue
6
Pages
5927-5936
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W4292969013
Cited by
107
References
0
Citations by year
2026: 25 · 2025: 40 · 2024: 25 · 2023: 17
FWCI
8.26
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Industrial Electronics (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (publishedVersion, other-oa)
Funders
Velux Fonden (REPEPS 00016591)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
Keywords
overcurrent protection, grid-forming inverters, grid voltage sag, low-inertia power systems, power synchronization control, renewable energy integration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review