Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 218

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Enhancing Source Camera Identification Performance With a Camera Reference Phase Sensor Pattern Noise

Kang, Xiangui, Li, Yinxiang, Qu, Zhenhua, Huang, Jiwu · 2012 · IEEE Transactions on Information Forensics and Security

Abstract

Sensor pattern noise (SPN) extracted from digital images has been proved to be a unique fingerprint of digital cameras. However, SPN can be contaminated largely in the frequency domain by image content and nonunique artefacts of JPEG compression, on-sensor signal transfer, sensor design, color interpolation. The source camera identification (CI) performance based on SPN needs to be improved for small sizes of images and especially in resisting JPEG compression. Because the SPN is modelled as an additive white Gaussian noise (AWGN) in its extraction process from an image, it is reasonable to assume the camera reference SPN to be a white noise signal in order to remove the interference mentioned above. The noise residues (SPN) extracted from the original images are whitened first, then they are averaged to generate the camera reference SPN. Motivated by Goljan 's test statistic peak to correlation energy (PCE), we propose to use correlation to circular correlation norm (CCN) as the test statistic, which can lower the false positive rate to be a half of that with PCE. Theoretical analysis shows that the proposed CI method can remove the interference and raise the CCN value of a positive sample and thus achieve greater CI performance, CCN values of the negative sample class with the proposed method follow the normal distributionN(0,1) and the false positive rate can be calculated. Compared with the existing state of the art on seven cameras, 1400 photos totally (200 for each camera), the experimental results show that the proposed CI method achieves the best receiver operating characteristic (ROC) performance among all CI methods in all cases and especially achieves much better resistance to JPEG compression than all of the existing state-of-the-art CI methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tifs.2011.2168214

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 218

Metadata

Authors
Kang, X., Li, Y., Qu, Z., & Huang, J.
Venue
IEEE Transactions on Information Forensics and Security
Published
2012-04
Volume
7
Issue
2
Pages
393-402
ISSN
  • 1556-6013 (ISSN-L)
  • 1556-6021
OpenAlex
W2086666872
Cited by
218
References
1
FWCI
11.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.