The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A High-Security EEG-Based Login System with RSVP Stimuli and Dry Electrodes
Abstract
Lately, electroencephalography (EEG)-based auth- entication has received considerable attention from the scientific community. However, the limited usability of wet EEG electrodes as well as low accuracy for large numbers of users have so far prevented this new technology to become commonplace. In this study a novel EEG-based authentication system is presented, which is based on the rapid serial visual presentation paradigm and uses a knowledge-based approach for authentication. Twenty-nine subjects’ data were recorded and analyzed with wet EEG electrodes as well as dry ones. A true acceptance rate of 100% can be reached for all subjects with an average required login time of 13.5 s for wet and 27 s for dry electrodes. Average false acceptance rates for the dry electrode setup were estimated to be$3.33 \times 10^{-5}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to biometric recognition
Jain, A. K., Ross, A., & Prabhakar, S. (2004) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2003.818349 · Cited by 4,974
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“troscopy (NIRS) [12], [13] and functional Magnetic Resonance Imaging (fMRI) [14], [15].”
BackgroundNeurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
Self-citationThe Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
Self-citation
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
EEG dataset and OpenBMI toolbox for three BCI paradigms: an investigation into BCI illiteracy
Lee, M.-H., Kwon, O.-Y., Kim, Y.-J., Kim, H.-K., Lee, Y.-E., Williamson, J., Fazli, S., & Lee, S.-W. (2019) · GigaScience · doi:10.1093/gigascience/giz002 · Cited by 590
Self-citationA survey on methods and challenges in EEG based authentication
Jalaly Bidgoly, A., Jalaly Bidgoly, H., & Arezoumand, Z. (2020) · Computers & Security · doi:10.1016/j.cose.2020.101788 · Cited by 173
Metadata
- Authors
- Chen, Y., Atnafu, A. D., Schlattner, I., Weldtsadik, W. T., Roh, M.-C., Kim, H. J., Lee, S.-W., Blankertz, B., & Fazli, S.
- Venue
- IEEE Transactions on Information Forensics and Security
- Published
- 2016-12
- Volume
- 11
- Issue
- 12
- Pages
- 2635-2647
- ISSN
- 1556-6013 (ISSN-L)
- 1556-6021
- OpenAlex
- W2416750880
- Cited by
- 165
- References
- 4
- FWCI
- 22.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A High-Security EEG-Based Login System with RSVP Stimuli and Dry Electrodes. https://app.cochat.ai/papers/10.1109/tifs.2016.2577551
- The paper
- Chen, Y., Atnafu, A. D., Schlattner, I., Weldtsadik, W. T., Roh, M.-C., Kim, H. J., Lee, S.-W., Blankertz, B., & Fazli, S. (2016). A High-Security EEG-Based Login System with RSVP Stimuli and Dry Electrodes. IEEE Transactions on Information Forensics and Security. https://doi.org/10.1109/tifs.2016.2577551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.