The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
LCL-Filter Design for Robust Active Damping in Grid-Connected Converters
Abstract
Grid-connected converters employ LCL-filters, instead of simple inductors, because they allow lower inductances while reducing cost and size. Active damping, without dissipative elements, is preferred to passive damping for solving the associated stability problems. However, large variations in the grid inductance may compromise system stability, and this problem is more severe for parallel converters. This situation, typical of rural areas with solar and wind resources, calls for robust LCL-filter design. This paper proposes a design procedure with remarkable results under severe grid inductance variation. The procedure considers active damping using lead-lag network and capacitor current feedback. Passive damping is also discussed. The design flow, with little iteration and no complex algorithms, selects the proper ratios between the switching and resonance frequency, the grid and converter inductance, and the filter capacitance and total inductance. An estimation for the grid current total harmonic distortion (THD) is also proposed. Simulation and experiments validate the proposals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Self-citationDesign and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
Self-citationLiserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Self-citationA new mathematical model and control of a three-phase AC-DC voltage source converter
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554176 · Cited by 871
Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter
Dannehl, J., Liserre, M., & Fuchs, F. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081952 · Cited by 648
Self-citationAgorreta, J. L., Borrega, M., López, J., & Marroyo, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095429 · Cited by 596
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568021 · Cited by 508
Distributed Generation: Toward a New Energy Paradigm
Guerrero, J., Blaabjerg, F., Zhelev, T., Hemmes, K., Monmasson, E., Jemei, S., Comech, M., Granadino, R., & Frau, J. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.935862 · Cited by 483
Self-citationGenetic Algorithm-Based Design of the Active Damping for an LCL-Filter Three-Phase Active Rectifier
Liserre, M., Dell'Aquila, A., & Blaabjerg, F. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820540 · Cited by 370
Self-citationKabir, M. N., Mishra, Y., Ledwich, G., Dong, Z. Y., & Wong, K. P. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2299336 · Cited by 362
Cited by
Chen, G., & Cai, X. (2018) · IEEE Access · doi:10.1109/access.2018.2789421 · Cited by 30
Metadata
- Authors
- Pena-Alzola, R., Liserre, M., Blaabjerg, F., Ordonez, M., & Yang, Y.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2014-11
- Volume
- 10
- Issue
- 4
- Pages
- 2192-2203
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2106652244
- Cited by
- 257
- References
- 18
- FWCI
- 23.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: LCL-Filter Design for Robust Active Damping in Grid-Connected Converters. https://app.cochat.ai/papers/10.1109/tii.2014.2361604
- The paper
- Pena-Alzola, R., Liserre, M., Blaabjerg, F., Ordonez, M., & Yang, Y. (2014). LCL-Filter Design for Robust Active Damping in Grid-Connected Converters. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2014.2361604
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.