The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A new mathematical model and control of a three-phase AC-DC voltage source converter
Abstract
A new mathematical model of the power circuit of a three-phase voltage source converter (VSC) was developed in the stationary and synchronous reference frames. The mathematical model was then used to analyze and synthesize the voltage and current control loops for the VSC. Analytical expressions were derived for calculating the gains and time constants of the current and voltage regulators. The mathematical model was used to control a 140-kW regenerative VSC. The synchronous reference-frame model was used to define feedforward signals in the current regulators to eliminate the cross coupling between the d and q phases. It allowed the reduction of the current control loops to first-order plants and improved their tracking capability. The bandwidths of the current and voltage-control loops were found to be approximately 20 and 60 times (respectively) smaller than the sampling frequency. All control algorithms were implemented in a digital signal processor. All results of the analysis were experimentally verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Electronics: Converters, Applications and Design
Mohan, N., Undeland, T. M., & Robbins, W. P. (1989) · Cited by 4,771
Leonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
A PWM AC-to-DC converter with fixed switching frequency
Wu, R., Dewan, S. B., & Slemon, G. R. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.60060 · Cited by 398
A Three-Phase Controlled-Current PWM Converter with Leading Power Factor
Ooi, B. T., Salmon, J. C., Dixon, J. W., & Kulkarni, A. B. (1987) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1987.4504869 · Cited by 225
Operation of a voltage source converter at increased utility voltage
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554178 · Cited by 66
Self-citation
Cited by
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines
Leon, A. E., & Solsona, J. A. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2327197 · Cited by 316
Genetic algorithm based design of the active damping for a LCL-filter three-phase active rectifier
Liserre, M., Dell'Aquila, A., & Blaabjerg, F. (2003) · Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03. · doi:10.1109/apec.2003.1179221 · Cited by 313
Suh, Y., & Lipo, T. A. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.873673 · Cited by 264
Metadata
- Authors
- Blasko, V., & Kaura, V.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 1997-01
- Volume
- 12
- Issue
- 1
- Pages
- 116-123
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2105449754
- Cited by
- 871
- References
- 5
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new mathematical model and control of a three-phase AC-DC voltage source converter. https://app.cochat.ai/papers/10.1109/63.554176
- The paper
- Blasko, V., & Kaura, V. (1997). A new mathematical model and control of a three-phase AC-DC voltage source converter. IEEE Transactions on Power Electronics. https://doi.org/10.1109/63.554176
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.