The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Enhanced quality-related fault detection approach based on OSC and M-PLS
Abstract
Partial least squares (PLS) is an efficient tool widely used in multivariate statistical process monitoring. Since standard PLS performs oblique projection to input space X, it has limitations in distinguishing quality-related and quality-unrelated faults. Several postprocessing modifications of PLS, such as total projection to latent structures (T-PLS), have been proposed to solve this issue. Further studies have found that these modifications fail to reduce false alarm rates (FARs) of quality-unrelated faults when fault amplitude increases. To cope with this problem, this paper proposes an enhanced quality-related fault detection approach based on orthogonal signal correction (OSC) and modified-PLS (M-PLS). The proposed approach removes variation orthogonal to output space Y from input space X before PLS modeling, and further decomposes X into two orthogonal subspaces in which quality-related and quality-unrelated statistical indicators are designed separately. Compared with T-PLS, the proposed approach has a more robust performance and a lower computational load. Two case studies, including a numerical example and the Tennessee Eastman (TE) process, show the effeteness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SIMPLS: An alternative approach to partial least squares regression
de Jong, S. (1993) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)85002-x · Cited by 1,905 · cited 1×
“In PLS, the following equations hold [13], [14]:”
BackgroundData-based techniques focused on modern industry: An overview
Yin, S., Li, X., Gao, H., & Kaynak, O. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2308133 · Cited by 1,025
Self-citation
Cited by
A Review on Recent Development of Spacecraft Attitude Fault Tolerant Control System
Yin, S., Xiao, B., Ding, S. X., & Zhou, D. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2530789 · Cited by 430
Self-citationDeep Coupling Autoencoder for Fault Diagnosis With Multimodal Sensory Data
Ma, M., Sun, C., & Chen, X. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2793246 · Cited by 304
Data-Driven Process Monitoring Based on Modified Orthogonal Projections to Latent Structures
Yin, S., Wang, G., & Gao, H. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2481318 · Cited by 258
Self-citation
Metadata
- Authors
- Wang, G., & Yin, S.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2015
- Pages
- 1-1
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W1845002809
- Cited by
- 162
- References
- 2
- FWCI
- 23.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced quality-related fault detection approach based on OSC and M-PLS. https://app.cochat.ai/papers/10.1109/tii.2015.2396853
- The paper
- Wang, G., & Yin, S. (2015). Enhanced quality-related fault detection approach based on OSC and M-PLS. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2015.2396853
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.