Efficient Control of Active Transformers for Increasing the PV Hosting Capacity of LV Grids
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The increased penetration of grid-connected photovoltaic (PV) systems in low-voltage (LV) grids creates concerns about overvoltage in these grids. The proposed methods to prevent overvoltage, such as reactive power absorption by PV inverters and active power management of customers, focus on decreasing the voltage rise along LV feeders, and the potential of active medium-voltage to low-voltage (MV/LV) transformers for overvoltage prevention has not been thoroughly investigated. This paper presents the application of active MV/LV transformers for increasing the PV hosting capacity of LV grids. The potential interferences between the operation of active transformers and the reactive power absorption by PV inverters are investigated, and a voltage droop control approach is proposed for the efficient control of these transformers during high PV generation periods. The proposed method can potentially increase the PV hosting capacity of the grid, while eliminating the need for a complex and centralized controller. The voltages of specific locations or the grid state estimations provide adequate data for adjustments of the droop parameters. The simulations and field test results associated with the implementation of the proposed method to a newly developed active LV grid with high PV penetration in Felsberg, Germany, confirm the efficiency of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of high PV penetration on voltage profiles in residential neighborhoods
Tonkoski, R., Turcotte, D., & El-Fouly, T. H. M. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2191425 · Cited by 557
Smart control for minimizing distribution network reinforcement cost due to electrification
Pudjianto, D., Djapic, P., Aunedi, M., Gan, C. K., Strbac, G., Huang, S., & Infield, D. (2013) · Energy Policy · doi:10.1016/j.enpol.2012.05.021 · Cited by 149
Hu, J., Marinelli, M., Coppo, M., Zecchino, A., & Bindner, H. W. (2016) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.10.025 · Cited by 66
Cited by
Koirala, A., Van Acker, T., D’hulst, R., & Van Hertem, D. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111899 · Cited by 118
Arshad, A., & Lehtonen, M. (2019) · IEEE Access · doi:10.1109/access.2019.2908725 · Cited by 66
“In [16], combination of OLTC and droop based RPC is applied, to enhance the HC of the urban LV network.”
A comprehensive solar PV hosting capacity in MV and LV radial distribution networks
Navarro, B. B., & Navarro, M. M. (2017) · 2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe) · doi:10.1109/isgteurope.2017.8260210 · Cited by 38
Ebe, F., Idlbi, B., Morris, J., Heilscher, G., & Meier, F. (2017) · 2017 IEEE Manchester PowerTech · doi:10.1109/ptc.2017.7981017 · Cited by 29
Metadata
- Authors
- Hashemi, S., Ostergaard, J., Degner, T., Brandl, R., & Heckmann, W.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2017-02
- Volume
- 13
- Issue
- 1
- Pages
- 270-277
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2538780405
- Cited by
- 64
- References
- 3
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient Control of Active Transformers for Increasing the PV Hosting Capacity of LV Grids. https://app.cochat.ai/papers/10.1109/tii.2016.2619065
- The paper
- Hashemi, S., Ostergaard, J., Degner, T., Brandl, R., & Heckmann, W. (2017). Efficient Control of Active Transformers for Increasing the PV Hosting Capacity of LV Grids. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2016.2619065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.