The DOI matches its Crossref record.
A Robust Load Frequency Control Scheme for Power Systems Based on Second-Order Sliding Mode and Extended Disturbance Observer
Abstract
This paper proposes a new robust load frequency control (LFC) scheme for multiarea power systems based on the second-order sliding mode control and an extended disturbance observer. First, a reduced-order model of the power system LFC is derived. In this model, the load variations and net exchange tie-line power deviations are combined as a lumped disturbance which can be estimated by the extended disturbance observer. Second, a novel sliding surface is designed with the new transformed state variables obtained from the estimated disturbance. The system dynamics can be indicated by sliding surface design using the eigenvalue assignment or the optimal sliding manifold technique. The sliding variable is driven to the sliding surface with a second-order sliding mode algorithm named supertwisting algorithm. The stability of the proposed LFC scheme and the extended disturbance observer is proved using Lyapunov method. The merits of the scheme include faster response speed, stronger robustness against disturbances arising from power system parameter errors, and unmodeled dynamics, and the full consideration of tie-line power flow scheduling variations. Finally, numerical simulations verify the effectiveness of the LFC scheme and reveal its advantages over the state of the arts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yan, Z., & Xu, Y. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2999890 · Cited by 398
Self-citationYan, Z., & Xu, Y. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2881359 · Cited by 387
Self-citationDistributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
Robust Load Frequency Control for Power System Considering Transmission Delay and Sampling Period
Shangguan, X.-C., Zhang, C.-K., He, Y., Jin, L., Jiang, L., Spencer, J. W., & Wu, M. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3026336 · Cited by 299
Wang, Q., Li, F., Tang, Y., & Xu, Y. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2919522 · Cited by 256
Self-citation
Metadata
- Authors
- Liao, K., & Xu, Y.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2018-07
- Volume
- 14
- Issue
- 7
- Pages
- 3076-3086
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2767509534
- Cited by
- 244
- References
- 0
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Robust Load Frequency Control Scheme for Power Systems Based on Second-Order Sliding Mode and Extended Disturbance Observer. https://app.cochat.ai/papers/10.1109/tii.2017.2771487
- The paper
- Liao, K., & Xu, Y. (2018). A Robust Load Frequency Control Scheme for Power Systems Based on Second-Order Sliding Mode and Extended Disturbance Observer. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2017.2771487
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.