A Noninvasive Blood Glucose Monitoring System Based on Smartphone PPG Signal Processing and Machine Learning
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Blood glucose level needs to be monitored regularly to manage the health condition of hyperglycemic patients. The current glucose measurement approaches still rely on invasive techniques which are uncomfortable and raise the risk of infection. To facilitate daily care at home, in this article, we propose an intelligent, noninvasive blood glucose monitoring system which can differentiate a user's blood glucose level into normal, borderline, and warning based on smartphone photoplethysmography (PPG) signals. The main implementation processes of the proposed system include 1) a novel algorithm for acquiring PPG signals using only smartphone camera videos; 2) a fitting-based sliding window algorithm to remove varying degrees of baseline drifts and segment the signal into single periods; 3) extracting characteristic features from the Gaussian functions by comparing PPG signals at different blood glucose levels; 4) categorizing the valid samples into three glucose levels by applying machine learning algorithms. Our proposed system was evaluated on a data set of 80 subjects. Experimental results demonstrate that the system can separate valid signals from invalid ones at an accuracy of 97.54% and the overall accuracy of estimating the blood glucose levels reaches 81.49%. The proposed system provides a reference for the introduction of noninvasive blood glucose technology into daily or clinical applications. This article also indicates that smartphone-based PPG signals have great potential to assess an individual's blood glucose level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354 · cited 1×
“It breaks down different waveforms into several different sub-waves [21], [22].”
BackgroundMonte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311 · cited 1×
“Hina [13] presented a non-invasive glucose monitoring prototype system composing of three main modules.”
BackgroundAn Explicit Description of the Reproducing Kernel Hilbert Spaces of Gaussian RBF Kernels
Steinwart, I., Hush, D., & Scovel, C. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.881713 · Cited by 240 · cited 1×
“Its matrix element is m kl , where l represents a binary SVM and k represents a data set category. g is the loss of decoding scheme. m l is the predicted score of the SVM l whose prediction result is chosen according to m kl [26].”
MethodWearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200 · cited 1×
“Rachim [15] collected PPG signals under different optical wavelengths by wearable biosensors.”
BackgroundBoloursaz Mashhadi, M., Asadi, E., Eskandari, M., Kiani, S., & Marvasti, F. (2016) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2509868 · Cited by 143 · cited 1×
“Photoplethysmography (PPG) technique has been applied to measure blood volume changes in certain parts of the body [7], [8].”
MethodPain-Free Blood Glucose Monitoring Using Wearable Sensors: Recent Advancements and Future Prospects
Siddiqui, S. A., Zhang, Y., Lloret, J., Song, H., & Obradovic, Z. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2822301 · Cited by 135 · cited 1×
“Currently, there is no effective treatment of diabetes, but regular monitoring of blood glucose level can reduce or delay the incidence of complications [2].”
BackgroundSelf-citationMotin, M. A., Karmakar, C. K., & Palaniswami, M. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2679108 · Cited by 128 · cited 1×
“Nabeel [9] realized non-invasive blood pressure measurement, and Motin [10] performed effective heart rate and respiratory rate monitoring.”
MethodLekha, S., & Suchetha, M. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2757510 · Cited by 123 · cited 1×
“[5].”
Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians
Rubīns, U. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0406-z · Cited by 98 · cited 1×
“Gaussian functionhas beenused to fit ear and finger PPG pulses [24].”
BackgroundPhotoplethysmography-Based Method for Automatic Detection of Premature Ventricular Contractions
Sološenko, A., Petrėnas, A., & Marozas, V. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2477437 · Cited by 88 · cited 1×
“In [19], feature extraction and heart rate calculation of PPG signals were performed using sliding window algorithm.”
Method
Research works printed but not linked: 2
- 10.1109/TBCAS.2013.2279103 · doi:10.1109/tbcas.2013.2279103
- 10.1109/JBHI.2014.2372047 · doi:10.1109/jbhi.2014.2372047
Cited by
Wearable Devices for Physical Monitoring of Heart: A Review
Prieto-Avalos, G., Cruz-Ramos, N. A., Alor-Hernández, G., Sánchez-Cervantes, J. L., Rodríguez-Mazahua, L., & Guarneros-Nolasco, L. R. (2022) · Biosensors · doi:10.3390/bios12050292 · Cited by 239
“The probability of suffering from these complications increases as the BG level increases and vice versa [65–68].”
BackgroundSmart Healthcare in the Age of AI: Recent Advances, Challenges, and Future Prospects
Nasr, M., Islam, M. M., Shehata, S., Karray, F., & Quintana, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3118960 · Cited by 236
“Zhang et al. [24] proposed a framework for blood glucose monitoring using PhotoPlethysmoGram (PPG) data in the form of a video from a smartphone.”
MethodNoninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator
Abdolrazzaghi, M., Katchinskiy, N., Elezzabi, A. Y., Light, P. E., & Daneshmand, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090050 · Cited by 207
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Susana, E., Ramli, K., Murfi, H., & Apriantoro, N. H. (2022) · Information · doi:10.3390/info13020059 · Cited by 59
Metadata
- Authors
- Zhang, G., Mei, Z., Zhang, Y., Ma, X., Lo, B., Chen, D., & Zhang, Y.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2020-11
- Volume
- 16
- Issue
- 11
- Pages
- 7209-7218
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W3007406359
- Cited by
- 172
- References
- 25
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Funders
- National Natural Science Foundation of China (61572231, 61572110)
- Newton Fund Researcher Links Workshop (2017-RLWK9-11046)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.