Optimized Design of Parity Relation-Based Residual Generator for Fault Detection: Data-Driven Approaches
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In the conventional approaches to the design of fault diagnosis systems, little effort is usually paid to the selection of the parity vectors. As a result, the systems' performance can be significantly affected. In this article, novel approaches are proposed to derive the parity vectors that construct optimized residual generators for linear and nonlinear systems. Based on the analysis on the parity space dimension, a novel parameterization of all parity relation-based residual generators is proposed. An iterative procedure that guarantees minimal regression error is then employed in the search for the optimal parameters. Considering that the traditional parity relation-based approaches are only suitable for linear systems, in this work, the proposed approach is also generalized to deal with strong nonlinearities, with the aid of data-driven Hammerstein function estimation. Furthermore, optimized residual generation algorithms are summarized for offline design and online implementation, the performance of which is evaluated thoroughly with a three-tank system, a numerical nonlinear example, as well as a case study on an industrial hot rolling mill process. Results show that residuals generated by the proposed approaches can significantly improve the sensitivity to small faults, and thus, the fault detection rate is improved compared with the traditional nonoptimized approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Chadli, M., & Karimi, H. R. (2013) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2012.2197215 · Cited by 388 · cited 1×
“For this purpose, design approaches in [32] and [33] would provide good foundations.”
RetractedGao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
A review of process fault detection and diagnosis
Venkatasubramanian, V., Rengaswamy, R., Yin, K., & Kavuri, S. N. (2003) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00160-6 · Cited by 2,723
(2012) · IEEE Control Systems · doi:10.1109/mcs.2012.2214134 · Cited by 1,105 · cited 1×
“To deal with process dynamics, successful solutions were proposed based on the state space models [6]–[8], the machine learning techniques [9], [10], as well as the dynamic modifications of the MVA data structures [11].”
MethodGao, Z., Cecati, C., & Ding, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2419013 · Cited by 776 · cited 1×
“To deal with process dynamics, successful solutions were proposed based on the state space models [6]–[8], the machine learning techniques [9], [10], as well as the dynamic modifications of the MVA data structures [11].”
MethodData-driven Design of Fault Diagnosis and Fault-tolerant Control Systems
Ding, S. X. (2014) · Advances in Industrial Control · doi:10.1007/978-1-4471-6410-4 · Cited by 669 · cited 4×
“Due to practical constraints, some industrial applications demand that the fault diagnosis systems should be designed and implemented in the data-driven framework [15]–[17].”
BackgroundMethodInfluentialSubspace-based methods for the identification of linear time-invariant systems
Viberg, M. (1995) · Automatica · doi:10.1016/0005-1098(95)00107-5 · Cited by 615
Nonlinear Dynamic Process Monitoring Using Canonical Variate Analysis and Kernel Density Estimations
Odiowei, P.-E. P., & Cao, Y. (2010) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2009.2032654 · Cited by 361 · cited 1×
“To deal with process dynamics, successful solutions were proposed based on the state space models [6]–[8], the machine learning techniques [9], [10], as well as the dynamic modifications of the MVA data structures [11].”
MethodSubspace method aided data-driven design of fault detection and isolation systems
Ding, S. X., Zhang, P., Naik, A., Ding, E. L., & Huang, B. (2009) · Journal of Process Control · doi:10.1016/j.jprocont.2009.07.005 · Cited by 312 · cited 2×
“In recent years, the intimate relationship between the parity vectors and the diagnostic observers was revealed [14].”
BackgroundReal-time fault diagnosis and fault-tolerant control
Gao, Z., Ding, S. X., & Cecati, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417511 · Cited by 308
Chen, H., Jiang, B., Lu, N., & Mao, Z. (2018) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2818538 · Cited by 190 · cited 1×
“Numerous multivariate statistical analysis (MVA)-based approaches applicable to the static processes have been developed [3]–[5].”
BackgroundDing, S. X., Yang, Y., Zhang, Y., & Li, L. (2014) · Automatica · doi:10.1016/j.automatica.2014.08.022 · Cited by 187 · cited 2×
“To this end, basic data-driven approaches were proposed in [18] to identify the parity vectors directly from the historical data independent of explicit state space models.”
BackgroundMethodData-driven Detection and Diagnosis of Incipient Faults in Electrical Drives of High-Speed Trains
Chen, H., Jiang, B., Chen, W., & Yi, H. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2863191 · Cited by 171 · cited 1×
“As a key component of process monitoring and life cycle management, fault diagnosis systems have attracted continuous attention over the past several decades [1], [2].”
BackgroundLiu, X., Gao, Z., & Zhang, A. (2019) · Automatica · doi:10.1016/j.automatica.2018.12.031 · Cited by 92 · cited 1×
“For this purpose, design approaches in [32] and [33] would provide good foundations.”
Ding, J., Modares, H., Chai, T., & Lewis, F. L. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2516973 · Cited by 83 · cited 1×
“However, most of the studies are focused on the numerical approximation of the parity vectors without proper optimization procedures[21].”
BackgroundGrbovic, M., Li, W., Xu, P., Usadi, A. K., Song, L., & Vučetić, S. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.02.003 · Cited by 82 · cited 1×
“Numerous multivariate statistical analysis (MVA)-based approaches applicable to the static processes have been developed [3]–[5].”
BackgroundA Distributed Fault Detection System Based on IWSN for Machine Condition Monitoring
Neužil, J., Kreibich, O., & Šmíd, R. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2290432 · Cited by 78 · cited 1×
“To deal with process dynamics, successful solutions were proposed based on the state space models [6]–[8], the machine learning techniques [9], [10], as well as the dynamic modifications of the MVA data structures [11].”
MethodMnassri, B., Adel, E. M. E., & Ouladsine, M. (2015) · Journal of Process Control · doi:10.1016/j.jprocont.2015.06.004 · Cited by 73
A Two-Stage Fault Detection and Isolation Platform for Industrial Systems Using Residual Evaluation
Heydarzadeh, M., & Nourani, M. (2016) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2016.2575179 · Cited by 65
Peng, K., Zhang, K., You, B., & Dong, J. (2015) · IET Control Theory and Applications · doi:10.1049/iet-cta.2014.0732 · Cited by 40 · cited 1×
“In the rolling mill system, numerous sensors are installed to collect the measurements [29], [30].”
BackgroundRecursive subspace system identification for parametric fault detection in nonlinear systems
Gil, P. S., Santos, F., Palma, L. B., & Cardoso, A. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2015.08.036 · Cited by 20 · cited 1×
“A series of enhanced approaches were proposed to improve the computational efficiency [13], to suppress the measurement noise and unknown disturbances (for offline design), and to improve the adaptivity and robustness against model uncertainties (for online implementation).”
Background
Cited by
A Review on Soft Sensors for Monitoring, Control, and Optimization of Industrial Processes
Jiang, Y., Yin, S., Dong, J., & Kaynak, O. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3033153 · Cited by 667
Self-citationQuo vadis artificial intelligence?
Jiang, Y., Li, X., Luo, H., Yin, S., & Kaynak, O. (2022) · Discover Artificial Intelligence · doi:10.1007/s44163-022-00022-8 · Cited by 544
Self-citationA Fault Diagnosis Method for Quadruped Robot Based on Hybrid Deep Neural Networks
Wang, Z., Li, H., Chen, Z., & Han, Q.-L. (2025) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3523534 · Cited by 29
Metadata
- Authors
- Jiang, Y., Yin, S., & Kaynak, O.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2021-02
- Volume
- 17
- Issue
- 2
- Pages
- 1449-1458
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W3017198169
- Cited by
- 185
- References
- 21
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.