Cited by 27Prosthetics and Rehabilitation RoboticsMuscle activation and electromyography studiesRobotic Locomotion and Control

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

A Function Approximator Model for Robust Online Foot Angle Trajectory Prediction Using a Single IMU Sensor: Implication for Controlling Active Prosthetic Feet

Open access
Dey, Sharmita, Schilling, Arndt F.·2023·IEEE Transactions on Industrial Informatics

Abstract

Lower limb dysfunction hinders the locomotive activity in individuals and compels them to use assistive devices such as prostheses or orthoses to restore the missing locomotive functions. Passive assistive devices have limitations in replacing the lost functionality. On the other hand, active devices could restore more natural locomotion using motorized joints. To make proper use of these embedded motors, a control architecture is required to translate the motion intent of the user into the intended prosthesis joint trajectories. In this article, we propose a temporal convolution-based online foot angle trajectory prediction network (FATP-N) that predicts the foot angular positions during unconstrained walking from the shank angular position measured using a single wearable motion tracker sensor. The data acquisition experiments were designed to reflect natural gait with turns, varying inclines, speeds, and mixed cadences. The trained models were prepared for real-time prediction by compressing them to reduce the storage and time complexity. The validations were performed on different motion conditions, including those that have not been used for model training, to verify the robustness of the model. The proposed FATP-N achieved high accuracy and could generate predictions in real time. The results indicate that the proposed approach offers a possible architecture for real-time control of powered intelligent prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tii.2022.3158935

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Research works printed but not linked: 1

  1. shuangfeng, 2020, Tensorflow lite: On-device machine learning framework, J Comput Res Develop, 57

Cited by

Sorted by citations

Metadata

Authors
Dey, S., & Schilling, A. F.
Affiliations
Universitätsmedizin Göttingen (DE)
Venue
IEEE Transactions on Industrial Informatics
Published
2023-02
Volume
19
Issue
2
Pages
1467-1475
ISSN
  • 1551-3203 (ISSN-L)
  • 1941-0050
OpenAlex
W4226336393
Cited by
27
References
26
Citations by year
2026: 2 · 2025: 9 · 2024: 6 · 2023: 9
FWCI
1.82
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Industrial Informatics (publishedVersion, cc-by)
  • GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (submittedVersion, cc-by)
  • GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (submittedVersion, other-oa)
Funders
German Federal Ministry of Education and Research (INOPRO16SV7657)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Locomotion and Control
Keywords
lower limb prosthesis, temporal convolutional network, online prediction, real-time control, gait, model compression

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review