The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Near-Field-Sensing Transceiver for Intrabody Communication Based on the Electrooptic Effect
Abstract
This paper describes a near-field-sensing transceiver for intrabody communication, in which the human body is the transmission medium. The key component of the transceiver is an electric-field sensor implemented with an electrooptic crystal and laser light. This sensor is suitable for detection of the small and unstable electric fields produced by the human body because it has extremely high input impedance. This transceiver enables IEEE 802.3 half-duplex communication of 10 Mb/s through a person's body in an operating range of about 150 cm between the hands. The packet error rate of 0.04% is obtained at packet size of 1070 octet. This paper explains the configuration and performance of the transceiver and presents results of a communication test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Computer for the 21st Century
Weiser, M. (1991) · Scientific American · doi:10.1038/scientificamerican0991-94 · Cited by 10,017
Cited by
The Human Body Characteristics as a Signal Transmission Medium for Intrabody Communication
Cho, N., Yoo, J., Song, S.-J., Lee, J., Jeon, S., & Yoo, H.-J. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895640 · Cited by 355
Ultralow-Power Electronics for Biomedical Applications
Chandrakasan, A. P., Verma, N., & Daly, D. C. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160547 · Cited by 285
The Signal Transmission Mechanism on the Surface of Human Body for Body Channel Communication
Bae, J., Cho, H., Song, K., Lee, H., & Yoo, H.-J. (2012) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2011.2178857 · Cited by 282
Zhang, K., Hao, Q., Song, Y., Wang, J., Huang, R., & Liu, Y. (2014) · Sensors · doi:10.3390/s140101740 · Cited by 33
Metadata
- Authors
- Shinagawa, M., Fukumoto, M., Ochiai, K., & Kyuragi, H.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2004-12
- Volume
- 53
- Issue
- 6
- Pages
- 1533-1538
- ISSN
- 0018-9456 (ISSN-L)
- OpenAlex
- W2114979750
- Cited by
- 200
- References
- 1
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.