Cited by 33Wireless Body Area NetworksMolecular Communication and NanonetworksNeuroscience and Neural Engineering

Modeling and characterization of the implant intra-body communication based on capacitive coupling using a transfer function method

Open access
Zhang, Kai, Hao, Qun, Song, Yong, Wang, Jingwen, Huang, Ruobing, Liu, Yue·2014·Sensors

Abstract

Implantable devices have important applications in biomedical sensor networks used for biomedical monitoring, diagnosis and treatment, etc. In this paper, an implant intra-body communication (IBC) method based on capacitive coupling has been proposed, and the modeling and characterization of this kind of IBC has been investigated. Firstly, the transfer function of the implant IBC based on capacitive coupling was derived. Secondly, the corresponding parameters of the transfer function are discussed. Finally, both measurements and simulations based on the proposed transfer function were carried out, while some important conclusions have been achieved, which indicate that the achieved transfer function and conclusions are able to help to achieve an implant communication method with the highly desirable characteristics of low power consumption, high data rate, high transmission quality, etc.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s140101740

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The operating frequency range for implant intra-body communication (IBC) is typically between 3 and 10 MHz, but can vary depending on the specific application and circuit design.

    “Beyond SAR, it is crucial to consider the operating frequency range, which for implant intra-body communication (IBC) is typically between 3 and 10 MHz. However, this range can vary depending on the specific application and circuit design, further emphasizing the need for optimal parameter selection (Zhang et al., 2014).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Zhang et al., 2014

    The Experiments and Discussion section reports relatively low, stable attenuation at 3–10 MHz for the paper’s proposed capacitive-coupling method. It does not establish that 3–10 MHz is the typical operating range for implant IBC generally, or that the range varies by application and circuit design; the study measured frequencies from 100 kHz to 40 MHz (page not specified in our copy). (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 32 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Zhang, K., Hao, Q., Song, Y., Wang, J., Huang, R., & Liu, Y.
Affiliations
Beijing Institute of Technology (CN)
Corresponding author
  • Hao, Qun
  • Song, Yong
Venue
Sensors
Publisher
MDPI AG
Published
2014-01-20
Volume
14
Issue
1
Pages
1740-1756
ISSN
1424-8220 (ISSN-L)
OpenAlex
W1992533865
Cited by
33
References
32
Citations by year
2025: 2 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 6 · 2017: 5 · 2016: 3 · 2014: 1
FWCI
1.56
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Biomedical Engineering › Molecular Communication and Nanonetworks
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
capacitive coupling, transfer function, biomedical implants, biomedical sensor networks, low power consumption, high-speed data transmission, transmission quality
MeSH terms
Humans, Telemetry, Biosensing Techniques, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review