BNM-SYRTE Fountains: Recent Results
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Recent improvements of Bureau National de Me/spl acute/trologie Syste/spl grave/mes de Re/spl acute/fe/spl acute/rence Temps Espace (BNM-SYRTE) fountains FO1 and FO2 are described. Fractional frequency instabilities of 2.9/spl times/10/sup -14//spl tau//sup -1/2/ for FO1 and 1.6/spl times/10/sup -14//spl tau//sup -1/2/ for FO2 have been demonstrated. A preliminary estimate of the systematic frequency shifts gives an uncertainty of /spl plusmn/7.2/spl times/10/sup -16/ for FO1 and /spl plusmn/6.5/spl times/10/sup -16/ for FO2. Furthermore, we present a direct comparison between the two fountains. When a real-time measurement of the collisional shift is included, we observe a stability of the comparison of 5.0/spl times/10/sup -14//spl tau//sup -1/2/ and a frequency difference of /spl delta/=4/spl times/10/sup -16/, well within the combined uncertainties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298 · cited 1×
“Furthermore, ultra precise atomic clocks constitute an excellent tool for fundamental physics experiments, such as the test of the time variation of fundamental constants [5], [6].”
MethodSelf-citation
Cited by
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Atomic clocks based on coherent population trapping: a review
Vanier, J. (2005) · Applied Physics B · doi:10.1007/s00340-005-1905-3 · Cited by 669
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationCold atom clocks and applications
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Santos, F. P. D., Rosenbusch, P., et al. (2005) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/38/9/002 · Cited by 239
Self-citation
Metadata
- Authors
- Vian, C., Rosenbusch, P., Marion, H., Bize, S., Cacciapuoti, L., Zhang, S., Abgrall, M., Chambon, D., Maksimovic, I., Laurent, P., Santarelli, G., Clairon, A., Luiten, A., Tobar, M., & Salomon, C.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2005-04
- Volume
- 54
- Issue
- 2
- Pages
- 833-836
- ISSN
- 0018-9456 (ISSN-L)
- OpenAlex
- W2141822540
- Cited by
- 95
- References
- 1
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BNM-SYRTE Fountains: Recent Results. https://app.cochat.ai/papers/10.1109/tim.2005.843573
- The paper
- Vian, C., Rosenbusch, P., Marion, H., Bize, S., Cacciapuoti, L., Zhang, S., Abgrall, M., Chambon, D., Maksimovic, I., Laurent, P., Santarelli, G., Clairon, A., Luiten, A., Tobar, M., & Salomon, C. (2005). BNM-SYRTE Fountains: Recent Results. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2005.843573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.