The DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Progress in atomic fountains at LNE-SYRTE
Open accessAbstract
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the (87)Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
The Confrontation between General Relativity and Experiment
Will, C. M. (2006) · Living Reviews in Relativity · doi:10.12942/lrr-2006-3 · Cited by 1,606
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“The accuracy and stability of optical atomic clocks have now largely surpassed those of microwave clocks, and notably atomic fountain clocks [88][89][90][91].”
BackgroundPohl, R., Antognini, A., Nez, F., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Fernandes, L. M. P., et al. (2010) · Nature · doi:10.1038/nature09250 · Cited by 1,374
The fundamental constants and their variation: observational and theoretical status
Uzan, J.-P. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.403 · Cited by 1,162
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Varying Constants, Gravitation and Cosmology
Uzan, J.-P. (2011) · Living Reviews in Relativity · doi:10.12942/lrr-2011-2 · Cited by 740
Research works printed but not linked: 29
- 10.1109/FCS.2011.5977825 · doi:10.1109/fcs.2011.5977825
- 10.1051/epjap:2007072 · doi:10.1051/epjap:2007072
- 10.1109/FREQ.2009.5168204 · doi:10.1109/freq.2009.5168204
- 10.1109/19.918181 · doi:10.1109/19.918181
- grop, 2010, ELISA: A cryocooled 10 GHz oscillator with 10?15 frequency stability, Rev Sci Itistrum, 81
- 10.1109/TUFFC.2010.1515 · doi:10.1109/tuffc.2010.1515
- 10.1103/PhysRevA.71.063401 · doi:10.1103/physreva.71.063401
- rosenbusch, 2007, Blackbody radiation shift in primary frequency standards, Proc Joint 21st Eur Frequency Time Forum IEEE Int Frequency Control Symp, 1060
- 10.1103/PhysRevA.75.042505 · doi:10.1103/physreva.75.042505
- 10.1088/0370-1328/92/4/303 · doi:10.1088/0370-1328/92/4/303
- 10.1209/epl/i2006-10383-2 · doi:10.1209/epl/i2006-10383-2
- guéna, 2011, Quantitative evaluation of distributed cavity phase shifts to improve the accuracy of SYRTE F02, IEEE Int Frequency Control Symp & European Frequency and Time Forum Proc, 61
- press, 1992, Numerical Recipes in C, 663
- 10.1109/TIM.2010.2088430 · doi:10.1109/tim.2010.2088430
- 2004, Recommendation CCTF-1 2004 Concerning Secondary Representations of the Second BIPM-CCTF 2004, 38
- 10.1109/FCS.2011.5977321 · doi:10.1109/fcs.2011.5977321
- 10.1103/PhysRevA.74.023405 · doi:10.1103/physreva.74.023405
- 10.1007/s100500050167 · doi:10.1007/s100500050167
- 10.1007/s00340-006-2396-6 · doi:10.1007/s00340-006-2396-6
- 10.1109/FCS.2011.5977854 · doi:10.1109/fcs.2011.5977854
- guillemot, 2008, Time transfer by laser link-T2L2: An opportunity to calibrate RF links, Proceedings of the Precise Time and Time Interval Meeting, 95
- 10.1088/0026-1394/48/5/N04 · doi:10.1088/0026-1394/48/5/n04
- 10.1038/nature05680 · doi:10.1038/nature05680
- 10.1088/0026-1394/48/5/N03 · doi:10.1088/0026-1394/48/5/n03
- 10.1063/1.1634359 · doi:10.1063/1.1634359
- 10.1109/FCS.2011.5977842 · doi:10.1109/fcs.2011.5977842
- 10.1139/cjp-78-7-639 · doi:10.1139/cjp-78-7-639
- 10.1109/58.656627 · doi:10.1109/58.656627
- 10.1088/0026-1394/45/6/S07 · doi:10.1088/0026-1394/45/6/s07
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Self-citation
Metadata
- Authors
- Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., Gibble, K., Clairon, A., & Bize, S.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2012-03
- Volume
- 59
- Issue
- 3
- Pages
- 391-409
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2148106425
- Cited by
- 291
- References
- 103
- FWCI
- 17.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progress in atomic fountains at LNE-SYRTE. https://app.cochat.ai/papers/10.1109/tuffc.2012.2208
- The paper
- Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., Gibble, K., Clairon, A., & Bize, S. (2012). Progress in atomic fountains at LNE-SYRTE. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2012.2208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.