Characterization of a Completely User-Independent Algorithm for Carotid Artery Segmentation in 2-D Ultrasound Images
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The analysis of the carotid artery wall is crucial for the diagnosis of serious cardiovascular pathologies or for the assessment of a subject's cardiovascular risk. Several algorithms have been proposed for the segmentation of ultrasound carotid artery images, but almost all require a certain degree of user interaction. We recently developed a completely user-independent algorithm for the segmentation of the common-carotid-artery wall; specifically, the algorithm traces the contour of the interfaces between the lumen and the intima layer and between the media and adventitia layers. In this paper, we show the characterization of the algorithm in terms of segmentation error. Moreover, we compare the output of the algorithm with the segmentations manually traced by four experts, using the percent statistics test and testing the automatically generated segmentation against the average human segmentations. We show that our algorithm's segmentation is not statistically different from that of a trained operator and that the segmentation error is lower than 1 pixel for both the lumen-intima interface and for the media-adventitia interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001 · cited 1×
“Details, implementations, and extensions of this algorithm can be found in [10].”
A methodology for evaluation of boundary detection algorithms on medical images
Chalana, V., & Kim, Y. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640755 · Cited by 542 · cited 3×
“The Percent Statistics Algorithm for the evaluation of contour extraction was first proposed by Chalana and Kim [11] and later improved by Alberola-López et al. [12].”
MethodInfluentialTouboul, P.-J., Elbaz, A., Koller, C., Lucas, C., Adraï, V., Chédru, F., Amarenco, P., & Investigators, F. T. G. (2000) · Circulation · doi:10.1161/01.cir.102.3.313 · Cited by 270
Incidence of stroke is related to carotid IMT even in the absence of plaque
Rosvall, M., Janzon, L., Berglund, G., Engström, G., & Hedblad, B. (2005) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2004.10.015 · Cited by 211 · cited 1×
“Interestingly, the IMT is related to brain infarction even in the absence of carotid plaque [3]; this”
BackgroundCheng, D.-C., Schmidt-Trucksäss, A., Cheng, K.-S., & Burkhardt, H. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00149-8 · Cited by 166 · cited 2×
“oped operator-dependent techniques [6], [7], and it is slightly”
BackgroundMethodAutomatic measurement of carotid diameter and wall thickness in ultrasound images
Gutierrez, M. A., Pilon, P. E., Lage, S. G., Kopel, L., de Carvalho, R. T., & Furuie, S. S. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166783 · Cited by 83 · cited 4×
“Similarly, the user has to select the portion of the image containing the carotid artery wall in the technique by Gutierrez [7].”
BackgroundMethodInfluentialWhat does intima???media thickness tell us?
Bortel, L. M. V. (2005) · Journal of Hypertension · doi:10.1097/00004872-200501000-00009 · Cited by 79
Comments on: A methodology for evaluation of boundary detection algorithms on medical images
Alberola‐López, C., Martín‐Fernández, M., & Ruiz‐Alzola, J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.826358 · Cited by 53
Gustavsson, T., Rafeef Abugharbieh, A., Hamarneh, G., & Liang, Q. (1997) · Computers in cardiology · doi:10.1109/cic.1997.647832 · Cited by 44 · cited 2×
“better than that of some other segmentation approaches [4], [5].”
BackgroundMethodSIMONE, G. D., McClelland, R. L., Gottdiener, J. S., Celentano, A., Kronmal, R. A., & Gardin, J. M. (2001) · Journal of Hypertension · doi:10.1097/00004872-200110000-00026 · Cited by 37
CULEX-Completely User-independent Layers EXtraction: Ultrasonic Carotid Artery Images Segmentation
Delsanto, S., Molinari, F., Giustetto, P., Liboni, W., & Badalamenti, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615980 · Cited by 35 · cited 1×
“layers extraction (CULEX) algorithm for the segmentation of the distal border of the CCA [8].”
MethodSelf-citation
Cited by
The present and future of deep learning in radiology
Saba, L., Biswas, M., Kuppili, V., Cuadrado Godia, E., Suri, H. S., Edla, D. R., Omerzu, T., Laird, J. R., Khanna, N. N., Mavrogeni, S., et al. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.02.038 · Cited by 353
Self-citationMolinari, F., Zeng, G., & Suri, J. S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.04.007 · Cited by 222
Self-citationSuri, J. S., Agarwal, S., Jena, B., Saxena, S., El-Baz, A., Agarwal, V., Kalra, M. K., Saba, L., Viskovic, K., Fatemi, M., et al. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3174270 · Cited by 38
Self-citation
Metadata
- Authors
- Delsanto, S., Molinari, F., Giustetto, P., Liboni, W., Badalamenti, S., & Suri, J. S.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2007-08
- Volume
- 56
- Issue
- 4
- Pages
- 1265-1274
- ISSN
- 0018-9456 (ISSN-L)
- OpenAlex
- W2133774886
- Cited by
- 160
- References
- 11
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.