The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Autocalibration of MEMS Accelerometers
Abstract
In this paper, we present a novel procedure for the on-the-field autocalibration of triaxial micro accelerometers, which requires neither any equipment nor a controlled environment and allows increasing the accuracy of this kind of microsensor. The procedure exploits the fact that, in static conditions, the modulus of the accelerometer output vector matches that of the gravity acceleration. The calibration model incorporates the bias and scale factor for each axis and the cross-axis symmetrical factors. The parameters are computed through nonlinear optimization, which is solved in a very short time. The calibration procedure was quantitatively tested by comparing the orientation produced by MEMS with that measured by a motion capture system. Results show that the MEMS output, after the calibration procedure, is far more accurate with respect to the output obtained using factory calibration data and almost one order of magnitude more accurate with respect to using traditional calibration models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple View Geometry in Computer Vision
Hartley, R., & Zisserman, A. (2004) · doi:10.1017/cbo9780511811685 · Cited by 21,070
Cited by
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267
ColloSSL: Collaborative Self-Supervised Learning for Human Activity Recognition
Jain, Y., Tang, C. I., Min, C., Kawsar, F., & Mathur, A. (2022) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3517246 · Cited by 113
A Mobile Motion Capture System Based on Inertial Sensors and Smart Shoes
Jung, P.-G., Oh, S., Lim, G., & Kong, K. (2014) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.4025207 · Cited by 44
Joint Angle Measurement Using Strategically Placed Accelerometers and Gyroscope
Vikas, V., & Crane, C. D. (2016) · Journal of Mechanisms and Robotics · doi:10.1115/1.4031299 · Cited by 15
Metadata
- Authors
- Frosio, I., Pedersini, F., & Borghese, N. A.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2009-06
- Volume
- 58
- Issue
- 6
- Pages
- 2034-2041
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2983921147
- Cited by
- 194
- References
- 1
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Autocalibration of MEMS Accelerometers. https://app.cochat.ai/papers/10.1109/tim.2008.2006137
- The paper
- Frosio, I., Pedersini, F., & Borghese, N. A. (2009). Autocalibration of MEMS Accelerometers. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2008.2006137
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.