Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We describe the design, fabrication, and evaluation of a new on-wafer measurement platform for the rapid and quantitative determination of the complex permittivity of nanoliter fluid volumes over the continuous frequency range from 45 MHz to 40 GHz. Our measurement platform integrates micrometer-scale poly(dimethylsiloxane) (PDMS)-based microfluidic channels with high-frequency coplanar waveguide (CPW) transmission lines to accurately place small fluid volumes at well-defined locations within planar measurement structures. We applied new on-wafer calibration techniques to accurately determine the scattering parameters of our integrated devices, and we developed a transmission-line model to extract the distributed circuit parameters of the fluid-loaded transmission line segment from the response of the overall test structure. All the necessary model parameters were experimentally determined directly from a single set of measurements without requiring a reference fluid of known permittivity. We extracted the complex permittivity of the fluid under test from the distributed capacitance and conductance per unit length of the fluid-loaded transmission line segment using finite-element analysis of the transmission line cross section. Our measurements show excellent agreement with bulk fluid permittivity determinations for methanol at room temperature and yield consistent results for the extracted fluid permittivity for the same microfluidic channel embedded in multiple CPW transmission lines of different dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152 · cited 1×
“To further understand our results for the relative permittivity of PDMS, we fit our frequency-dependent permittivity data to the Cole‐Cole function [ 46 ], which gives the following expression for the complex relative permittivity:”
MethodThe origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Zeck, G., & Fromherz, P. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181348698 · Cited by 290
Cited by
Water‐Resonator‐Based Metasurface: An Ultrabroadband and Near‐Unity Absorption
Song, Q., Zhang, W., Wu, P. C., Zhu, W., Shen, Z. X., Chong, P. H. J., Liang, Q. X., Yang, Z. C., Hao, Y. L., Cai, H., et al. (2017) · Advanced Optical Materials · doi:10.1002/adom.201601103 · Cited by 156
Metadata
- Authors
- Booth, J. C., Orloff, N. D., Mateu, J., Janezic, M., Rinehart, M., & Beall, J. A.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-12
- Volume
- 59
- Issue
- 12
- Pages
- 3279-3288
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2145355122
- Cited by
- 172
- References
- 3
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz. https://app.cochat.ai/papers/10.1109/tim.2010.2047141
- The paper
- Booth, J. C., Orloff, N. D., Mateu, J., Janezic, M., Rinehart, M., & Beall, J. A. (2010). Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2010.2047141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.