CoChat

Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz

Booth, James C., Orloff, Nathan D., Mateu, Jordi, Janezic, Michael, Rinehart, Matthew, Beall, James A. · 2010 · IEEE Transactions on Instrumentation and Measurement
Cited by 172

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We describe the design, fabrication, and evaluation of a new on-wafer measurement platform for the rapid and quantitative determination of the complex permittivity of nanoliter fluid volumes over the continuous frequency range from 45 MHz to 40 GHz. Our measurement platform integrates micrometer-scale poly(dimethylsiloxane) (PDMS)-based microfluidic channels with high-frequency coplanar waveguide (CPW) transmission lines to accurately place small fluid volumes at well-defined locations within planar measurement structures. We applied new on-wafer calibration techniques to accurately determine the scattering parameters of our integrated devices, and we developed a transmission-line model to extract the distributed circuit parameters of the fluid-loaded transmission line segment from the response of the overall test structure. All the necessary model parameters were experimentally determined directly from a single set of measurements without requiring a reference fluid of known permittivity. We extracted the complex permittivity of the fluid under test from the distributed capacitance and conductance per unit length of the fluid-loaded transmission line segment using finite-element analysis of the transmission line cross section. Our measurements show excellent agreement with bulk fluid permittivity determinations for methanol at room temperature and yield consistent results for the extracted fluid permittivity for the same microfluidic channel embedded in multiple CPW transmission lines of different dimensions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2010.2047141

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 172

Metadata

Authors
Booth, J. C., Orloff, N. D., Mateu, J., Janezic, M., Rinehart, M., & Beall, J. A.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2010-12
Volume
59
Issue
12
Pages
3279-3288
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2145355122
Cited by
172
References
3
FWCI
6.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz. https://app.cochat.ai/papers/10.1109/tim.2010.2047141
The paper
Booth, J. C., Orloff, N. D., Mateu, J., Janezic, M., Rinehart, M., & Beall, J. A. (2010). Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2010.2047141

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.