Inchoate Fault Detection Framework: Adaptive Selection of Wavelet Nodes and Cumulant Orders
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Inchoate fault detection for machine health monitoring (MHM) demands high level of fault classification accuracy under poor signal-to-noise ratio (SNR) which persists in most industrial environment. Vibration signals are extensively used in signature matching for abnormality detection and diagnosis. In order to guarantee improved performance under poor SNR, feature extraction based on statistical parameters which are immune to Gaussian noise becomes inevitable. This paper proposes a novel framework for adaptive feature extraction based on higher order cumulants (HOCs) and wavelet transform (WT) (AFHCW) for MHM. Features extracted based on HOCs have the tendency to mitigate the impact of Gaussian noise. WT provides better time and frequency domain analysis for the nonstationary signals such as vibration in which spectral contents vary with respect to time. In AFHCW, stationary WT is used to ensure linear processing on the vibration data prior to feature extraction, and it helps in mitigating the impact of poor SNR. K-nearest neighbor classifier is used to categorize the type of the fault. Simulation studies show that the proposed scheme outperforms the existing techniques in terms of classification accuracy under poor SNR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the VC-Dimension of a Learning Machine
Vapnik, V., Levin, E., & Cun, Y. L. (1994) · Neural Computation · doi:10.1162/neco.1994.6.5.851 · Cited by 388
Cited by
Artificial intelligence for fault diagnosis of rotating machinery: A review
Liu, R., Yang, B., Zio, E., & Chen, X. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.02.016 · Cited by 2,188
Wavelets for fault diagnosis of rotary machines: A review with applications
Yan, R., Gao, R. X., & Chen, X. (2014) · Signal Processing · doi:10.1016/j.sigpro.2013.04.015 · Cited by 1,446
From Model, Signal to Knowledge: A Data-Driven Perspective of Fault Detection and Diagnosis
Dai, X., & Gao, Z. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2243743 · Cited by 728
A generic intelligent bearing fault diagnosis system using compact adaptive 1D CNN classifier
Eren, L., Ince, T., & Kiranyaz, S. (2019) · Journal of Signal Processing Systems · doi:10.1007/s11265-018-1378-3 · Cited by 723
Peng, T., Shen, C., Sun, S., & Wang, D. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3111567 · Cited by 76
Metadata
- Authors
- Yaqub, M. F., Gondal, I., & Kamruzzaman, J.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2012-03
- Volume
- 61
- Issue
- 3
- Pages
- 685-695
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2112601224
- Cited by
- 71
- References
- 1
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inchoate Fault Detection Framework: Adaptive Selection of Wavelet Nodes and Cumulant Orders. https://app.cochat.ai/papers/10.1109/tim.2011.2172112
- The paper
- Yaqub, M. F., Gondal, I., & Kamruzzaman, J. (2012). Inchoate Fault Detection Framework: Adaptive Selection of Wavelet Nodes and Cumulant Orders. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2011.2172112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.