The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ECG Signal Analysis Using DCT-Based DOST and PSO Optimized SVM
Abstract
Signal processing techniques are an obvious choice for real-time analysis of electrocardiography (ECG) signals. However, classical signal processing techniques are unable to deal with the nonstationary nature of the ECG signal. In this context, this paper presents a new approach, i.e., discrete orthogonal stockwell transform using discrete cosine transform for efficient representation of the ECG signal in time-frequency space. These time-frequency features are further reduced in lower dimensional space using principal component analysis, representing the morphological characteristics of the ECG signal. In addition, the dynamic features (i.e., RR-interval information) are computed and concatenated to the morphological features to constitute the final feature set, which is utilized to classify the ECG signals using support vector machine (SVM). In order to improve the classification performance, particle swarm optimization technique is employed for gradually tuning the learning parameters of the SVM classifier. In this paper, ECG data exhibiting 16 classes of the most frequently occurring arrhythmic events are taken from the benchmark MIT-BIH arrhythmia database for the validation of the proposed methodology. The experimental results yielded an improved overall accuracy, sensitivity (Sp), and positive predictivity (Pp) of 98.82% in comparison with the existing approaches available in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Cited by
Particle Swarm Optimization Algorithm and Its Applications: A Systematic Review
Gad, A. G. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09694-4 · Cited by 1,869
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Major Advances in Particle Swarm Optimization: Theory, Analysis, and Application
Houssein, E. H., Gad, A. G., Hussain, K., & Suganthan, P. N. (2021) · Swarm and Evolutionary Computation · doi:10.1016/j.swevo.2021.100868 · Cited by 466
RetractedLSTM-Based Auto-Encoder Model for ECG Arrhythmias Classification
Hou, B., Yang, J., Wang, P., & Yan, R. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2910342 · Cited by 307
Recycling waste classification using optimized convolutional neural network
Mao, W.-L., Chen, W.-C., Wang, C.-T., & Lin, Y.-H. (2021) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2020.105132 · Cited by 278
Metadata
- Authors
- Raj, S., & Ray, K. C.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2017-03
- Volume
- 66
- Issue
- 3
- Pages
- 470-478
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2568858846
- Cited by
- 243
- References
- 1
- FWCI
- 16.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG Signal Analysis Using DCT-Based DOST and PSO Optimized SVM. https://app.cochat.ai/papers/10.1109/tim.2016.2642758
- The paper
- Raj, S., & Ray, K. C. (2017). ECG Signal Analysis Using DCT-Based DOST and PSO Optimized SVM. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2016.2642758
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.