The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Sensitive SPR Biosensor Based on Graphene Oxide and Staphylococcal Protein A Co-Modified TFBG for Human IgG Detection
Abstract
A highly sensitive optical fiber surface plasmon resonance (SPR) biosensor based on graphene oxide (GO) and staphylococcal protein A (SPA) co-modified tilted fiber Bragg grating (TFBG) is proposed and demonstrated for the detection of human immunoglobulin G (IgG) for the first time. The gold film on the surface of the sensor was first fixed with GO and then modified with an SPA to improve the sensitivity of the sensor. Large specific surface area and abundant functional groups of GO can adsorb more antibodies. The combination of SPA and the antibody molecule Fc region makes the Fab area with antigen-binding sites extend outward, resulting in highly oriented antibody immobilization on the sensor surface and high antigen-antibody binding efficiency. The experimental results show that the sensitivity as well as the limit of detection of GO-SPA-modified TFBG-SPR biosensor is around 0.096 dB/($\mu \text{g}$ /mL) and $0.5~\mu \text{g}$ /mL, showing better responses to human IgG solutions with a concentration range of 30-$100~\mu \text{g}$ /mL compared with the TFBG-SPR biosensors modified singly with GO or SPA. The biosensor exhibits the advantages of small size, ease of fabrication, high sensitivity, label-free, and rapid response, and provides a new solution for detecting low concentration of biological solution, presenting great application potential in the biochemistry field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shi, S., Wang, L., Su, R., Liu, B., Huang, R., Qi, W., & He, Z. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.080 · Cited by 174
Cited by
Research advances on surface plasmon resonance biosensors
Wang, Q., Ren, Z.-H., Zhao, W.-M., Wang, L., Yan, X., Zhu, A.-S., Qiu, F.-M., & Zhang, K.-K. (2022) · Nanoscale · doi:10.1039/d1nr05400g · Cited by 267
Self-citationRecent Advancements of LSPR Fiber‐Optic Biosensing: Combination Methods, Structure, and Prospects
Zhang, H., Zhou, X., Li, X., Gong, P., Zhang, Y., & Zhao, Y. (2023) · Biosensors · doi:10.3390/bios13030405 · Cited by 99
“There are some detection principles of fiber-optic biosensors, such as localized surface plasmon resonance (LSPR) [8], interference [9,10], whispering gallery mode (WGM) [11], surface plasmon resonance (SPR) [12,13], etc.”
Background
Metadata
- Authors
- Wang, Q., Jing, J.-Y., & Wang, B.-T.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2019-09
- Volume
- 68
- Issue
- 9
- Pages
- 3350-3357
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2900206772
- Cited by
- 183
- References
- 1
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.