A polydopamine-modified optical fiber SPR biosensor using electroless-plated gold films for immunoassays

Shi, Se, Wang, Libing, Su, Rongxin, Liu, Boshi, Huang, Renliang, Qi, Wei, He, Zhimin·2015·Biosensors and Bioelectronics

Abstract

A sensitive and stable electroless-plated gold film for the preparation of an optical fiber surface plasmon resonance (SPR) sensor is presented in this work, together with a facile antibody immobilization method. Gold nanoparticles were uniformly adsorbed onto the surface of an optical fiber forming a film with a thickness of approximately 56.3 nm. The sensor had a high sensitivity with 2054 nm/RIU and 3980 nm/RIU in the refractive index ranges of 1.333-1.359 and 1.359-1.386, respectively. An SPR biosensor was developed based on polydopamine-modified gold film (PDA-Au), which was fabricated by a simple and quick spontaneous polymerization of dopamine (DA) on the gold film. When goat anti-human IgG antibodies were immobilized, the PDA-Au surface had a larger resonant wavelength shift of 66.21 nm compared with the traditional 11-mercaptoundecanoic acid-modified gold film (MUA-Au) surface. In addition, the PDA-Au surface enabled the sensitive and selective determination of human IgG down to a concentration of 2 μg mL(-1) with a high sensitivity of 0.41 nm per μg mL(-1). The PDA-Au surface exhibited an approximately four fold higher sensitivity and an about seven fold lower LOD than the MUA-Au surface to human IgG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2015.06.080

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 40

  1. Cao, 2013, Sens. Actuators B: Chem., 181, 611, 10.1016/j.snb.2013.02.052 · DOI
  2. Dmitriev, 2008, Nano Lett., 8, 3893, 10.1021/nl8023142 · DOI
  3. Flavel, 2009, Electrochim. Acta, 54, 3191, 10.1016/j.electacta.2008.11.055 · DOI
  4. Grabar, 1996, Langmuir, 12, 2353, 10.1021/la950561h · DOI
  5. Hatab, 2010, Nano Lett., 10, 4952, 10.1021/nl102963g · DOI
  6. Honda, 2005, Biosens. Bioelectron., 20, 2306, 10.1016/j.bios.2004.11.007 · DOI
  7. Huang, 2013, Sens. Actuators B: Chem., 186, 199, 10.1016/j.snb.2013.06.008 · DOI
  8. Karakouz, 2009, Chem. Mater., 21, 5875, 10.1021/cm902676d · DOI
  9. Kim, 2012, Anal. Chem., 84, 4784, 10.1021/ac300336h · DOI
  10. Ko, 2009, Biosens. Bioelectron., 24, 2592, 10.1016/j.bios.2009.01.030 · DOI
  11. LaVoie, 2005, Nat. Med., 11, 1214, 10.1038/nm1314 · DOI
  12. Lee, 2009, Adv. Mater., 21, 431, 10.1002/adma.200801222 · DOI · Paper page
  13. Lee, 2006, Proc. Natl. Acad. Sci. USA, 103, 12999, 10.1073/pnas.0605552103 · DOI · Paper page
  14. Li, 2013, Biosens. Bioelectron., 41, 809, 10.1016/j.bios.2012.10.021 · DOI
  15. Liu, 2014, Nanoscale, 6, 13145, 10.1039/C4NR04301D · DOI
  16. Liu, 2014, ACS Appl. Mater. Interfaces, 6, 13034, 10.1021/am502921z · DOI
  17. Liu, 2014, Chem. Rev., 114, 5057, 10.1021/cr400407a · DOI · Paper page
  18. Maisonneuve, 2015, Biosens. Bioelectron., 63, 80, 10.1016/j.bios.2014.06.018 · DOI
  19. Muench, 2012, J. Mater. Chem., 22, 12784, 10.1039/c2jm31110k · DOI
  20. Navarrete, 2010, Plasmonics, 5, 7, 10.1007/s11468-009-9108-0 · DOI
  21. Perez-Ruiz, 2014, Anal. Chem., 86, 3084, 10.1021/ac404107s · DOI
  22. Pollet, 2009, Biosens. Bioelectron., 25, 864, 10.1016/j.bios.2009.08.045 · DOI
  23. Prodan, 2003, Science, 302, 419, 10.1126/science.1089171 · DOI
  24. Sciacca, 2014, Langmuir, 30, 946, 10.1021/la403667q · DOI
  25. Sharma, 2007, IEEE Sens. J., 7, 1118, 10.1109/JSEN.2007.897946 · DOI
  26. Shevchenko, 2014, Biosens. Bioelectron., 56, 359, 10.1016/j.bios.2014.01.018 · DOI
  27. Suzuki, 2008, Sens. Actuators B: Chem., 132, 26, 10.1016/j.snb.2008.01.003 · DOI
  28. Tabakman, 2011, Small, 7, 499, 10.1002/smll.201001836 · DOI
  29. Tu, 2014, Sens. Actuators B: Chem, 191, 37, 10.1016/j.snb.2013.09.094 · DOI
  30. Verma, 2015, Food Chem., 166, 568, 10.1016/j.foodchem.2014.06.045 · DOI
  31. Wan, 2011, Biosens. Bioelectron., 26, 2595, 10.1016/j.bios.2010.11.013 · DOI
  32. Wang, 2013, Food Chem., 136, 1303, 10.1016/j.foodchem.2012.09.069 · DOI
  33. Wong, 2013, IEEE J. Sel. Top. Quantum Electron., 19
  34. Yang, 2014, Anal. Chem., 86, 3227, 10.1021/ac500381e · DOI
  35. Zabetakis, 2009, ACS Appl. Mater. Interfaces, 1, 4, 10.1021/am800121d · DOI
  36. Zangmeister, 2013, Langmuir, 29, 8619, 10.1021/la400587j · DOI
  37. Zhang, 2013, Small, 9, 2537, 10.1002/smll.201202958 · DOI
  38. Zhang, 2013, Analyst, 138, 7175, 10.1039/c3an01553j · DOI
  39. Zhao, 2015, Biosens. Bioelectron., 64, 664, 10.1016/j.bios.2014.09.082 · DOI
  40. Zhao, 2014, Sens. Actuators B: Chem., 192, 229, 10.1016/j.snb.2013.10.108 · DOI

Metadata

Authors
Shi, S., Wang, L., Su, R., Liu, B., Huang, R., Qi, W., & He, Z.
Affiliations
Tianjin University (CN)
Corresponding author
Su, Rongxin
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2015-12
Volume
74
Pages
454-460
ISSN
0956-5663 (ISSN-L)
OpenAlex
W776384419
Cited by
174
References
2
Citations by year
2026: 7 · 2025: 19 · 2024: 20 · 2023: 10 · 2022: 26 · 2021: 14 · 2020: 18 · 2019: 14 · 2018: 16 · 2017: 13 · 2016: 15 · 2015: 2
FWCI
7.39
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (21276192, 51473115)
  • Ministry of Education of the People's Republic of China (B06006, NCET-11-0372)
  • Ministry of Science and Technology of the People's Republic of China (2012AA06A303, 2012BAD29B05, 2012YQ090194)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Plasmonic and Surface Plasmon Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
Keywords
surface plasmon resonance biosensor, fiber optic sensors, polydopamine, gold nanoparticles, antibody immobilization, human IgG detection, immunoassay, 11-mercaptoundecanoic acid, refractive index sensitivity
MeSH terms
Electrodes, Equipment Design, Fiber Optic Technology, Gold, Immunoassay, Indoles, Membranes, Artificial, Polymers, Equipment Failure Analysis, Coated Materials, Biocompatible, Surface Plasmon Resonance, Metal Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review