1-pT Noise Fluxgate Magnetometer for Geomagnetic Measurements and Unshielded Magnetocardiography
Open accessThe DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
Abstract
We present the development of a low-noise, fundamental-mode, orthogonal fluxgate magnetometer with four amorphous, annealed ferromagnetic wires. The 1-Hz noise obtained in the open and closed loop is as low as 0.75 and 1.5 pTrms/$\surd $Hz, respectively, with the white noise level about 0.6 pTrms/$\surd $Hz. This is to the best of our knowledge the lowest figure published for a fluxgate magnetometer so far. By using the annealed sensor cores, we also found the offset drift to decrease approximately six times to 2.5 nT/K. We compared the instrument performance to a low-noise observatory magnetometer when doing geomagnetic measurements and show that it is fully suitable for measurements at mHz frequencies, e.g., magnetotellurics. The magnetometer performance enables room-temperature, unshielded magnetocardiography. With a gradiometric arrangement of two sensors, we were able to perform an MCG measurement in ambient field, and even without averaging, the signal could be clearly resolved.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Magnetotelluric Method: Theory and Practice
(2012) · Cambridge University Press eBooks · doi:10.1017/cbo9781139020138 · Cited by 702 · cited 1×
“They are used at geomagnetic observatories [1], for navigation and prospection [2], attitude correction, and scientific experiments in aerospace [3], in magnetotellurics [4], [5], nondestructive testing and evaluation [6], nanoparticle detection [7], and in other subjects where vectorial response to magnetic fields an…”
BackgroundDetection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Alem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/12/4797 · Cited by 182
Orthogonal fluxgate mechanism operated with dc biased excitation
Sasada, I. (2002) · Journal of Applied Physics · doi:10.1063/1.1451899 · Cited by 123 · cited 1×
“They were introduced by Sasada in 2001 [15] and since then the parameters have continuously improved – the noise decreased from the initial 10 pT down to about 1.5-2 pT rms / √ Hz for laboratory devices [17]; with the help of core annealing, sub-pT noise was reported recently [18].”
InfluentialMiniaturized digital fluxgate magnetometer for small spacecraft applications
Forslund, Å., Belyayev, S., Ivchenko, N., Olsson, G., Edberg, T., & Marusenkov, A. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/19/1/015202 · Cited by 64 · cited 1×
“They are used at geomagnetic observatories [1], for navigation and prospection [2], attitude correction and scientific experiments in aerospace [3], in magnetotellurics [4][5], non-destructive testing and evaluation [6], nanoparticle detection [7] and in other subjects, where vectorial response to…”
Flux-Gate Magnetometers Design Peculiarities
Korepanov, V. E., & Marusenkov, A. (2012) · Surveys in Geophysics · doi:10.1007/s10712-012-9197-8 · Cited by 55 · cited 1×
“As for parallel-type fluxgates, the state-of-the art magnetometers exhibit noise level about 3-4 pT rms / √ Hz at 1 Hz [9][11][12].”
BackgroundLow-noise flux-gate magnetic-field sensors using ring- and rod-core geometries
Koch, R. H., & Rozen, J. R. (2001) · Applied Physics Letters · doi:10.1063/1.1358852 · Cited by 54 · cited 1×
“1-pT noise was obtained with cross-correlation measurements and special sensor arrangement in [13], however the principle was not exploited any further.”
MethodReduction of Noise in Fundamental Mode Orthogonal Fluxgates by Optimization of Excitation Current
Butta, M., Yamashita, S., & Sasada, I. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2152379 · Cited by 43 · cited 2×
“Overview of applications of 1-pT level sensors - from [16] We have to state that the generally accepted disadvantage of fundamental-mode fluxgates is their offset-drift - about 50 nT/K was shown in [17].”
BackgroundInfluentialSelf-citationDependence of sensitivity and noise of fluxgate sensors on racetrack geometry
Hinnrichs, C., Stahl, J., Kuchenbrandt, K., & Schilling, M. (2001) · IEEE Transactions on Magnetics · doi:10.1109/20.951028 · Cited by 40
Research works printed but not linked: 6
- technlogies, 2018, General Geophysical Devices
- pappas, 2008, High Sensitivity Magnetic Field Sensor Technology Overview
- hong, 2016, The temperature stability of LeMI-025 1-second variometer: Case study in the icheon observatory, J Indian Geophys Union, 2, 42
- pedersen, 2016, The FGE magnetometer and the INTERMAGNET 1 second standard, J Ind Geophys Union, 2, 30
- 2018, AD24USB/AD24ETH—Data Acquisition Modules
- 2019, Noise Reduction in AD24USB
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Many efforts have been made to develop such kinds of mag-netometers, such as the induction coil magnetometer ( 28 ), fluxgate magnetometers ( 29 ), and magnetoresistive magnetometers ( 30 , 31 ).”
Recent Progress of Fluxgate Magnetic Sensors: Basic Research and Application
Wei, S., Liao, X., Zhang, H., Pang, J., & Zhou, Y. (2021) · Sensors · doi:10.3390/s21041500 · Cited by 123
“The arrangement of the MCG measurement is shown in Figure 4 [25].”
BackgroundMethodInfluentialQuantitative Evaluation for Magnetoelectric Sensor Systems in Biomagnetic Diagnostics
Elzenheimer, E., Bald, C., Engelhardt, E., Hoffmann, J., Hayes, P., Arbustini, J., Bahr, A., Quandt, E., Höft, M., & Schmidt, G. U. (2022) · Sensors · doi:10.3390/s22031018 · Cited by 67
“magnetometers [3,4], xMR sensors [5], orthogonal fluxgates [6], and many more.”
BackgroundSQUIDs for magnetic and electromagnetic methods in mineral exploration
Stolz, R., Schiffler, M., Becken, M., Thiede, A., Schneider, M., Chubak, G., Marsden, P., Bergshjorth, A. B., Schaefer, M. O., & Terblanche, O. (2022) · Mineral Economics · doi:10.1007/s13563-022-00333-3 · Cited by 65
Exchange biased surface acoustic wave magnetic field sensors
Schell, V., Spetzler, E., Wolff, N., Bumke, L., Kienle, L., McCord, J., Quandt, E., & Meyners, D. (2023) · Scientific Reports · doi:10.1038/s41598-023-35525-6 · Cited by 39
Zhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
Fabrication Advancements in Integrated Fluxgate Sensors: A Mini Review
Savarapu, R., Sohan, A., & Kollu, P. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202101040 · Cited by 27
Quantum-Enhanced Sensing with Squeezed Light: From Fundamentals to Applications
Heng, X., Zhang, L., Yin, Q., Liu, W., Tang, L., Zhai, Y., & Wei, K. (2025) · Applied Sciences · doi:10.3390/app151810179 · Cited by 27
Sensitivity and noise of parallel fluxgate sensor with amorphous wire cores
Hrakova, D., Ripka, P., & Butta, M. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2022.169981 · Cited by 21
Self-citationXie, H., Zhang, R., Zhang, Z., Ai, Y., Deng, J., Chen, Y., Zhou, Y., Li, M., Liu, L., Gao, M., et al. (2024) · International Journal of Mining Science and Technology · doi:10.1016/j.ijmst.2023.12.004 · Cited by 21
Key Metrics and Experimental Test Bench for Assessing Highly Sensitive Magnetometers in Research
Elzenheimer, E., Knappe-Grüneberg, S., Zerfowski, J., Evans, W., Grüneberg, F., Höft, M., Soekadar, S. R., Robinson, S. E., & Voigt, J. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3491164 · Cited by 24
Zhao, W., Tao, X., Ye, C., & Tao, Y. (2022) · Sensors · doi:10.3390/s22031021 · Cited by 21
“They demonstrated the applicability of the instrument [16].”
BackgroundOptically pumped magnetometer with dynamic common mode magnetic field compensation
Wang, Y., Niu, Y., & Ye, C. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.113195 · Cited by 17
Reduction of magnetic noise limits of orthogonal fluxgate sensor
Dressler, M., Janošek, M., & Butta, M. (2021) · AIP Advances · doi:10.1063/9.0000231 · Cited by 16
Self-citationA Benchmark of Integrated Magnetometers and Magnetic Gradiometers
Brajon, B., Gasparin, E., & Close, G. F. (2023) · IEEE Access · doi:10.1109/access.2023.3325035 · Cited by 18
“In addition, discrete magnetic transducers are relatively bulky with respect to chip-scale dimensions, like in the discrete fluxgate [40] and GMI sensor [33].”
BackgroundMethodDevelopment of a high-sensitivity orthogonal fluxgate sensor
Priftis, P., Angelopoulos, S., Ktena, A., & Hristoforou, E. V. (2023) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2023.171646 · Cited by 14
Miniature Wide-Range Three-Axis Vector Atomic Magnetometer
Li, J., Yicheng, D., Wang, X., Lu, H., & Liu, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3112522 · Cited by 14
Yan, B., Zhu, W., Zhuang, X., Lu, Z., & Fang, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3086904 · Cited by 12
“5 pT/ √ Hz with a closed-loop design [9], [10].”
Study of Nonlinear Excitation Circuits for Fluxgate Magnetometer
Zhang, C., Zhang, Y., Wang, X., & Meng, H. (2023) · Sensors · doi:10.3390/s23052618 · Cited by 10
MEMS Fluxgate Sensor Based on Liquid Casting
Yang, Y., Xu, W., Chen, G., Jin, Z., Wang, D., Mai, Z., Xing, G., & Chen, J. (2023) · Micromachines · doi:10.3390/mi14122159 · Cited by 10
Bedside Magnetocardiography with a Scalar Sensor Array
Iwata, G. Z., Nguyen, C. T., Tharratt, K., Ruf, M., Reinhardt, T., Crivelli-Decker, J. E., Liddy, M. S. Z., Rugar, A. E., Lu, F., Aschbacher, K., et al. (2024) · Sensors · doi:10.3390/s24165402 · Cited by 12
“However, demonstrations of sensitivity required for MCG have only been limited to proof-of-concept experiments [27–29].”
BackgroundDependence of the noise of an orthogonal fluxgate on the composition of its amorphous wire-core
Butta, M., Vázquez, M., del Real, R. P., & Calle, E. (2020) · AIP Advances · doi:10.1063/1.5130393 · Cited by 10
Self-citationOptimization of U-shaped Cu@ Fe20Ni80 core for orthogonal fluxgate sensor
Pu, X., Zhou, Q., Chai, G., & Gao, D. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.171822 · Cited by 9
Single-board low-noise fluxgate magnetometer
Dyer, T., Griffin, P. F., & Riis, E. (2024) · Journal of Applied Physics · doi:10.1063/5.0175418 · Cited by 8
Inkjet-printed Mn-Zn ferrite nanoparticle core for fluxgate
Hrakova, D., Ripka, P., Laposa, A., Novotny, D., Kroutil, J. C., Povolný, V., Kaman, O., & Veverka, P. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2022.170003 · Cited by 8
“these devices is 1 pT/Hz at 1 Hz [4].”
BackgroundSelf-citationYan, B., Zhu, W., Sun, Y. P., Lu, Z., Zhuang, X., & Fang, G. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3363619 · Cited by 8
“A lot of studies have shown that the heat treatment can change, to some extent, the magnetic properties of amorphous wires, so it is expected that the thermal annealing process on the magnetic core can improve the noise performance of the sensor [22], [23], [24], [25], [26].”
BackgroundAriannik, M., Rezaei‐Zare, A., & Werle, P. W. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3024908 · Cited by 8
Enhancing linearity of open-loop parallel fluxgate sensors via induced anisotropy in amorphous wires
Mu, C., Pan, L., Ma, H., Su, M., He, A., Dong, Y., Man, Q., Li, D., & Li, J. (2025) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2025.180636 · Cited by 6
An Improved Composition of CoFeSiB Alloy for Orthogonal Fluxgates
Butta, M., Janošek, M., Pařez, J., Inchausti, A. V., & Chiriac, H. (2022) · Sensors · doi:10.3390/s22062162 · Cited by 6
“The whole electronic of the magnetometer [14] has an input-referred noise of 7 nV/ √ Hz at 1 Hz at the working frequency: in the worst case scenario (10 kV/T), this corresponds to 0.”
BackgroundSelf-citationCorodeanu, S., Hlenschi, C., Chiriac, H., Lupu, N., & Óvári, T.-A. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3487069 · Cited by 5
“The excitation and pickup configuration of the proposed RTD sensor is similar with the one used for traditional orthogonal fluxgate sensor based on amorphous wires [17], [18].”
Demagnetization Effect in a Meander-Core Orthogonal Fluxgate Sensor
Zhi, S., Sun, X., Zhang, Q., Chen, J., Zhang, X., Chen, H., & Lei, C. (2021) · Micromachines · doi:10.3390/mi12080937 · Cited by 5
“[27] reported that the noise level of an orthogonal fluxgate based on amorphous wire core reached 1 pT/ √ Hz at 1 Hz, but the maximum linear range was 12 μT, and the length of the core was more than 800 mm.”
BackgroundA Symmetrical Quartz-Based Magnetoelectric Sensor for Pico-Tesla Magnetic Field Detection
Sun, C., Yang, W. R., & Zhang, Y. (2022) · Symmetry · doi:10.3390/sym14102130 · Cited by 5
“Though the fluxgate can achieve a lower noise level and attain a high magnetic field detection ability, the size is larger and fabrication process is more complex than that of the ME sensor [19].”
BackgroundOffset drift in orthogonal fluxgate and importance of closed-loop operation
Butta, M., Dressler, M., & Janošek, M. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113583 · Cited by 5
Self-citationAn Automatic Loop Gain Enhancement Technique in Magnetoimpedance-Based Magnetometer
Akita, I., Kawano, T., Aoyama, H., Tatematsu, S., & Hioki, M. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3202224 · Cited by 5
“[9], [10] have achieved few pT/ √ Hz-level noise floor for”
BackgroundSun, C., Liang, Y., Yang, X., Zhao, B., Zhang, P., Liu, S., Yang, D., Wu, T., Zhang, J., & Guo, H. (2024) · iScience · doi:10.1016/j.isci.2024.110167 · Cited by 5
Multiferroic magnetoelectric-based biosensors in healthcare
Sahini, M. G., & Malima, N. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21658-9.00025-5 · Cited by 5
Performance of Fluxgate Magnetometer with Cu-Doped CoFeSiB Amorphous Microwire Core
Wang, B., Zheng, X., Sida, J., Yi, Z., Huang, B., Wang, P., Tian, Y., & Tang, X. (2024) · Sensors · doi:10.3390/s24010309 · Cited by 4
“Notably, CoFeSiB amorphous microwires cores have reduced the noise of fundamental mode orthogonal fluxgates (FM-OFG) to an impressive 750 fT/ √ Hz [1], matching the noise level of superconducting quantum interference devices (SQUIDs).”
BackgroundThe apparent permeability and the amplification factor of magnetic wires and wire arrays
Ripka, P., Grim, V., & Mirzaei, M. (2021) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.167726 · Cited by 4
Design, fabrication and characterisation of a three-axis, ring-core fluxgate magnetometer
Mosahebfard, A., Daneshmandi, O., Hosseinzadeh, A., Abdi, M., & Yazdjerdy, M. (2021) · Pramana · doi:10.1007/s12043-021-02150-9 · Cited by 4
Precise Measurement of Magnetic Field for Geophysical, Space, and Security Applications
Lipovský, P., Ripka, P., Draganová, K., & Polakovič, A. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3570654 · Cited by 4
Orthogonal fluxgate sensor noise depends on annealing-induced magnetostriction of the core
Butta, M., Inchausti, A. V., Dressler, M., & Janošek, M. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639470 · Cited by 3
“Orthogonal fluxgates in fundamental mode [1÷5] have been proven capable to measure very small magnetic field such as in magnetocardiography [6] where peaks of 10÷20 pT generated by human hearth are detected.”
BackgroundSelf-citationGudoshnikov, S. A., Danilov, G., Gorelikov, E. S., Grebenshchikov, Y. B., Odintsov, V., & Venediktov, S. N. (2022) · Measurement · doi:10.1016/j.measurement.2022.112045 · Cited by 3
Low-Temperature Properties of the Magnetic Sensor with Amorphous Wire
He, D., Umemori, K., Ueki, R., Dohmae, T., Okada, T., Tachiki, M., Ooi, S., & Watanabe, M. (2020) · Sensors · doi:10.3390/s20236986 · Cited by 3
Pu, X., Yu, Z., Gao, J., Zhong, M., Wang, L., Xiao, W., Chai, G., & Gao, D. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116899 · Cited by 3
High-temperature digital circuit design for fluxgate sensor
Zhang, C., Zhang, Y., Gao, J., & Li, Z. (2022) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2196/1/012015 · Cited by 2
Online Monitoring of Magnetometer Signals for Estimating Induced Electric Fields in Power Systems
Ariannik, M., & Rezaei‐Zare, A. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3188203 · Cited by 2
Noise in Single-Core Gradiometers Based on Orthogonal Fluxgate
Dressler, M., & Butta, M. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3387101 · Cited by 2
“The electronic circuit used as a switched demodulator is described in [1] and a separate low-noise preamplifier board placed in close proximity to the sensor is introduced in [19].”
MethodSelf-citationDesign and Development of a Coaxial Integrated Triaxial Fluxgate Sensor
Zhao, Z., Hou, Y., Luo, C., & Shi, J. (2024) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2024.3472227 · Cited by 2
“F LUXGATE sensors are commonly used in geomagnetic field monitoring [1], space survey [2], celestial observation [3], geomagnetic navigation [4], current detection [5], and many other fields due to their high sensitivity and quick response.”
A Low Conductivity Medium Detection Module Based on Magnetoelectric Sensors
Qiu, Y., Zhong, Q., Zhou, Y., An, J., Li, Y., Song, A., Wang, J., Yu, G., Zhu, M., Wu, Y., et al. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3561443 · Cited by 2
“The minimum magnetic field detection limit of fluxgate sensors is close to 1 pT, but their bandwidth is only several tens of kilohertz [25].”
Liu, W., Xu, X., Zhao, Z., Wang, L., & Wu, W. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3591833 · Cited by 2
“However, environmental magnetic noise (MN) (e.g., geomagnetic field fluctuations and electromagnetic interference) is often significantly stronger than the target signals, severely a ff ecting MEG measurement accuracy and posing a major bottleneck for its broader application [3], [4], [5].”
Magnetic Noise of Flux Gates and Magnetic Modulation Sensors with an Amorphous Ferromagnetic Core
Сокол-Кутыловский, О. Л. (2021) · Instruments and Experimental Techniques · doi:10.1134/s0020441221050110 · Cited by 2
Сокол-Кутыловский, О. Л. (2022) · Izvestiya VUZ Applied Nonlinear Dynamics · doi:10.18500/0869-6632-2022-30-2-233-238 · Cited by 2
Yi, G., Li, Y., Li, Y., Liu, X., Dong, X., & Gao, X. (2025) · Sensors · doi:10.3390/s25010234 · Cited by 3
“…superconducting quantum interference devices (SQUIDs) and spin-exchange relaxation-free (SERF) magnetometers have gained widespread use in fields such as magnetoencephalography (MEG) [1–5] and magnetocardiography (MCG) [6–10] due to their non-destructive properties and exceptional sensitivity.”
Yan, B., Zhu, W., Zhuang, X., Lu, Z., & Fang, G. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3652552 · Cited by 1
“…, a 2 , a 1 , and a 0 are determined by circuit parameters (such as To determine the stability of the system, we apply the Routh–Hurwitz criterion [23], [24], [25], which provides necessary and sufficient conditions for the roots of the characteristic equation to lie in the left half of the…”
Enhanced SAW magnetic sensing via acoustic energy confinement of high-order harmonics
Sun, Z., Du, W., Chen, C., Xie, S., Ma, M., Tao, D., Liu, P., Xiao, B., Wang, H., An, S., et al. (2026) · Applied Physics Letters · doi:10.1063/5.0339542 · Cited by 1
Ultralow Noise Orthogonal Fluxgates Enabling Weak Magnetic Field and Biomolecular Detection
Pu, X., ZhiJun, S., Yu, Z., Li, H., Wei, X., Yang, T., Liu, Q., Chai, G., Liang, X., & Gao, D. (2026) · Nano-Micro Letters · doi:10.1007/s40820-026-02317-2 · Cited by 1
“Born from the need to detect weak magnetic fields, Orthogonal Fluxgates (OFGs) are, in principle, an ideal compromise, characterized by high sensitivity, superior noise performance, and outstanding linearity [20–23].”
Low frequency noise investigation of pT-level magnetic sensors by cross-spectral method
Janošek, M., Novotny, D., Dressler, M., & Saunderson, E. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639875 · Cited by 1
“A future measurement with the 1-pT fluxgate [19] as a third instrument will bring us more confidence in the potential of the presented method and reliability of the established SQUID noise.”
MethodSelf-citationSchledewitz, T., & Rueter, D. (2024) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2024.3387345 · Cited by 1
“Although this sensitivity limit is inferior to recently shown techniques [24], it is preliminary sufficient herein: the herein actually predominant “noise” in practical measurements results from external EMI and mechanical/acoustic disturbances.”
MethodResultDesign and Simulation Implementation of an Improved Dual Fluxgate Sensor
Fang, Q., Lin, R., Zhu, X., & Shen, S. (2024) · International Conference on Advanced Computer Theory and Engineering · doi:10.1109/icacte62428.2024.10871404 · Cited by 1
Developing Gradiometer to Reduce the Low Frequency Noise of Magnetic Sensor with Amorphous Wire
He, D. (2021) · Journal of Electrical and Electronic Engineering · doi:10.11648/j.jeee.20210902.11 · Cited by 1
“Although these sensors are not so sensitive compared with superconducting quantum interference device (SQUID) and on optical pumping magnetic sensor [6, 7], due to the small sizes and the easy operation, room temperature high-sensitivity magnetic sensors have found applications of bio-magnetic sensing [8], communicati…”
BackgroundEffect of Excitation Parameters on Fluxgate Sensing Element Response
Elkattan, M., Mostafa, H., & Khalil, A. H. (2021) · IEEE Regional Symposium on Micro and Nanoelectronics · doi:10.1109/rsm52397.2021.9511603 · Cited by 1
Study of the Impact of Design Factors on Micro-Fluxgate Sensing Element
Elkattan, M., Mostafa, H., & Khalil, A. H. (2021) · IEEE International Conference on Sensors and Nanotechnology (SENNANO) · doi:10.1109/sennano51750.2021.9642679
Responsivity of Fluxgate Sensing Element Under Different Excitation Conditions
Elkattan, M., Mostafa, H., & Khalil, A. H. (2021) · International Conference on Intelligent and Advanced Systems · doi:10.1109/icias49414.2021.9642605
Сокол-Кутыловский, О. Л. (2022) · Technical Physics Letters · doi:10.1134/s1063785022080041
Modeling RTD ferroprobe converter in Comsol environment
Kolomeitsev, A. A., Baranov, P. F., Il’yaschenko, D. P., & Sapozhkov, S. B. (2022) · AIP conference proceedings · doi:10.1063/5.0106764
Two Tone Excitation for Fundamental Mode Orthogonal Fluxgate Gradiometer
Dressler, M., Gonzales, M. B., & Janošek, M. (2025) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors59705.2025.11331113
“The low noise and better spatial resolution of magnetic mi-crowire based magnetometers motivated the research of their use for magnetocardiography [7], [8], [9].”
Self-citationPu, Z., Liu, Z., Lei, C., Du, J., Dai, Y., & Fang, D. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118507
Pu, X., ZhiJun, S., Liu, F., Huaidong, L. I., Yu, Z., Liu, Z. Y., Xia, B., Chai, J., Jiang, C., Chai, G., et al. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71365
2D-Based Sub-Nanotesla Sensitivity Metasurface Solid-State Optical Magnetometer
Sharif, S., & Banad, Y. M. (2026) · IEEE Research and Applications of Photonics in Defense Conference (RAPID) · doi:10.1109/rapid65318.2026.11719975
“Fluxgate sensors offer vector capability at the cost of reduced sensitivity [9].”
Metadata
- Authors
- Janosek, M., Butta, M., Dressler, M., Saunderson, E., Novotny, D., & Fourie, C.
- Affiliations
- Czech Technical University in Prague (CZ)
- South African National Space Agency (ZA)
- Stellenbosch University (ZA)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2020-05
- Volume
- 69
- Issue
- 5
- Pages
- 2552-2560
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2981880989
- Cited by
- 70
- References
- 28
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 14 · 2023: 6 · 2022: 17 · 2021: 16 · 2020: 3
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Czech Technical University Digital Library (Czech Technical University in Prague) (acceptedVersion, other-oa)
- Funders
- Grantová Agentura České Republiky (16-10591Y (Magnetic Gradiometer Based on Fundamental Mode Orthogonal Fluxgate))
- Czech Technical University in Prague through the Mobility Grant, International Mobility of Researches in CTU (CZ.02.2.69/0.0/0.0/16_027/0008465)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- fluxgate magnetometer, geomagnetic observations, magnetocardiography, magnetotellurics, offset drift, white noise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.