MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A point-contact (SQUID) magnetometer was used inside a shielded room to record the magnetic field of the human heart, without noise-averaging. The resulting magnetocardiograms, with the peak signal at about 3 × 10−7 G had a noise level of about 1 × 10−9 G (rms, per root cycle). They approach good medical electrocardiograms in clarity, and are an order-of-magnitude improvement in sensitivity over previous magnetic detectors of the heart. These results suggest new medical uses for this magnetometer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“finally providing an experimental setup and a magnetic signal-to-noise ratio (SNR) suitable for recording cardiac and even brain biomagnetic signals (13, 14).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [13]
Citations
Cites
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Self-citationDetection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Quantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Self-citationMagnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
Self-citationTheory of Magnetic Detection of the Heart's Electrical Activity
Baule, G., & McFee, R. (1965) · Journal of Applied Physics · doi:10.1063/1.1714404 · Cited by 112
Measurements and a Simplified Interpretation of Magnetocardiograms from Humans
COHEN, D., & CHANDLER, L. (1969) · Circulation · doi:10.1161/01.cir.39.3.395 · Cited by 50
Self-citation
Cited by
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Self-citationSuperconducting quantum interference device instruments and applications
Fagaly, R. L. (2006) · Review of Scientific Instruments · doi:10.1063/1.2354545 · Cited by 594
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Wikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
Metadata
- Authors
- Cohen, D., Edelsack, E. A., & Zimmerman, J. E.
- Affiliations
- Massachusetts Institute of Technology (US)
- Office of Naval Research (US)
- Philco-Ford (United States) (US)
- ORCID
- Cohen, David
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1970-04-01
- Volume
- 16
- Issue
- 7
- Pages
- 278-280
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2055429396
- Cited by
- 361
- References
- 6
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 9 · 2021: 5 · 2020: 9 · 2019: 8 · 2018: 8 · 2017: 5 · 2016: 2 · 2015: 4 · 2014: 8 · 2013: 13 · 2012: 7
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, SQUID magnetometer, superconducting magnetometer, cardiac magnetic field, magnetic shielding, noise sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER. https://app.cochat.ai/papers/10.1063/1.1653195
- The paper
- Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970). MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER. Applied Physics Letters. https://doi.org/10.1063/1.1653195
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.