A Multitier Deep Learning Model for Arrhythmia Detection
Open accessAbstract
An electrocardiograph (ECG) is employed as a primary tool for diagnosing cardiovascular diseases (CVDs). ECG signals provide a framework to probe the underlying properties and enhance the initial diagnosis obtained via traditional tools and patient-doctor dialogs. Notwithstanding its proven utility, deciphering large data sets to determine appropriate information remains a challenge in ECG-based CVD diagnosis and treatment. Our study presents a deep neural network (DNN) strategy to ameliorate the aforementioned difficulties. Our strategy consists of a learning stage where classification accuracy is improved via a robust feature extraction protocol. This is followed by using a genetic algorithm (GA) process to aggregate the best combination of feature extraction and classification. Comparison of the performance recorded for the proposed technique alongside state-of-the-art methods reported the area shows an increase of 0.94 and 0.953 in terms of average accuracy and F1 score, respectively. The outcomes suggest that the proposed model could serve as an analytic module to alert users and/or medical experts when anomalies are detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Classification of Heart Diseases Based On ECG Signals Using Long Short-Term Memory
Liu, M., & Kim, Y. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512761 · Cited by 83
Cited by
Ansari, Y., Mourad, O., Qaraqe, K., & Serpedin, E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1246746 · Cited by 291
Matthiesen, S., Diederichsen, S. Z., Hansen, M. K. H., Villumsen, C., Lassen, M. C. H., Jacobsen, P. K., Risum, N., Winkel, B. G., Philbert, B. T., Svendsen, J. H., et al. (2021) · JMIR Human Factors · doi:10.2196/26964 · Cited by 45
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Hammad, M., Iliyasu, A. M., Subasi, A., Ho, E. S. L., & El-Latif, A. A. A.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-9
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3093086118
- Cited by
- 247
- References
- 3
- FWCI
- 20.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Multitier Deep Learning Model for Arrhythmia Detection. https://app.cochat.ai/papers/10.1109/tim.2020.3033072
- The paper
- Hammad, M., Iliyasu, A. M., Subasi, A., Ho, E. S. L., & El-Latif, A. A. A. (2021). A Multitier Deep Learning Model for Arrhythmia Detection. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2020.3033072
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.