DeprNet: A Deep Convolution Neural Network Framework for Detecting Depression Using EEG
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Depression is a common reason for an increase in suicide cases worldwide. Thus, to mitigate the effects of depression, accurate diagnosis and treatment are needed. An electroencephalogram (EEG) is an instrument used to measure and record the brain's electrical activities. It can be utilized to produce the exact report on the level of depression. Previous studies proved the feasibility of the usage of EEG data and deep learning (DL) models for diagnosing mental illness. Therefore, this study proposes a DL-based convolutional neural network (CNN) called DeprNet for classifying the EEG data of depressed and normal subjects. Here, the Patient Health Questionnaire 9 score is used for quantifying the level of depression. The performance of DeprNet in two experiments, namely, the recordwise split and the subjectwise split, is presented in this study. The results attained by DeprNet have an accuracy of 0.9937, and the area under the receiver operating characteristic curve (AUC) of 0.999 is achieved when recordwise split data are considered. On the other hand, an accuracy of 0.914 and the AUC of 0.956 are obtained, while subjectwise split data are employed. These results suggest that CNN trained on recordwise split data gets overtrained on EEG data with a small number of subjects. The performance of DeprNet is remarkable compared with the other eight baseline models. Furthermore, on visualizing the last CNN layer, it is found that the values of right electrodes are prominent for depressed subjects, whereas, for normal subjects, the values of left electrodes are prominent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
The use of the area under the ROC curve in the evaluation of machine learning algorithms
Bradley, A. P. (1997) · Pattern Recognition · doi:10.1016/s0031-3203(96)00142-2 · Cited by 7,217 · cited 1×
“The AUC is considered in this study to visualize the performance of a model graphically [45].”
MethodShin, H.-C., Roth, H. R., Gao, M., Lu, L., Xu, Z., Nogues, I., Yao, J., Mollura, D., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528162 · Cited by 5,759
Deep learning with convolutional neural networks for EEG decoding and visualization
Schirrmeister, R. T., Springenberg, J. T., Fiederer, L. D. J., Glasstetter, M., Eggensperger, K., Tangermann, M., Hutter, F., Burgard, W., & Ball, T. (2017) · Human Brain Mapping · doi:10.1002/hbm.23730 · Cited by 3,751
Empirical Evaluation of Rectified Activations in Convolutional Network
Xu, B., Wang, N., Chen, T., & Li, M. (2015) · arXiv · doi:10.48550/arxiv.1505.00853 · Cited by 2,264 · cited 1×
“The last fully connected layer uses softmax activation function, while all other layers use leaky rectified linear unit (LeakyReLU) activation function [32], [33].”
MethodDeep learning for electroencephalogram (EEG) classification tasks: a review
Craik, A., He, Y., & Contreras-Vidal, J. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0ab5 · Cited by 1,758 · cited 2×
“However, Craik et al. [4] revealed that 37% of the previous studies did not preprocess the EEG data, 49% removed artifacts manually, and 14% used automatic artifact removal techniques.”
MethodCerebral location of international 10–20 system electrode placement
Homan, R. W., Herman, J., & Purdy, P. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90206-9 · Cited by 1,407
Particular object retrieval with integral max-pooling of CNN activations
Tolias, G., Sicre, R., & Jégou, H. (2015) · arXiv · doi:10.48550/arxiv.1511.05879 · Cited by 744 · cited 1×
“3) Pooling Layers: In DeprNet, max-pooling layers are exploited for down-sampling the data [36].”
Background
Cited by
Chaddad, A., Wu, Y., Kateb, R., & Bouridane, A. (2023) · Sensors · doi:10.3390/s23146434 · Cited by 305
Wang, L., Wang, C., Li, C., Murai, T., Bai, Y., Song, Z., Zhang, S., Zhang, Q., Huang, Y., Bi, X., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01933-3 · Cited by 33
Metadata
- Authors
- Seal, A., Bajpai, R., Agnihotri, J., Yazidi, A., Herrera-Viedma, E., & Krejcar, O.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-13
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3126085817
- Cited by
- 265
- References
- 45
- FWCI
- 18.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.