Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 882

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

DS-TransUNet: Dual Swin Transformer U-Net for Medical Image Segmentation

Open access
Lin, Ailiang, Chen, Bingzhi, Xu, Jiayu, Zhang, Zheng, Lu, Guangming, Zhang, David·2022·IEEE Transactions on Instrumentation and Measurement

Abstract

Automatic medical image segmentation has made great progress owing to the powerful deep representation learning. Inspired by the success of self-attention mechanism in Transformer, considerable efforts are devoted to designing the robust variants of encoder-decoder architecture with Transformer. However, the patch division used in the existing Transformer-based models usually ignores the pixel-level intrinsic structural features inside each patch. In this paper, we propose a novel deep medical image segmentation framework called Dual Swin Transformer U-Net (DS-TransUNet), which aims to incorporate the hierarchical Swin Transformer into both encoder and decoder of the standard U-shaped architecture. Our DS-TransUNet benefits from the self-attention computation in Swin Transformer and the designed dual-scale encoding, which can effectively model the non-local dependencies and multi-scale contexts for enhancing the semantic segmentation quality of varying medical images. Unlike many prior Transformer-based solutions, the proposed DS-TransUNet adopts a well-established dual-scale encoding mechanism that utilizes dual-scale encoders based on Swin Transformer to extract the coarse and fine-grained feature representations of different semantic scales. Meanwhile, a well-designed Transformer Interactive Fusion (TIF) module is proposed to effectively perform the multi-scale information fusion through the self-attention mechanism. Furthermore, we introduce the Swin Transformer block into decoder to further explore the long-range contextual information during the up-sampling process. Extensive experiments across four typical tasks for medical image segmentation demonstrate the effectiveness of DS-TransUNet, and our approach significantly outperforms the state-of-the-art methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2022.3178991

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 882

Metadata

Authors
Lin, A., Chen, B., Xu, J., Zhang, Z., Lu, G., & Zhang, D.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2022
Volume
71
Pages
1-15
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W3168491317
Cited by
882
References
22
FWCI
64.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: DS-TransUNet: Dual Swin Transformer U-Net for Medical Image Segmentation. https://app.cochat.ai/papers/10.1109/tim.2022.3178991
The paper
Lin, A., Chen, B., Xu, J., Zhang, Z., Lu, G., & Zhang, D. (2022). DS-TransUNet: Dual Swin Transformer U-Net for Medical Image Segmentation. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2022.3178991

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.