The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
CNN-Based Transformer Model for Fault Detection in Power System Networks
Abstract
Fault detection and localization in electrical power lines has long been a crucial challenge for electrical engineers as it allows the detected fault to be isolated and recovered promptly. These faults, if neglected, can rupture the normal operation of the network and drastically damage the power lines and the equipment attached to it. The wastage of power and money due to these faults can be harmful to the economy of an industry or even a country. Therefore, efficient fault detection mechanisms have become crucial for the well-being of this power-hungry world. This research presents an end-to-end deep learning strategy to detect and localize symmetrical and unsymmetrical faults as well as high-impedance faults (HIFs) in a distribution system. This research proposes a novel deep convolutional neural network (CNN) transformer model to automatically detect the type and phase of the fault as well as the location of the fault. The proposed model utilizes 1-D deep CNNs for feature extraction and transformer encoder for sequence learning. The transformer encoder utilizes an attention mechanism to integrate the sequence embeddings and focus on significant time steps to learn long-term dependence to extract the context of the temporal current data. The different faults were simulated in MATLAB Simulink using IEEE 14-bus distribution system. The proposed models were found to produce better performance on the test database when evaluated using F1-Score, Matthews correlation coefficient (MCC), and accuracy. The models also produced better predictions on HIFs compared to conventional fault-detection techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
Rethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
Xception: Deep Learning with Depthwise Separable Convolutions
Chollet, F. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.195 · Cited by 20,380
EfficientNet: Rethinking Model Scaling for Convolutional Neural Networks
Tan, M., & Le, Q. V. (2019) · arXiv · doi:10.48550/arxiv.1905.11946 · Cited by 17,072
Aggregated Residual Transformations for Deep Neural Networks
Xie, S., Girshick, R., Dollar, P., Tu, Z., & He, K. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.634 · Cited by 12,465
Inception-v4, Inception-ResNet and the Impact of Residual Connections on Learning
Szegedy, C., Ioffe, S., Vanhoucke, V., & Alemi, A. (2017) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v31i1.11231 · Cited by 4,636
Transformers in Vision: A Survey
Khan, S., Naseer, M., Hayat, M., Zamir, S. W., Khan, F. S., & Shah, M. (2022) · ACM Computing Surveys · doi:10.1145/3505244 · Cited by 3,595
Transformers in Vision: A Survey
Khan, S., Naseer, M., Hayat, M., Zamir, S. W., Khan, F. S., & Shah, M. (2021) · arXiv · doi:10.48550/arxiv.2101.01169 · Cited by 3,594
Transformer-XL: Attentive language models beyond a fixed-length context
Dai, Z., Yang, Z., Yang, Y., Carbonell, J., Le, Q., & Salakhutdinov, R. (2019) · Proceedings of the 57th Annual Meeting of the Association for Computational Linguistics · doi:10.18653/v1/p19-1285 · Cited by 3,169
Cited by
Alam, M. M., Hossain, M. J., Habib, M. A., Arafat, M. Y., & Hannan, M. A. (2025) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2024.115251 · Cited by 76
Metadata
- Authors
- Thomas, J. B., Chaudhari, S. G., K. V., S., & Verma, N. K.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2023
- Volume
- 72
- Pages
- 1-10
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W4320001385
- Cited by
- 275
- References
- 33
- FWCI
- 29.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CNN-Based Transformer Model for Fault Detection in Power System Networks. https://app.cochat.ai/papers/10.1109/tim.2023.3238059
- The paper
- Thomas, J. B., Chaudhari, S. G., K. V., S., & Verma, N. K. (2023). CNN-Based Transformer Model for Fault Detection in Power System Networks. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2023.3238059
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.