Cited by 14Reliability and Maintenance OptimizationMachine Fault Diagnosis TechniquesFault Detection and Control Systems

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A New Health Index for RUL Estimation of MEMS Sensors Using Dimensionality Reduction and Artificial Neural Networks

Open access
Carratù, Marco, Gallo, Vincenzo, Dello Iacono, Salvatore, Sommella, Paolo, Ciani, Lorenzo, Patrizi, Gabriele·2025·IEEE Transactions on Instrumentation and Measurement

Abstract

The accurate estimation of the remaining useful life (RUL) of micro-electromechanical systems (MEMS) sensors is crucial for enabling effective condition-based maintenance (CBM) and improving system reliability. This is of vital importance in planning machinery replacements before their actual fault, reducing downtime and thus greatly optimizing costs. However, unlike industrial components (such as bearings, rotating machinery, or power devices), current prognostic strategies for MEMS sensors are limited due to the lack of suitable health indexes (HIs) capable of describing the degradation path of the sensor’s metrological performances. To address this gap, this article proposes a novel HI for MEMS accelerometers based on static accelerometer outputs by combining time-domain and frequency-domain features using a dimensionality reduction technique. By applying dimensionality reduction, the method captures the essential characteristics of sensor degradation, which are then used to train a deep learning-based model for predicting the RUL sufficiently in advance to allow for appropriate maintenance. This article aims to fill an important gap by providing an innovative solution for MEMS sensor prognostics, with broad implications for industrial sectors reliant on precision sensing technologies. The performance of the proposed health indicator is validated through experimental data, demonstrating its ability to enhance the accuracy of MEMS sensor prognostics. Using data from the proposed accelerated life test and the Arrhenius degradation model, the RUL prediction based on the proposed health indicator has been performed at various operating temperatures, including typical conditions of industrial environments with high thermal stress.

Overview

Integrity signals

Registry

Crossref · 10.1109/tim.2024.3502814

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 1 references

Research works printed but not linked: 53

  1. 10.1109/tim.2019.2947126 · DOI
  2. 10.1109/tim.2021.3126390 · DOI
  3. 10.1109/tii.2019.2891261 · DOI
  4. 10.1109/tim.2020.2985614 · DOI
  5. 10.1007/978-3-030-14973-4_17 · DOI
  6. 10.1016/j.measurement.2022.112351 · DOI
  7. 10.1109/tim.2023.3318684 · DOI
  8. 10.1109/tim.2020.2968160 · DOI
  9. 10.1109/TR.2010.2085572 · DOI
  10. 10.1016/j.cie.2012.02.002 · DOI
  11. 10.1016/j.cie.2020.106889 · DOI
  12. 10.1109/TIM.2021.3111009 · DOI
  13. 10.1109/MetroAutomotive50197.2021.9502884 · DOI
  14. 10.1016/j.jmsy.2021.12.013 · DOI
  15. 2024, Maintenance Programs
  16. 10.3390/s22176321 · DOI
  17. 10.1109/tim.2012.2212508 · DOI
  18. 10.1109/TMECH.2021.3053173 · DOI
  19. 10.1016/j.procir.2016.11.182 · DOI
  20. 10.1109/TAES.1978.308607 · DOI
  21. 10.1109/ASE.1999.802168 · DOI
  22. 10.1038/micronano.2015.5 · DOI
  23. 10.1007/s13198-013-0195-0 · DOI
  24. 10.1007/s00170-009-2482-0 · DOI
  25. 10.1016/0143-8174(82)90036-1 · DOI
  26. 10.3390/app132413041 · DOI
  27. 10.1109/23.467727 · DOI
  28. 10.1006/mssp.2000.1309 · DOI
  29. 10.1080/07408170590929018 · DOI
  30. 10.1016/j.csda.2007.07.003 · DOI
  31. 10.1080/07408170600847168 · DOI
  32. 10.1093/imaman/13.1.3 · DOI
  33. 10.1109/aero.2004.1368175 · DOI
  34. 10.3390/app9030613 · DOI
  35. 10.36001/phme.2014.v2i1.1527 · DOI
  36. 10.1109/TIE.2016.2515054 · DOI
  37. 10.3390/machines5040021 · DOI
  38. 10.1016/j.ymssp.2004.09.001 · DOI
  39. 10.38094/jastt1224 · DOI
  40. 10.1109/ACCESS.2020.2980942 · DOI
  41. 10.30880/jscdm.2021.02.01.003 · DOI
  42. Coble, Identifying optimal prognostic parameters from data: A genetic algorithms approach, 1, 1
  43. 10.1109/PLANS.2018.8373425 · DOI
  44. 10.1016/j.measurement.2011.05.015 · DOI
  45. 10.21014/tc10-2022.010 · DOI
  46. 10.3390/machines10090729 · DOI
  47. 10.1016/j.isatra.2022.04.042 · DOI
  48. 10.1007/s12206-014-1222-z · DOI
  49. 10.36001/ijphm.2010.v1i1.1336 · DOI
  50. 10.1109/TASE.2006.876609 · DOI
  51. 2009, Evaluation of Measurement Data—An Introduction to the `Guide to the Expression of Uncertainty in Measurement’ and Related Documents. Joint Committee for Guides in Metrology
  52. Crowe, 2001, Design for Reliability
  53. 10.1021/ed061p494 · DOI

Cited by

Sorted by citations

See all 14

Metadata

Authors
Carratù, M., Gallo, V., Dello Iacono, S., Sommella, P., Ciani, L., & Patrizi, G.
Affiliations
  • University of Salerno (IT)
  • Department of Information Engineering, University of Brescia, Brescia, Italy
  • University of Florence (IT)
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2025
Volume
74
Pages
1-12
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W4404563861
Cited by
14
References
1
Citations by year
2026: 11 · 2025: 3
FWCI
3.64
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Instrumentation and Measurement (publishedVersion, cc-by)
  • Florence Research (University of Florence) (submittedVersion, cc-by)
  • Institutional Research Information System (Università degli Studi di Brescia) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Reliability and Maintenance Optimization
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
Keywords
remaining useful life prediction, MEMS accelerometer, health indicators, condition-based maintenance, sensor degradation, dimensionality reduction, time and frequency domain features, accelerated life testing, temperature effects, prognostics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review