Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index; 7 of the 22 sources its claims cite were checked for support.

Signal Estimation and Uncertainties Extraction in Terahertz Time-Domain Spectroscopy

Open access
Denakpo, Elsa, Hannotte, Théo, Osseiran, Noureddin, Orieux, François, Peretti, Romain · 2025 · IEEE Transactions on Instrumentation and Measurement

Abstract

Terahertz time-domain spectroscopy (THz-TDS) systems have emerged as mature technologies with significant potential across various research fields and industries. However, the lack of standardized signal and noise estimation and reduction methods hinders its full potential. This article introduces a methodology to significantly reduce noise in THz-TDS time traces, providing a reliable and less-biased signal estimation. The method results in an improved signal-to-noise ratio (SNR), enabling the utilization of the full dynamic range of such setups. Additionally, we investigate the estimation of the covariance matrix to quantify the uncertainties associated with the signal estimator. This matrix is essential for extracting accurate material parameters by normalizing the error function in the fitting process. Our approach addresses practical scenarios where the number of repeated measurements is limited compared to the number of sampling points on the time axis. We envision this work as the initial step toward standardizing THz-TDS data processing. We believe that it will foster collaboration between the THz and signal processing communities, leading to the development of more sophisticated methods to tackle challenges posed by novel setups, such as those dedicated to dual-comb spectroscopy, which demands significant optimization of signal-to-noise performance.

Overview

CoChat Summary

TL;DR

The paper proposes signal-estimation and noise-covariance methods for THz time-domain spectroscopy, correcting delay-line drift, laser amplitude fluctuations, and periodic sampling errors to reduce bias and improve SNR. It also evaluates covariance and precision matrix estimators for uncertainty propagation in material-parameter fitting, implementing the approach in the open-source Correct@TDS software.

Key findings

  • Correcting delay-line drift increased SNR from 28 dB to 55 dB for 1,000 time traces, an approximately 27 dB gain; adding laser amplitude correction further increased SNR to 62 dB, an approximately 7 dB gain.
  • The raw average is biased by delay drift: attenuation exceeded 20% at 3 THz and worsened for 50,000 traces, while the corrected average matched the predicted attenuation model up to 4 THz.
  • Periodic sampling errors produced artifacts beginning around 7.5 THz; the proposed correction reduced them using a Tukey window.
  • For covariance estimation with n ≤ p, Graphical Lasso performed better than Ledoit-Wolf and Oracle Approximating Shrinkage, giving good estimation with as few as 100 time traces; corrections reduced covariance values by three orders of magnitude, and precision-matrix partial correlations increased by one order of magnitude after correction. The conclusion reports over 30 dB SNR enhancement at 1 THz for 1,000 accumulated traces.

Methods

  • Experiments used a MenloSystems TeraSmart THz-TDS setup with a 100 MHz repetition-rate laser, an 850 ps delay line, 33 fs time step, and typical bandwidth around 4 THz. Tests included dark noise, THz-dark perturbation, and 100,000 dry-nitrogen time traces over 100 ps.
  • The signal estimator aligns traces to a reference via Fourier shift, corrects delay-line speed variation using a first-order Taylor expansion, corrects laser amplitude fluctuations, and reduces periodic sampling errors; these are implemented in Correct@TDS.
  • Covariance and precision matrices were estimated from corrected repeated measurements, comparing empirical covariance, Ledoit-Wolf shrinkage, Oracle Approximating Shrinkage, and Graphical Lasso from scikit-learn. Target matrices were computed from 100,000 traces with p = 3000 sampling points, and performance was assessed by normalized Frobenius distances and matrix norms.

Limitations

  • The paper states there is no standard protocol for THz-TDS data acquisition/processing or uncertainty extraction, and that covariance inversion requires more repeated measurements than time-sampling points, which is often impractical: a 400 ps trace has about 12,500 points, and 12,501 traces take about 2 hours.
  • The paper notes that lasso-penalized methods can be inconsistent on some graph structures, precision-matrix estimation has no optimal solution, and the covariance-estimation scope was limited to reference data without samples.
  • Evident from the text: tests used one specific commercial setup and selected experimental conditions; delay-line speed correction was negligible for a single-peak reference but important for echoes outside the paper’s scope; target matrices were assumed true based on 100,000 traces.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1109/tim.2025.3554287

Cites

77 of 77 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

4 Valid · 5 Not valid · 7 Not checked · 72 Own results and interpretations

28 more claims

Create a free account to see all 88 claims and to verify the 2 references still open.

See all claims — free account
  • Probably not a substantial claim. 21
  • It may state two separate claims as one. 37
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Citations

Cites

Show all 67 references

Research works printed but not linked: 2

  1. Denakpo, 2024, Software: Correct@tds
  2. Peretti, 2024, Full Acquisition of 100k & 50k Terahertz Time Domain Spectroscopy Reference Time Traces

Cited by

See all 6

Metadata

Authors
Denakpo, E., Hannotte, T., Osseiran, N., Orieux, F., & Peretti, R.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2025
Volume
74
Pages
1-13
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W4403241476
Cited by
6
References
67
Citations by year
2026: 5 · 2025: 1
FWCI
1.35
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Instrumentation and Measurement (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • HAL (submittedVersion, other-oa)
  • Figshare (submittedVersion, public-domain)
  • LillOA (Université de Lille (University Of Lille)) (submittedVersion, other-oa)
  • arXiv (Cornell University)
Funders
  • R?gion ?Hauts-de-France?
  • Diagnotera Start-AIRR project
  • DEUS MAROONER STIMulE project
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
Keywords
terahertz time-domain spectroscopy, noise reduction, signal estimation, signal-to-noise ratio, covariance matrix estimation, uncertainty quantification, parameter fitting, dual-comb spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Signal Estimation and Uncertainties Extraction in Terahertz Time-Domain Spectroscopy. https://app.cochat.ai/papers/10.1109/tim.2025.3554287
The paper
Denakpo, E., Hannotte, T., Osseiran, N., Orieux, F., & Peretti, R. (2025). Signal Estimation and Uncertainties Extraction in Terahertz Time-Domain Spectroscopy. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2025.3554287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.