The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Speckle reducing anisotropic diffusion
Abstract
This paper provides the derivation of speckle reducing anisotropic diffusion (SRAD), a diffusion method tailored to ultrasonic and radar imaging applications. SRAD is the edge-sensitive diffusion for speckled images, in the same way that conventional anisotropic diffusion is the edge-sensitive diffusion for images corrupted with additive noise. We first show that the Lee and Frost filters can be cast as partial differential equations, and then we derive SRAD by allowing edge-sensitive anisotropic diffusion within this context. Just as the Lee and Frost filters utilize the coefficient of variation in adaptive filtering, SRAD exploits the instantaneous coefficient of variation, which is shown to be a function of the local gradient magnitude and Laplacian operators. We validate the new algorithm using both synthetic and real linear scan ultrasonic imagery of the carotid artery. We also demonstrate the algorithm performance with real SAR data. The performance measures obtained by means of computer simulation of carotid artery images are compared with three existing speckle reduction schemes. In the presence of speckle noise, speckle reducing anisotropic diffusion excels over the traditional speckle removal filters and over the conventional anisotropic diffusion method in terms of mean preservation, variance reduction, and edge localization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Digital Image Processing: PIKS Inside
Pratt, W. K. (2002) · Wiley eBooks · doi:10.1002/0471221325 · Cited by 4,340
Digital Image Enhancement and Noise Filtering by Use of Local Statistics
Lee, J.-S. (1980) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1980.4766994 · Cited by 2,728
Digital Image Processing: PIKS Scientific Inside
Pratt, W. K. (2007) · Wiley eBooks · doi:10.1002/0470097434 · Cited by 2,616
A Model for Radar Images and Its Application to Adaptive Digital Filtering of Multiplicative Noise
Frost, V. S., Stiles, J. A., Shanmugan, K. S., & HOLTZMAN, J. C. (1982) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1982.4767223 · Cited by 1,995
Structure detection and statistical adaptive speckle filtering in SAR images
LOPES, A., NEZRY, E., TOUZI, R., & LAUR, H. (1993) · International Journal of Remote Sensing · doi:10.1080/01431169308953999 · Cited by 584
Segmentation of intravascular ultrasound images: a knowledge-based approach
Sonka, M., Zhang, X., Siebes, M., Bissing, M. S., Dejong, S. C., Collins, S. M., & McKay, C. R. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.476113 · Cited by 235
Ultrasonic B-scanning: a computer simulation
Bamber, J. C., & Dickinson, R. J. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/3/006 · Cited by 223
Refined Filtering of Image Noise Using Local Statistics
Lee, J.-S. (1980) · doi:10.21236/ada080530 · Cited by 114
An adaptive nonlinear diffusion algorithm for filtering medical images
Jin, J. S., Wang, Y., & Hiller, J. B. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.897062 · Cited by 66
Acton, S. T. (2000) · IEEE Transactions on Signal Processing · doi:10.1109/78.839984 · Cited by 25
Self-citation
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Automated breast ultrasound lesions detection using convolutional neural networks
Yap, M. H., Pons, G., Martí, J., Ganau, S., Sentís, M., Zwiggelaar, R., Davison, A. K., & Martí, R. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2731873 · Cited by 1,086
Automated breast cancer detection and classification using ultrasound images: A survey
Cheng, H. D., Shan, J., Ju, W., Guo, Y., & Zhang, L. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2009.05.012 · Cited by 728
A Tutorial on Speckle Reduction in Synthetic Aperture Radar Images
Argenti, F., Lapini, A., Bianchi, T., & Alparone, L. (2013) · IEEE Geoscience and Remote Sensing Magazine · doi:10.1109/mgrs.2013.2277512 · Cited by 559
Active Contour External Force Using Vector Field Convolution for Image Segmentation
Li, B., & Acton, S. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.899601 · Cited by 393
Self-citation
Metadata
- Authors
- Yu, Y., & Acton, S. T.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2002-11
- Volume
- 11
- Issue
- 11
- Pages
- 1260-1270
- ISSN
- 1057-7149 (ISSN-L)
- OpenAlex
- W2130094715
- Cited by
- 1,850
- References
- 12
- FWCI
- 17.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.