The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Noise removal using fourth-order partial differential equation with applications to medical magnetic resonance images in space and time
Abstract
In this paper, we introduce a new method for image smoothing based on a fourth-order PDE model. The method is tested on a broad range of real medical magnetic resonance images, both in space and time, as well as on nonmedical synthesized test images. Our algorithm demonstrates good noise suppression without destruction of important anatomical or functional detail, even at poor signal-to-noise ratio. We have also compared our method with related PDE models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Image Selective Smoothing and Edge Detection by Nonlinear Diffusion. II
Alvarez, L., Lions, P.-L., & Morel, J.-M. (1992) · SIAM Journal on Numerical Analysis · doi:10.1137/0729052 · Cited by 2,208
Image recovery via total variation minimization and related problems
Chambolle, A., & Lions, P.-L. (1997) · Numerische Mathematik · doi:10.1007/s002110050258 · Cited by 1,569
Image Selective Smoothing and Edge Detection by Nonlinear Diffusion
Catté, F., Lions, P.-L., Morel, J.-M., & Coll, T. (1992) · SIAM Journal on Numerical Analysis · doi:10.1137/0729012 · Cited by 1,468
Black, M. J., Sapiro, G., Marimont, D. H., & Heeger, D. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661192 · Cited by 1,295
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
A Nonlinear Primal-Dual Method for Total Variation-Based Image Restoration
Chan, T. F., Golub, G. H., & Mulet, P. (1999) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827596299767 · Cited by 840
Fourth-order partial differential equations for noise removal
You, Y.-L., & Kaveh, M. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.869184 · Cited by 826
High-Order Total Variation-Based Image Restoration
Chan, T., Marquina, A., & Mulet, P. (2000) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827598344169 · Cited by 776
Wavelet-based Rician noise removal for magnetic resonance imaging
Nowak, R. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.791966 · Cited by 620
Estimation of the Noise in Magnitude MR Images
Sijbers, J., den Dekker, A. J., Van Audekerke, J., Verhoye, M., & Van Dyck, D. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00199-9 · Cited by 277
An introduction to NMR imaging: From the Bloch equation to the imaging equation
Hinshaw, W. S., & Lent, A. H. (1983) · Proceedings of the IEEE · doi:10.1109/proc.1983.12592 · Cited by 213
Geometric surface processing via normal maps
Taşdizen, T., Whitaker, R., Burchard, P., & Osher, S. (2003) · ACM Transactions on Graphics · doi:10.1145/944020.944024 · Cited by 141
Signal‐to‐noise efficiency in magnetic resonance imaging
Parker, D. L., & Gullberg, G. T. (1990) · Medical Physics · doi:10.1118/1.596503 · Cited by 110
$H^1$ Solutions of a class of fourth order nonlinear equations for image processing
Greer, J. B., & Bertozzi, A. L. (2004) · Discrete and Continuous Dynamical Systems · doi:10.3934/dcds.2004.10.349 · Cited by 52
Cited by
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Self-citationA New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975
Wu, C., & Tai, X.-C. (2010) · SIAM Journal on Imaging Sciences · doi:10.1137/090767558 · Cited by 615
Self-citationImage Decomposition and Restoration Using Total Variation Minimization and the H1
Osher, S., Solé, A., & Vese, L. (2003) · Multiscale Modeling & Simulation · doi:10.1137/s1540345902416247 · Cited by 613
Image denoising review: From classical to state-of-the-art approaches
Goyal, B., Dogra, A., Agrawal, S., Sohi, B. S., & Sharma, A. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.09.003 · Cited by 463
Metadata
- Authors
- Lysaker, M., Lundervold, A., & Tai, X.-C.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2003-12
- Volume
- 12
- Issue
- 12
- Pages
- 1579-1590
- ISSN
- 1057-7149 (ISSN-L)
- OpenAlex
- W2135036909
- Cited by
- 911
- References
- 17
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.