The effects of a visual fidelity criterion of the encoding of images
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Shannon's rate-distortion function provides a potentially useful lower bound against which to compare the rate-versus-distortion performance of practical encoding-transmission systems. However, this bound is not applicable unless one can arrive at a numerically-valued measure of distortion which is in reasonable correspondence with the subjective evaluation of the observer or interpreter. We have attempted to investigate this choice of distortion measure for monochrome still images. This investigation has considered a class of distortion measures for which it is possible to simulate the optimum (in a rate-distortion sense) encoding. Such simulation was performed at a fixed rate for various measures in the class and the results compared subjectively by observers. For several choices of transmission rate and original images, one distortion measure was fairly consistently rated as yielding the most satisfactory appearing encoded images.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
Information Theory and Reliable Communication.
Lee, P. M., & Gallager, R. T. (1970) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344305 · Cited by 5,399
Information Theory and Reliable Communication
Bell, D. A. (1969) · Electronics and Power · doi:10.1049/ep.1969.0319 · Cited by 4,012
Application of fourier analysis to the visibility of gratings
Campbell, F. W., & Robson, J. G. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008574 · Cited by 3,019
Torgerson, W. S. (1958) · Medical Entomology and Zoology · Cited by 2,920
(1961) · Information and Control · doi:10.1016/s0019-9958(61)80064-8 · Cited by 2,875
LERNER, A. (1959) · American Journal of Psychiatry · doi:10.1176/ajp.116.2.190 · Cited by 1,002
The Psychophysics of Sensory Function
Stevens, S. S. (2012) · Sensory Communication · doi:10.7551/mitpress/9780262518420.003.0001 · Cited by 780
Orientational selectivity of the human visual system
Campbell, F. W., & Kulikowski, J. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008101 · Cited by 688
Research works printed but not linked: 5
- sakrison, 1970, Notes on Analog Communication
- van ness, 1965, The effects of wavelength and luminance on visual modulation transfer, Excerpta Medica— Int Congress, 183
- shannon, 1960, Coding theorems for a discrete source with a fidelity criterion, Information and Decision Processes, 93
- mannos, 1972, A class of fidelity criteria for the encoding of visual images
- gray, 0, Universal coding with a fidelity criterion, IEEE Trans Inform Theory
Cited by
Items 901–1,000 of 1,000
Variable‐rate transform coding that controls quality of image using human visual model
Harada, H. (1993) · Systems and Computers in Japan · doi:10.1002/scj.4690240710
Improved dot diffusion using optimized diffused weighting and class matrix
Guo, J.-M., & Liu, Y.-F. (2008) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2008.4517810
Qi, X., & Wang, J. (2013) · IEEE International Conference on Multimedia and Expo workshops · doi:10.1109/icmew.2013.6618262
HVS based visual quality assessment for digital cinema environment
Cai, D., & Fang, W. (2010) · IEEE International Conference on Network Infrastructure and Digital Content (IC-NIDC) · doi:10.1109/icnidc.2010.5657784
A HVS-driven image segmentation framework using a local segmentation performance measure
Peng, R., & Varshney, P. K. (2010) · IEEE Western New York Image and Signal Processing Workshop (WNYISPW) · doi:10.1109/wnyipw.2010.5649767
“In this paper, we choose the one discussed in [ 9 ]”
MethodPerformance evaluation of wavelet based on human visual system
Hai-ping, H., & Mo, Y. (2002) · Journal of Shanghai University (English Edition) · doi:10.1007/s11741-002-0037-9
Image Watermarking Based on Adaptive Models of Human Visual Perception
Khawne, A., Hamamoto, K., & Chitsobhuk, O. (2010) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.130.1644
TEMPLATE MATCHING COMO TÉCNICA COMPUTACIONAL APLICADA AO MONITORAMENTO DE ÁREAS SURPEVISIONADAS
Florentino, G. H., Valentim, R. A. D. M., Bezerra, H. U., de Araújo, B. G., Lacerda, J. M. T., & Clemente, A. (2011) · Holos · doi:10.15628/holos.2011.414
Quality Evaluation of Decimated Images Using Visual Difference Predictor
Matsuoka, R., Jinno, T., & Okuda, M. (2013) · IEICE Transactions on Fundamentals of Electronics Communications and Computer Sciences · doi:10.1587/transfun.e96.a.1824
Digital halftoning based on K-means clustering
He, Z., Zhang, Y., & Zhan, Z. (2012) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2012.6360766
“We will use the term contrast sensitivity here, since we have used this terminology throughout Mannos and Sakrison(5) proposed a model of the human contrast sensitivity function.”
MethodImage compression based on pyramid sub-band filtering
Kuo, C., Hsieh, C., Lu, P., & Chao, C.-P. (1995) · International Journal of Electronics · doi:10.1080/00207219508926176
The effect of chromatic background for luminance contrast-sensitivity function
Li, S., Liao, N., Dong, S., Liao, T., Hu, W., & Lin, K. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2014170
Image registration using the likelihood ratio
Voles, R. (1978) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1978.0160
Content-based and perceptual bit-allocation using matching pursuits
Vleeschouwer, C. D., & Macq, B. M. M. (2001) · Signal Processing Image Communication · doi:10.1016/s0923-5965(00)00039-4
“A contrast sensitivity function (CSF) has been proposed by Mannos and Sakrison [32].”
BackgroundResultSSIM based video coding using 2D- DWT
Raju, R., & Arun, P. (2014) · International Conference on Control, Instrumentation, Communication and Computational Technologies · doi:10.1109/iccicct.2014.6993096
Online 3D retrieval based on perceptual quality
Cheng, I., & Basu, A. (2004) · ACM SIGGRAPH Conference (SIGGRAPH) · doi:10.1145/1186194.1186214
The Use of a High Order Error Measure in Nonlinear Modulation
Papantoni-Kazakos, P. (1977) · IRE Transactions on Communications Systems · doi:10.1109/tcom.1977.1093928
Perceptual Intra Video Encoder for High-Quality High-Definition Content
Martínez-Rach, M., López-Granado, O., Piñol, P., & Malumbres, M. P. (2013) · DCC · doi:10.1109/dcc.2013.89
An explanation of the Einstein-Monroe picture from the view of spatial frequency
Xiao, S., & Chen, X. (2012) · International Conference on Image Analysis and Signal Processing · doi:10.1109/iasp.2012.6425044
“Contrast Sensitivity Function (CSF), which is shown in Figure 2, can indicate a human’s attribute of spatial frequency; all of the pictures in our brain are pictures filtered by people’s own eyes [3].”
BackgroundA new progressive coding scheme for halftone dithered images using bit-interleaving
Guo, J.-M., Pei, S., & Lee, H. (2006) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20072
“…level image and the corresponding halftone images in position ( i , j ), respectively; R is the support region of the human visual coeffi-cients and w m,n is the human visual coefficient at ( m , n ), which can be obtained by psychophysical experiments (Mannos and Sakrison, 1974; Anastassiou, 1988).”
TFT-LCD Mura Detection Algorithm Using Multi-point 2-D FFT
Jang, Y.-B., & Kim, H.-J. (2010) · Journal of the Korea Academia-Industrial cooperation Society · doi:10.5762/kais.2010.11.4.1278
COMPUTATIONAL VISUAL SENSITIVITY MODELS — A REVIEW
Lu, Z., & Chi, Z. (2004) · International Journal of Information Acquisition · doi:10.1142/s0219878904000331
Xiao, S., & Tian, Y. (2011) · International Conference on Image Analysis and Signal Processing · doi:10.1109/iasp.2011.6109118
Hamada, T., & Matsumoto, S. (1993) · Electronics and Communications in Japan (Part I Communications) · doi:10.1002/ecja.4410761106
The acceptance of information, its subjective cost and the measurement of distortion (Corresp.)
Wilson, R. (1982) · IEEE Transactions on Information Theory · doi:10.1109/tit.1982.1056576
HD-MAC HDTV distribution via an ATM broadband network
Hurk, J. J. V. D. (1990) · TU/e Research Portal
Source and Channel Coding for Audiovisual Communication Systems
Kim, M. Y. (2004) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Optimization of multirate filter banks within the framework of a human visual model
Lundblad, J. A. (1991) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.1991.176085
PECSI: A PRACTICAL PERCEPTUALLY-ENHANCED COMPRESSION FRAMEWORK FOR STILL IMAGES
Wong, A. K. C. (2009) · International Journal of Image and Graphics · doi:10.1142/s0219467809003551
Digital halftoning algorithm using visual-optimized binary patterns
Lee, H. J., Yoo, Y. J., & Park, H. W. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1996.559553
“X/96/$5.00 0 1996 IEEE A contrast sensitivity function (CSF) was developed to simulate the optimum encoding of still image by Mannos and Sakrison [5].”
MethodInfluentialMasked nearly-orthogonal wavelet-based image compression and its application to medical imaging
Sugavaneswaran, L., Swamy, M. N. S., & Wang, C. (2007) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2007.4488589
“In this paper, using the Mannos and Sakrison’s contrast sensitivity model [6] for the HVS, a peak-average contrast masker, is derived with the intent of enhancing the visual quality of the reconstructed image.”
BackgroundMethodPerceptual-Based Fusion of Infrared and Visual Images in Nonsubsampled Contourlet Transform
Fu, P. X., Sheng, S. Y., Wang, B., & Qiang, Z. Z. (2015) · International Conference on Intelligent Human-Machine Systems and Cybernetics · doi:10.1109/ihmsc.2015.78
“A lot of CSFs have been d literature [10-13].”
BackgroundRCBM: a rough content-based image quality assessment metric
Yu, Q., Dong, W., & Zhang, C. N. (2013) · International Journal of Granular Computing Rough Sets and Intelligent Systems · doi:10.1504/ijgcrsis.2013.054126
“To address the difficulty of the subjective image quality assessment, various objective image quality assessment techniques are employed to accurately and automatically provide quantitative measures that can predict perceived image quality without the subjective individual involved (Eckert and Bradley, 1998; Gao et al…”
MethodAn objective quality measure for still moncromatic DPCM-coded images
Karlsson, E., & Mersereau, R. M. (2005) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1983.1171945
Fast computation of perceptually optimal quantization matrices for MPEG-2 intra pictures
Chen, Y., & Challapali, K. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1998.999031
“Sakrison’s work on contrast sensitivity of the human vision system (HVS) [ 4 ], where the authors proposed the Modulation Transfer Function (MTF) to model the differing perception of noise by huinan eyes.”
BackgroundPerceptual image quality and telescope performance ranking
Lentz, J. K., Harvey, J. E., Marshall, K. H., Salg, J., & Houston, J. B. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.862833
Gifford, E., Hunt, B. R., & Marcellin, M. W. (2002) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1994.389483
QR-RLS algorithm for error diffusion of color images
Ünal, G., Yardımcı, Y., Arıkan, O., & Cetin, E. A. (2000) · Optical Engineering · doi:10.1117/1.1313749
A Quality Assessment of Watermarked Color Image Based on Vision Masking
Yang, H.-M. (2010) · International Journal of Information Technology and Computer Science · doi:10.5815/ijitcs.2010.02.07
Bouziane, M., Noumeir, R., & Gargour, C. S. (2002) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2001.933569
Multitoning using generalized projections and the DCT
Small, J. A., & Parker, K. J. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1994.413511
Sur une approche visuelle de protection inégale des images codées DCT
Poda, P., & Tamtaoui, A. (2007)
Embedded lowlight image quality measure
Pan, Y., & Wang, J. (2012) · IEEE International Conference on Computer Science and Automation Engineering · doi:10.1109/icsess.2012.6269463
Measures, Moments, And Perceptual Signal Processing
Moloney, C. R., Seetharaman, S., & Jernigan, M. E. (2005) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1988.754364
Multipurpose watermarking based on curvelet transform
Zhang, C., Cheng, L. L., Cheng, L. M., & Qiu, Z. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4542078
“From CSF, we could calculate the Just Noticeable Distance (JND) to be quantization steps and obtain good vision result.”
MethodInfluentialAnalysis of compressed depth and image streaming on unreliable networks
Zanuttigh, P., Zanella, A., & Cortelazzo, G. M. (2008) · IEEE Symposium on Computers and Communications (ISCC) · doi:10.1109/iscc.2008.4625772
“Different metrics, for example the frequency domain-based ones [7] or perceptual ones [4], have been proposed to overcome this issue and will be considered in future work.”
BackgroundKang, H. R. (1999) · Wiley eBooks · doi:10.1002/047134608x.w4104
Perceptual Validation and Analysis
Haindl, M., & Filip, J. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4902-6_9
Weighted Optimum Bit Allocations to Orthogonal Transforms for
Macq, B. M. M. (1992)
A New Digital Haiftoning and Data Hiding Designed with LMS Optimization
Guo, J.-M. (2006) · International Conference on Information, Communications & Signal Processing (ICICS) · doi:10.1109/icics.2005.1689204
The Collaboration of Noise Reduction and Human Vision System Models for a Visible
Tsai, M.-J., & Lin, C.-W. (2007)
E PERCEPTUAL INTERBAND CO LATION FOR CTAVE SUB AND CODING
Liu, C., & Wang, C.-N. (1998)
NSlDERATlONS OF THE VID COMPRESSION SYSTEM OF THE NEW DV CAMCORDER STANDARD
Rijckaert, A. M. A. (1997)
Bell, A. E., & Varma, K. M. (2006) · VTechWorks (Virginia Tech)
Visual Perception Based Objective Stereo Image Quality Assessment for 3D Video Communication
Jiang, G., Jiang, G., Mao, X., Yu, M., Yu, M., Peng, Z., & Shao, F. (2014) · Research Journal of Applied Sciences Engineering and Technology · doi:10.19026/rjaset.7.606
“Mannos gained CSF approximate curve through experiments (Mannos and Sakrison, 1974) and computed it by: Majority energy of image is concentrated in low-frequency including direct current component.”
MethodLearning based signal quality assessment for multimedia communications
Narwaria, M. (2012) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/50753
Gao, W., & Ma, S. (2014) · Springer eBooks · doi:10.1007/978-3-319-14243-2_8
A Modified Image Coder using HVS Characteristics
Tripathi, S., & Jain, R. (2003)
Signal processing approaches for appearance matching
Scoggins, R. K., & Moorhead, R. J., II (2003)
“Simple computational distortion measures, such as the MAD, cannot reliably predict the difference of the perceived quality of one image with another [43].”
BackgroundRate control in bi-level image coding
Tompkins, D. A. D. (2009) · cIRcle (University of British Columbia) · doi:10.14288/1.0065273
Blue Channel Replacement Technique for DCT-Compressed Image
Gupta, M., Yadav, P. S., & Bewerwal, A. (2012) · International Journal of Applied Information Systems · doi:10.5120/ijais12-450796
“One of several computational models which explain the CSF is proposed by Mannos-Sakrison [12].”
A Novel Image Quality Assessment Metric based on Image Gradient Vectors
Zhou, W., Jiang, G., Wang, X., Yu, M., Shao, F., & Peng, Z. (2012) · INTERNATIONAL JOURNAL ON Advances in Information Sciences and Service Sciences · doi:10.4156/aiss.vol4.issue18.19
“In the past three decades, many objective FR IQA methods have been put forward [3-4, 6-25], which can be generally classified into the following three main categories: Methods based on the statistic of image pixels, which use some mathematical statistic to measure the perceptual quality of the image, such as the mean…”
MethodMatsumoto, S., & Kawada, R. (1999) · The Journal of The Institute of Image Information and Television Engineers · doi:10.3169/itej.53.1199
Lee, I.-W., Kim, H., Oh, T., & Lee, S.-H. (2014) · 한국통신학회논문지 · doi:10.7840/kics.2014.39c.5.435
Minimizing Compression Artifacts for High Resolutions with Adaptive Quantization Matrices for HEVC
Prangnell, L., & Sanchez, V. (2016) · Warwick Research Archive Portal (University of Warwick) · doi:10.48550/arxiv.1609.06442
Image Fusion Algorithm Based on Morphological Wavelet and Contrast Sensitivity Functio
Lin, Y. (2015) · Journal of Information and Computational Science · doi:10.12733/jics20105407
Role of noise in human visual perception: A psychophysical study
Kundu, A., & Sarkar, S. (2014) · IOSR Journal of Pharmacy and Biological Sciences · doi:10.9790/3008-093293100
“(3) We also demonstrate that the qualitative nature of the detection sensitivity, as a function of frequency, is in good agreement with the human contrast sensitivity function measured in psychophysical experiments [21, 22].”
BackgroundMethodResultA New Research on Contrast Sensitivity Function Based on Three-Dimensional Space
Yang, J., Liu, Y., Wei, W., Meng, Q., Gao, Z., & Lin, Y. (2015) · Communications in computer and information science · doi:10.1007/978-3-662-48570-5_40
Learning Print Artifact Detectors
Nachlieli, H., Kogan, H., Awad, M., Shaked, D., & Shiffman, S. (2012) · Conference on Colour in Graphics Imaging and Vision · doi:10.2352/cgiv.2012.6.1.art00015
“[12] and [4], are based on the human visual models in the frequency domain (MTF), originally extracted for harmonic bands.”
BackgroundWu, H. R., Reibman, A. R., Lin, W., Pereira, F. M. B., & Hemami, S. S. (2013)
Low complexity in-loop prediction perceptual video coding for HEVC
Joshi, Y. G., Loo, J. K. K., Shah, P., Rahman, S., Tasiran, A., & Cosmas, J. (2016) · IEEE International Symposium on Broadband Multimedia Systems and Broadcasting (BMSB) · doi:10.1109/bmsb.2016.7521919
Allgemeine Methoden und Verfahren
Kazmierczak, H., Schärf, R., Lütjen, K., Sties, M., Pirsch, P., Bargel, B., Böhner, M., Dittel, R. H., Kreifelts, T., & Woetzel, G. (1980) · Springer eBooks · doi:10.1007/978-3-7091-2255-6_2
Ohtsuka, S. (1991) · The Journal of The Institute of Image Information and Television Engineers · doi:10.3169/itej1978.45.293
An adaptive digital watermark based on a wavelet tree stnucture using te human visual system
Sepsirisuk, K., Atsuta, K., & Kondo, S. (2006) · International Symposium on Communications and Information Technologies · doi:10.1109/iscit.2005.1567051
Hwang, J., Kikuchi, H., Muramatsu, S., & Shin, J. (2009) · International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS) · doi:10.1109/ispacs.2009.5383823
“The performance of the optimized error diffusion is evaluated by means of the weighted signal-to-noise ratio (WSNR) [ 7 , 8] and the Fourier power spectrum.”
MethodA new way of applying spatial filters and wavelets to reduce noise in medical images
Pawlovsky, A. P., & Hozaki, M. (2016) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2016.7848157
“To measure the level of denoising we used PSNR (Peak Signal Noise Ratio [17]) and SSIM (Structural Similarity Index [18]).”
MethodP‐89: Analysis of Mura related to Aperture Ratio Non‐uniformity from Pixel Design
You, J., Zhao, W., Wang, X., Zhang, B., Sun, X., Zhan, Y., Liu, J., Jia, Q., & Yao, J. (2017) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.11961
No noticeable difference evaluation of image data compression
Jang, E. S. (2016) · IEEE International Conference on Network Infrastructure and Digital Content (IC-NIDC) · doi:10.1109/icnidc.2016.7974626
A visual model for quality driven refinement of global illumination
Günther, R., Guthe, S., & Guthe, M. (2017) · ACM Symposium on Applied Perception · doi:10.1145/3119881.3119893
A No-reference IQA Metric Based on BEMD and Riesz Tansform
Yang, G., Liao, Y., Zhang, Q., Zhi, Y., Cao, J., & Li, D. (2017) · EAI International Conference on Mobile Multimedia Communications (MobiMedia) · doi:10.4108/eai.13-7-2017.2269980
Image quality evaluation based on saliency and feature similarity
Pan, W., Sun, X., Wang, X., Wang, L., Xu, T., & Yang, B. (2017) · IEEE Information Technology, Networking, Electronic and Automation Control Conference (ITNEC) · doi:10.1109/itnec.2017.8285100
Xu, H., & Jiang, M. (2018) · 3D Research · doi:10.1007/s13319-018-0184-9
Jayant, N. S., Johnston, J. D., & Safranek, R. J. (1995) · Elsevier eBooks · doi:10.1016/b978-0-08-091854-9.50008-7
Fast Single Image Dehazing via Positive Correlation
Li, B., Lai, Y., Wu, C., & Liu, Y. (2018) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2018.8546251
“3(b) show the comparison of PSNR and SSIM for each image.”
MethodInfluentialMathematical Preliminaries for Lossy Coding
Sayood, K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809474-7.00008-2
Research about Quality Estimation Method of Digitial Camera
Cho, S.-M. (2008) · journal of the moving image technology associon of korea · doi:10.34269/mitak.2008.1.10.005
Ubiquitous Scalable Graphics: An End-to-End Framework using Wavelets
Wu, F. (2008) · Digital WPI
Geometry description and mesh construction from medical imaging
Carlino, M. G., Ricka, P., Phan, M., Bertoluzza, S., Pennacchio, M., Patanè, G., & Spagnuolo, M. (2020) · ESAIM Proceedings and Surveys · doi:10.1051/proc/202067010
“In more challenging conditions (noisy data), one can resort to more and more sophisticated (and more computationally expensive) metrics, such as the structural similarity index (SSIM, [9, 45]), which independently measures the similarity of luminance, contrast and structure, the Human visual system distance (HVS) [28]…”
BackgroundThai, B. C., & Mokraoui, A. (2019) · doi:10.1109/ict.2019.8798770
“TMQI1 uses the CSF as introduced by Mannos and Sakrison [7] and fits to the data measured by Kelly [8].”
MethodZhu, Z.-Y., Li, J.-E., Hsieh, P.-Y., Su, J.-J., & Tien, C.-H. (2019) · SPIE Future Sensing Technologies · doi:10.1117/12.2542638
“The first step is applying multiple feature extraction algorithms to the input image, including the region of interests (ROI) extraction, the SEMU criteria, contrast sensitivity function (CSF) filtering, and ModelFest matching [6-8].”
MethodMathematical Preliminaries for Lossy Coding
Sayood, K. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-415796-5.00008-9
Analysis and Application of Optical Illusion Images
Wang, D., & Cao, P. (2020) · International Conference on Biomedical Signal and Image Processing (ICBIP) · doi:10.1145/3417519.3417554
A Detection Method for Definition Quality of Printed Matter
Xu, Y., Wang, H., & Zhang, B. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-0503-1_26
Image Fusion using Multi Resolution transforms with Human Visual System
Vadhi, R., & Veeraswamy, K. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1921/1/012005
“Mannos and Sakrison [20] derived a mathematical model of CSF for gray (or luminance) images. where F (in cycles/degree) is the spatial frequency is given as x F is the spatial frequency in horizontal direction. y F is the spatial frequency in vertical direction.”
BackgroundMethod
Metadata
- Authors
- Mannos, J., & Sakrison, D.
- Affiliations
- MIT Lincoln Laboratory (US)
- University of California, Berkeley (US)
- Venue
- IEEE Transactions on Information Theory
- Published
- 1974-07
- Volume
- 20
- Issue
- 4
- Pages
- 525-536
- ISSN
- 0018-9448 (ISSN-L)
- 1557-9654
- OpenAlex
- W2168078737
- Cited by
- 1,063
- References
- 26
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 14 · 2023: 21 · 2022: 23 · 2021: 25 · 2020: 22 · 2019: 26 · 2018: 31 · 2017: 37 · 2016: 36 · 2015: 40 · 2014: 38 · 2013: 39 · 2012: 43
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Information Theory (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Data Compression Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Video Quality Assessment
- Physical Sciences › Computer Science › Signal Processing › Video Coding and Compression Technologies
- Keywords
- rate-distortion theory, distortion measures, image compression, visual fidelity, subjective image quality, image transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.