The effects of a visual fidelity criterion of the encoding of images
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Shannon's rate-distortion function provides a potentially useful lower bound against which to compare the rate-versus-distortion performance of practical encoding-transmission systems. However, this bound is not applicable unless one can arrive at a numerically-valued measure of distortion which is in reasonable correspondence with the subjective evaluation of the observer or interpreter. We have attempted to investigate this choice of distortion measure for monochrome still images. This investigation has considered a class of distortion measures for which it is possible to simulate the optimum (in a rate-distortion sense) encoding. Such simulation was performed at a fixed rate for various measures in the class and the results compared subjectively by observers. For several choices of transmission rate and original images, one distortion measure was fairly consistently rated as yielding the most satisfactory appearing encoded images.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
Information Theory and Reliable Communication.
Lee, P. M., & Gallager, R. T. (1970) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344305 · Cited by 5,399
Information Theory and Reliable Communication
Bell, D. A. (1969) · Electronics and Power · doi:10.1049/ep.1969.0319 · Cited by 4,012
Application of fourier analysis to the visibility of gratings
Campbell, F. W., & Robson, J. G. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008574 · Cited by 3,019
Torgerson, W. S. (1958) · Medical Entomology and Zoology · Cited by 2,920
(1961) · Information and Control · doi:10.1016/s0019-9958(61)80064-8 · Cited by 2,875
LERNER, A. (1959) · American Journal of Psychiatry · doi:10.1176/ajp.116.2.190 · Cited by 1,002
The Psychophysics of Sensory Function
Stevens, S. S. (2012) · Sensory Communication · doi:10.7551/mitpress/9780262518420.003.0001 · Cited by 780
Orientational selectivity of the human visual system
Campbell, F. W., & Kulikowski, J. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008101 · Cited by 688
Research works printed but not linked: 5
- sakrison, 1970, Notes on Analog Communication
- van ness, 1965, The effects of wavelength and luminance on visual modulation transfer, Excerpta Medica— Int Congress, 183
- shannon, 1960, Coding theorems for a discrete source with a fidelity criterion, Information and Decision Processes, 93
- mannos, 1972, A class of fidelity criteria for the encoding of visual images
- gray, 0, Universal coding with a fidelity criterion, IEEE Trans Inform Theory
Cited by
Items 301–400 of 1,000
Dehazed Image Quality Evaluation: From Partial Discrepancy to Blind Perception
Zhou, W., Zhang, R., Li, L., Yue, G., Gong, J., Chen, H., & Liu, H. (2024) · IEEE Transactions on Intelligent Vehicles · doi:10.1109/tiv.2024.3356055 · Cited by 24
“H 1 ( f, ϕ ) and H 2 ( f, ϕ ) are the frequency response from a circularly symmetric Gaussian filter and the frequency response of a CSF model originally proposed in [52] and adjusted in [53].”
BackgroundJPEG-compliant perceptual coding for a grayscale image printing pipeline
Kam, R. A. V., Wong, P. W., & Gray, R. M. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.736675 · Cited by 20
“In this paper, we use the contrast sensitivity function (CSF) from Mannos and Sakrison’s HVS model [25], with one modification: the CSF is assumed to be flat from the location of the peak down to dc, instead of rolling off at the low”
MethodObjective assessment of visual acuity: a refined model for analyzing the sweep VEP
Straßer, T., Nasser, F., Langrová, H., Zobor, D., Lisowski, Ł., Hillerkuss, D., Sailer, C., Kurtenbach, A., & Zrenner, E. (2019) · Documenta Ophthalmologica · doi:10.1007/s10633-019-09672-z · Cited by 20
Improved data hiding in halftone images with cooperating pair toggling human visual system
Guo, J.-M. (2007) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20128 · Cited by 19
“The human visual system w can be obtained by psychophysical experiments (Mannos and Sakrison, 1974).”
BackgroundApplication of perceptual difference model on regularization techniques of parallel MR imaging
Huo, D., Xu, D., Liang, Z., & Wilson, D. L. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.018 · Cited by 19
FUNDAMENTAL REQUIREMENTS FOR PICTURE PRESENTATION
Cowlishaw, M. F. (1985) · Cited by 19
Psycho-visual based distortion measures for monochrome image and video compression
Chaddha, N., & Meng, T. H. Y. (2002) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.1993.342451 · Cited by 19
Cleemput, P. V. (2009) · Journal of research in nursing · doi:10.1177/1744987109106726 · Cited by 19
Design of Quantizers for Real-Time Hadamard-Transform Coding of Pictures
Mounts, F. W., Netravali, A. N., & Prasada, B. (1977) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1977.tb00151.x · Cited by 19
Debiased Mapping for Full-Reference Image Quality Assessment
Chen, B., Zhu, H., Zhu, L., Wang, S., Pan, J., & Wang, S. (2025) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2025.3535280 · Cited by 26
“The traditional error-sensitivity based methods attempt to map images to frequency domains by Fourier decomposition [1], Gabor decomposition [2], [3], local block discrete cosine transform [4] or wavelet transform [5], [6], based on the widely acknowledged principle that primary visual cortex presents different stimul…”
Forty years of color quantization: a modern, algorithmic survey
Celebi, M. E. (2023) · Artificial Intelligence Review · doi:10.1007/s10462-023-10406-6 · Cited by 25
Watermarking in halftone images with parity-matched error diffusion
Guo, J.-M., Pei, S., & Lee, H. (2010) · Signal Processing · doi:10.1016/j.sigpro.2010.06.017 · Cited by 18
“The human visual system w can be obtained by psychophysical experiments [33].”
BackgroundQuantization of Filter Bank Frame Expansions Through Moving Horizon Optimization
Quevedo, D. E., Bölcskei, H., & Goodwin, G. C. (2008) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2008.2008259 · Cited by 18
Keep Others from Peeking at Your Mobile Device Screen!
Chen, C., Lin, B.-Y., Wang, J., & Shin, K. G. (2019) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3300061.3300119 · Cited by 29
“The authors of [13] conducted experiments to determine humans’ perception sensitivity with respect to spatial frequencies.”
BackgroundAn algorithm for image quality assessment
Ivkovic, G., & Sankar, R. T. (2004) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2004.1326644 · Cited by 18
“HVS model developed in [ 8 ] uses cube root function to model this effect.”
MethodInfluentialDigital color image processing and psychophysics within the framework of a human visual model.
Faugeras, O. D. (1976) · Cited by 18
Structured spatial domain image and data comparison metrics
Sahasrabudhe, N., West, J. E., Machiraju, R., & Janus, M. (1999) · Visualization · doi:10.1109/visual.1999.809873 · Cited by 18
“Both [3] and [15] employed the Contrast Sensitivity Function (CSF) [8] to model the HVS. Williams and Uselton provide a good set of guidelines for measuring image quality in volume rendering [19].”
MethodA predictive classified vector quantizer and its subjective quality evaluation for X-ray CT images
Lee, H., Kim, Y., Riskin, E. A., Rowberg, A. H., & Frank, M. S. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387720 · Cited by 18
“There have been several studies in which human visual perception characteristics were applied to the design of lossy data compression systems [ 7 ], [12], [13].”
BackgroundAdaptive Structure and Texture Similarity Metric for Image Quality Assessment and Optimization
Ding, K., Zhong, R., Wang, Z., Yu, Y., & Fang, Y. (2023) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2023.3333208 · Cited by 24
“Pioneering research on IQA dates back half a century [24], with Mean Squared Error (MSE) serving as the predominant quantitative criterion for evaluating signal quality and fidelity.”
BackgroundJoint binocular energy-contrast perception for quality assessment of stereoscopic images
Ma, J., An, P., Shen, L., & Li, K. (2018) · Signal Processing Image Communication · doi:10.1016/j.image.2018.03.009 · Cited by 17
One Transform to Compute Them All: Efficient Fusion-Based Full-Reference Video Quality Assessment
Venkataramanan, A. K., Stejerean, C., Katsavounidis, I. X., & Bovik, A. C. (2023) · IEEE Transactions on Image Processing · doi:10.1109/tip.2023.3345227 · Cited by 24
Estimating just‐noticeable distortion for images/videos in pixel domain
Uzair, M., & Dony, R. D. (2017) · IET Image Processing · doi:10.1049/iet-ipr.2016.1120 · Cited by 17
Computer rendering and visual detection of orange peel
Konieczny, J., & Meyer, G. W. (2011) · Journal of Coatings Technology and Research · doi:10.1007/s11998-011-9378-2 · Cited by 17
MPEG Motion Picture Coding With Long-Term Constraint on Distortion Variation
Wang, K., & Woods, J. W. (2008) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2008.918442 · Cited by 17
Perceptual Quality of Light Field Images and Impact of Visualization Techniques
Paudyal, P., Battisti, F., Callet, P. L., Gutiérrez, J., & Carli, M. (2020) · IEEE Transactions on Broadcasting · doi:10.1109/tbc.2020.3034445 · Cited by 20
“The considered metrics are WSNR [74], PSNR-HVS [75], PSNR-HVS-M [76].”
Efficiency analysis for multi‐view spatially multiplexed autostereoscopic 2‐D/3‐D displays
Woodgate, G. J., & Harrold, J. (2007) · Journal of the Society for Information Display · doi:10.1889/1.2812987 · Cited by 17
Guo, J.-M., Pei, S., & Lee, H. (2007) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2007.911259 · Cited by 17
“(2) where the variables and represent the original gray level image and the corresponding halftone images in position (i,j), respectively; is the support region of the human visual coefficients and is the human visual coefficient at , which can be obtained by psychophysical experiments [23], [24].”
BackgroundSun, Z. H. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.863023 · Cited by 17
Fidelity of Graphics Reconstructions: A Psychophysical Investigation
McNamara, A., Chalmers, A. G., Trościanko, T., & Reinhard, E. (1998) · Eurographics · doi:10.1007/978-3-7091-6453-2_22 · Cited by 17
“The following image comparison metrics were derived from [3, 5, 8] in a study which compared real and synthetic images by Rushmeier t al [9].”
BackgroundMethodFeatures for Automated Quality Assessment of Digitally Transmitted Video
Wolf, S. (1990) · doi:10.70220/wwbfh40p · Cited by 17
Valentine, C., Wilkins, A. J., Mitcheltree, H., Penacchio, O., Beckles, B., & Hosking, I. M. (2025) · Buildings · doi:10.3390/buildings15132208 · Cited by 17
Toward a blind image quality evaluator in the wild by learning beyond human opinion scores
Wang, Z., Tang, Z., Zhang, J., & Fang, Y. (2023) · Pattern Recognition · doi:10.1016/j.patcog.2022.109296 · Cited by 23
Lower indoor spatial frequency increases the risk of myopia in children
Li, D., Dong, X., Yang, J., Lança, C., Grzybowski, A. E., & Pan, C. (2024) · British Journal of Ophthalmology · doi:10.1136/bjo-2024-325888 · Cited by 16
“(Eye sensitivity 39 dopamine synthesis and release 31 ). and AL, CR and AL/CR, higher interindividual variability has been observed in SE compared with the less variable AL and AL/CR. 37 Additionally, while elongation of the AL can alter the eye’s shape, changes in CR and lens refraction can…”
Full Reference Printed Image Quality: Measurement Framework and Statistical Evaluation
Eerola, T., Lensu, L. T., Kalviainen, H. A., Kämäräinen, J., Leisti, T., Nyman, G., Halonen, R., & Oittinen, P. T. (2010) · Journal of Imaging Science and Technology · doi:10.2352/j.imagingsci.technol.2010.54.1.010201 · Cited by 21
“The approach was first introduced by Mannos and Sakrison.38 Other popular HVS error based methods are the VDP by Daly18 and the Sarnoff visual discrimination model.19 A typical scheme for computing HVS error-based QA algorithms consists of the following steps: preprocessing, contrast sensitivity function (CSF) filteri…”
MethodEnhancing retinal images by extracting structural information
Molodij, G., Ribak, E. N., Glanc, M., & Chènegros, G. (2013) · Optics Communications · doi:10.1016/j.optcom.2013.10.011 · Cited by 17
Example-Based Video Stereolization With Foreground Segmentation and Depth Propagation
Wang, L., & Jung, C. (2014) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2014.2341599 · Cited by 17
“To assess the visual quality of the estimated depth maps, we utilize three full-reference image quality assessments such as peak signal to noise ratio (PSNR) [36], visual information fidelity (VIF) [37], and structural similarity index (SSIM) [38].”
BackgroundMethodStereo Picture Quality Estimation Based on a Multiple Channel HVS Model
Shen, L., Yang, J., & Zhang, Z. (2009) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp.2009.5301128 · Cited by 16
“For the human visual system, it is well-known [5] that the receptive fields in the visual cortex are characterized as being localized, oriented, and bandpass.”
BackgroundVQA-CPC: a novel visual quality assessment metric of color point clouds
Hua, L., Yu, M., Jiang, G., He, Z., & Lin, Y. (2020) · Optoelectronic Imaging and Multimedia Technology · doi:10.1117/12.2573686 · Cited by 18
“The PSNR model (p2point) metrics does not consider the global structure information of point clouds.”
BackgroundMethodInfluentialQR code beautification by instance segmentation (IS-QR)
Tsai, M.-J., & Peng, S.-L. (2022) · Digital Signal Processing · doi:10.1016/j.dsp.2022.103887 · Cited by 16
Knowledge-Guided Blind Image Quality Assessment With Few Training Samples
Song, T., Li, L., Wu, J., Yang, Y., Li, Y., Guo, Y., & Shi, G. (2022) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2022.3233244 · Cited by 19
“Extensive studies have shown that the HVS is insensitive to high-frequency information of images [35], which has been the foundation of many image processing tasks such as image compression (JPEG/JPEG2000 standards are based on CSC).”
BackgroundInfluentialParallel blind digital image watermarking in spatial and frequency domains
Lenarczyk, P., & Piotrowski, Z. (2013) · Telecommunication Systems · doi:10.1007/s11235-013-9734-x · Cited by 16
“2 The graph of the Contrast Sensitivity Function [35] Sensitivity refers to the eyes’ response to a direct stimulus.”
BackgroundMethodInfluentialVisual sensitivity to color-varying stimuli
Rajala, S. A., Trussell, H. J., & Krishnakumar, B. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.135983 · Cited by 16
Using geometric moments to explain human letter recognition near the acuity limit
Liu, L., Klein, S. A., Xue, F., Zhang, J. Y., & Yu, C. (2009) · Journal of Vision · doi:10.1167/9.1.26 · Cited by 16
“A 3 - parameter model ( Mannos & Sakrison , 1974 ) CSFð f Þ ¼ afe jðbf Þ c ; ðA1Þ was used to fit the CSF .”
Image anonymization for PRNU forensics: A set theoretic framework addressing compression resilience
Elliethy, A. S., & Gaurav Sharma, A. (2016) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2016.7533092 · Cited by 15
Digital Image Multiresolution Watermark Based on Human Visual System Using Error Correcting Code
Hsieh, C.-T., & Wu, Y. (2001) · doi:10.6180/jase.2001.4.3.07 · Cited by 15
Aerial Image Series Quality Assessment
Zhang, H., Li, B., Zhang, J., & Xu, F. (2014) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/17/1/012183 · Cited by 15
See ColOr: Seeing Colours with an Orchestra
Deville, B., Bologna, G., Vinckenbosch, M., & Pun, T. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-00437-7_10 · Cited by 19
Young, L. K., Love, G. D., & Smithson, H. E. (2013) · Vision Research · doi:10.1016/j.visres.2013.06.007 · Cited by 17
“Mannos and Sakrison (1974) proposed an analytical model of the CSF,”
BackgroundSubpixel rendering for the pentile display based on the human visual system
Chae, S.-H., Yoo, C.-H., Sun, J.-Y., Kang, M.-C., & Ko, S.-J. (2017) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2017.015103 · Cited by 14
Design of Tone-Dependent Color-Error Diffusion Halftoning Systems
Monga, V., Damera-Venkata, N., & Evans, B. L. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.884923 · Cited by 15
“This constraint ensures that the error fllter eliminates quantization noise at DC where the human visual system is most sensitive [ 34 ].”
BackgroundTSAI, M.-J., & Lin, C.-F. (2008) · IEICE Transactions on Fundamentals of Electronics Communications and Computer Sciences · doi:10.1093/ietfec/e91-a.6.1426 · Cited by 15
A Perceptually Motivated Three-Component Image Model
Farvardin, N., & Ran, X. (1996) · Springer eBooks · doi:10.1007/978-1-4613-1337-3_9 · Cited by 15
Structured spatial domain image and data comparison metrics
Sahasrabudhe, N., West, J. E., Machiraju, R., & Janus, M. (1999) · doi:10.5555/319351.319362 · Cited by 15
Customized JPEG compression for grayscale printing
Kam, R. A. V., & Wong, P. W. (2002) · DCC · doi:10.1109/dcc.1994.305923 · Cited by 15
Perceptually optimized 3D transmission over wireless networks
Cheng, I., & Basu, A. (2005) · ACM SIGGRAPH Conference (SIGGRAPH) · doi:10.1145/1187335.1187338 · Cited by 15
“However, past research has shown that MSE does not correlate well to perceived quality based on human evaluation [61].”
BackgroundJain, A. K., Farrelle, P. M., & Algazi, V. R. (1984) · Elsevier eBooks · doi:10.1016/b978-0-12-236760-1.50010-9 · Cited by 15
Optical Performance of Multifocal Soft Contact Lenses via a Single‐Pass Method
Bakaraju, R. C., Ehrmann, K., Falk, D., Ho, A., & PAPAS, E. B. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e318264f3e9 · Cited by 22
No-Reference Quality Assessment of Noise-Distorted Images Based on Frequency Mapping
Yang, G., Liao, Y., Zhang, Q., Li, D., & Yang, W. T. (2017) · IEEE Access · doi:10.1109/access.2017.2764126 · Cited by 14
“This paper uses the CSF proposed by Mannos and Sakrison [52] as the weighting.”
MethodKim-Lee, H.-J., Hong, S. W., Kim, D. K., Kim, J., Kim, H. S., Chung, S.-W., Cho, E.-H., Kim, H., & Lee, B.-K. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-00203-4 · Cited by 16
Automated Mottling Assessment of Colored Printed Areas
Sadovnikov, A., Lensu, L. T., & Kalviainen, H. A. (2007) · Springer eBooks · doi:10.1007/978-3-540-73040-8_63 · Cited by 14
“The implementation of the method uses Mannos CSF defined as [15]: Mannos CSF formulation is in cycles per degree (cpd) units and has a maximum at 8 cpd (see Fig.”
MethodPerceptually lossless High Dynamic Range image compression with JPEG 2000
Zhang, Y., Reinhard, E., & Bull, D. (2012) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2012.6467045 · Cited by 14
“Mannos and Sakrison [11] originally presented 1057978-1-4673-2533-2/12/$26.00 ©2012 IEEE ICIP 2012 a CSF model for grayscale images as a non-linear transformation followed by a Modulation Transfer Function (MTF), as defined in the following.”
InfluentialContinuous Phase-Modulated Halftones
Oztan, B., & Gaurav Sharma, A. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028367 · Cited by 14
Contrast sensitivity in images of natural scenes
Triantaphillidou, S., Jarvis, J., Psarrou, A., & Gupta, G. (2019) · Signal processing. Image communication · doi:10.1016/j.image.2019.03.002 · Cited by 15
“Some of the most predominant are: Mannos and Sakrison [81], Kelly [4], Daly [62], Movshon and Kiorpes [82], Barten [5,83] and ModelFest [6,84].”
BackgroundModels of contrast sensitivity in human vision
Thomas, C. W., Gilmore, G. C., & Royer, F. L. (1993) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/21.256556 · Cited by 14
Objective quality measures for halftoned images
Nilsson, F. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.002151 · Cited by 14
Learning optimal integration of arbitrary features in a perceptual discrimination task
Michel, M. M., & Jacobs, R. A. (2008) · Journal of Vision · doi:10.1167/8.2.3 · Cited by 16
Sparsity constrained regularization for multiframe image restoration
Shankar, P. M., & Neifeld, M. A. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.001199 · Cited by 13
Noise considerations in digital image processing hardware
Billingsley, F. C. (1979) · Topics in applied physics · doi:10.1007/3-540-09339-7_20 · Cited by 14
Making Progressive Transmission Adaptive
Hofmann, W., & Troxel, D. E. (1986) · IEEE Transactions on Communications · doi:10.1109/tcom.1986.1096623 · Cited by 14
The transform image codec based on fuzzy control and human visual system
Wen, K.-A., Lu, C.-Y., & Tsai, M.-C. (1995) · IEEE Transactions on Fuzzy Systems · doi:10.1109/91.413231 · Cited by 14
Tone Mapping Techniques and Color Image Difference in Global Illumination
Matković, K. (1997) · reposiTUm (TU Wien) · doi:10.2312/8132 · Cited by 14
Atmospheric Turbulence Removal in Long-Range Imaging Using a Data-Driven-Based Approach
Fazlali, H., Shirani, S., BradforSd, M., & Kirubarajan, T. (2022) · International Journal of Computer Vision · doi:10.1007/s11263-022-01584-x · Cited by 13
“We calculated the average peak signal-to-noise ratio (PSNR) (Mannos and Sakrison 1974) and structural similarity index (SSIM) (Wang et al. 2004) as the evaluation metrics for comparison.”
MethodVision models for image quality assessment: one is not enough
Brémond, R., Tarel, J., Dumont, E., & Hautiere, N. (2010) · Journal of Electronic Imaging · doi:10.1117/1.3495989 · Cited by 14
Transforms for Image and Video Coding
Bull, D. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-405906-1.00005-2 · Cited by 15
One-dimensional least-squares model-based halftoning
Neuhoff, D. L., Pappas, T. N., & Seshadri, N. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.001707 · Cited by 13
Colorant-based direct binary search halftoning
Lee, J.-H., & Allebach, J. P. (2002) · Journal of Electronic Imaging · doi:10.1117/1.1507598 · Cited by 13
MODELING SELECTIVE PERCEPTION OF COMPLEX, NATURAL SCENES
Canosa, R. L. (2005) · International Journal of Artificial Intelligence Tools · doi:10.1142/s0218213005002089 · Cited by 13
“Equation 6 gives the contrast sensitivity function used to find the weights (from Manno and Sakrison 1974 ).”
MethodSecond-generation image coding
Black, N. D., Millar, R. J., Kunt, M., Reid, M., & Ziliani, F. (2000) · Advances in imaging and electron physics · doi:10.1016/s1076-5670(00)80026-9 · Cited by 13
Perceptual-error measure and its application to sampled and interpolated single-edged images
Nijenhuis, M., & Blommaert, F. J. J. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002111 · Cited by 13
Design considerations of the video compression system of the new DV camcorder standard
de With, P. H. N., & Rijckaert, A. M. A. (1997) · IEEE Transactions on Consumer Electronics · doi:10.1109/30.642384 · Cited by 13
Image quality criterion based on the cancellation of the masked noise
Comes, S., Bruyndonckx, O., & Macq, B. M. M. (2002) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1995.480102 · Cited by 13
Quaternion attention-based JND model for macrophotography image watermarking
Wan, W., Li, X., Li, J., Xu, M., Lv, H., & Sun, J. (2024) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2024.108607 · Cited by 12
Effect of appearance on perception of deformation
Han, D., & Keyser, J. (2015) · ACM SIGGRAPH/Eurographics Symposium on Computer Animation (SCA) · doi:10.1145/2786784.2786797 · Cited by 14
DCT-based objective quality assessment metric of 2D/3D image
Liu, X., Sun, C., & Yang, L. T. (2013) · Multimedia Tools and Applications · doi:10.1007/s11042-013-1698-z · Cited by 12
“proposed a calculation equation to reflect the performance of CSF [17].”
BackgroundA Multi-Attribute Blind Quality Evaluator for Tone-Mapped Images
Mahmoudpour, S., & Schelkens, P. (2019) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2019.2950570 · Cited by 15
“[25] proposed a CSF model with a single threshold for all luminance conditions from very low to very high luminance levels.”
BackgroundRate Bounds on SSIM Index of Quantized Image DCT Coefficients
Channappayya, S. S., Bovik, A. C., Heath, R. W., & Caramanis, C. (2008) · DCC · doi:10.1109/dcc.2008.91 · Cited by 12
“Image coding algorithms that are optimized for perceptual distortion measures have been proposed by several authors and have become a part of image coding standards [9, 14, 10].”
Background3D DFT-based video watermarking using perceptual models
Lee, Y.-Y., Jung, H.-S., & Lee, S.-U. (2006) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2003.1562600 · Cited by 12
Perceptual model based data embedding in medical images
Dandapat, S., Chutatape., O., & Krishnan, S. M. (2005) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2004.1421563 · Cited by 12
Interesting properties of the discrete cosine transform
Hou, H. S., Tretter, D. R., & Vogel, M. J. (1992) · Journal of Visual Communication and Image Representation · doi:10.1016/1047-3203(92)90031-n · Cited by 12
No-Reference Metric Design With Machine Learning for Local Video Compression Artifact Level
Vink, J. P., & de Haan, G. (2010) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2010.2055832 · Cited by 12
“In area A of the image, indicates large differences, whereas in this part of the image the compression artifacts are hardly visible.”
BackgroundVisible Edges Thresholding: a HVS based Approach
Hautière, N., & Aubert, D. (2006) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2006.1177 · Cited by 12
“Figure 4. CSF (—) and CTF (– –) of the Human Visual System, proposed by Mannos [ 6 ].”
BackgroundMethodEwe, M. T. S., Chiu, G. T. ‐., Grice, J., Allebach, J. P., Chan, C. S., & Foote, W. (2002) · Journal of Imaging Science and Technology · doi:10.2352/j.imagingsci.technol.2002.46.5.art00006 · Cited by 12
Sampling Theory in Signal and Image Processing
Fesquet, L., & Torrésani, B. (2011) · HAL · Cited by 13
Colour quantisation through dithering techniques
Alasseur, C., Constantinides, A. G., & Husson, L. (2004) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2003.1247000 · Cited by 12
“The noise transfer function of the Human Vision System (HVS) has been established through psychological experiments [5].”
BackgroundFoundations for Measuring Volume Rendering Quality
Williams, P. L., Uselton, S. P., & Chancellor, M. K. (1997) · NASA Technical Reports Server (NASA) · Cited by 12
Synthetic Aperture Radar Image Coding
Baxter, R. A. (1998) · Cited by 12
Theoretical Performance of Entropy-Encoded DPCM
Algazi, V. R., & DeWitte, J. T. (1982) · IEEE Transactions on Communications · doi:10.1109/tcom.1982.1095554 · Cited by 12
A progressive scheme for digital image halftoning, coding of halftones, and reconstruction
Kollias, S., & Anastassiou, D. (1992) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.138999 · Cited by 12
Subband coding using human visual characteristics for image signals
Kim, J., Lee, H. J., & Choi, J. S. (1993) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.210544 · Cited by 12
How Reliable is the Pattern Adaptation Technique? A Modeling Study
Hegdé, J. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00216.2009 · Cited by 11
“The green line denotes the human contrast sensitivity function (CSF) (Mannos and Sakrison 1974) with which the responses of individual units were scaled.”
BackgroundMethod
Metadata
- Authors
- Mannos, J., & Sakrison, D.
- Affiliations
- MIT Lincoln Laboratory (US)
- University of California, Berkeley (US)
- Venue
- IEEE Transactions on Information Theory
- Published
- 1974-07
- Volume
- 20
- Issue
- 4
- Pages
- 525-536
- ISSN
- 0018-9448 (ISSN-L)
- 1557-9654
- OpenAlex
- W2168078737
- Cited by
- 1,063
- References
- 26
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 14 · 2023: 21 · 2022: 23 · 2021: 25 · 2020: 22 · 2019: 26 · 2018: 31 · 2017: 37 · 2016: 36 · 2015: 40 · 2014: 38 · 2013: 39 · 2012: 43
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Information Theory (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Data Compression Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Video Quality Assessment
- Physical Sciences › Computer Science › Signal Processing › Video Coding and Compression Technologies
- Keywords
- rate-distortion theory, distortion measures, image compression, visual fidelity, subjective image quality, image transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.