An Implantable Telemetry Platform System for In Vivo Monitoring of Physiological Parameters
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes a microcontroller-based multichannel telemetry system, suitable for in vivo monitoring of physiological parameters. The device can digitalize and transmit up to three analog signals coming from different sensors. The telemetry transmission is obtained by using a carrier frequency of 433.92 MHz and an amplitude-shift keying modulation. The signal data rate is 13 kb/s per channel. The digital microcontroller provides good flexibility and interesting performance, such as the threshold monitoring, the transmission error detection, and a low power consumption, thanks to the implementation of a sleep mode. The small overall size (less than 1 cm3), the power density compatible with current regulations for the design of implantable devices, and the dedicated packaging make the system suitable for in vivo monitoring in humans. The design, fabrication, operation, packaging, and performance of the system are described in this paper. An in vivo pressure monitoring case study is described as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Cited by
A survey on ambient-assisted living tools for older adults
Rashidi, P., & Mihailidis, A. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2234129 · Cited by 1,128
A review of smart homes—Present state and future challenges
Chan, M., Estève, D., Escriba, C., & Campo, E. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.02.001 · Cited by 1,007
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Health monitoring through wearable technologies for older adults: Smart wearables acceptance model
Li, J., Ma, Q., Chan, A. H., & Man, S. S. (2019) · Applied Ergonomics · doi:10.1016/j.apergo.2018.10.006 · Cited by 436
Metadata
- Authors
- Valdastri, P., Menciassi, A., Arena, A., Caccamo, C., & Dario, P.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2004-09
- Volume
- 8
- Issue
- 3
- Pages
- 271-278
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2106872146
- Cited by
- 117
- References
- 1
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Implantable Telemetry Platform System for In Vivo Monitoring of Physiological Parameters. https://app.cochat.ai/papers/10.1109/titb.2004.834389
- The paper
- Valdastri, P., Menciassi, A., Arena, A., Caccamo, C., & Dario, P. (2004). An Implantable Telemetry Platform System for In Vivo Monitoring of Physiological Parameters. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2004.834389
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.