The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Parallel Multiscale Feature Extraction and Region Growing: Application in Retinal Blood Vessel Detection
Abstract
This paper presents a parallel implementation based on insight segmentation and registration toolkit for a multiscale feature extraction and region growing algorithm, applied to retinal blood vessels segmentation. This implementation is capable of achieving an accuracy (Ac) comparable to its serial counterpart (about 92%), but 8 to 10 times faster. In this paper, the Ac of this parallel implementation is evaluated by comparison with expert manual segmentation (obtained from public databases). On the other hand, its performance is compared with previous published serial implementations. Both these characteristics make this parallel implementation feasible for the analysis of a larger amount of high-resolution retinal images, achieving a faster and high-quality segmentation of retinal blood vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Validity of the single processor approach to achieving large scale computing capabilities
Amdahl, G. M. (1967) · Proceedings of the April 18-20, 1967, spring joint computer conference on - AFIPS '67 (Spring) · doi:10.1145/1465482.1465560 · Cited by 4,339
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Zhao, Y., Rada, L., Chen, K., Harding, S. P., & Zheng, Y. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2409024 · Cited by 391
An approach to localize the retinal blood vessels using bit planes and centerline detection
Fraz, M. M., Barman, S. A., Remagnino, P., Hoppe, A., Basit, A., Uyyanonvara, B., Rudnicka, A. R., & Owen, C. G. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.08.009 · Cited by 340
Metadata
- Authors
- Palomera-Perez, M. A., Martinez-Perez, M. E., Benitez-Perez, H., & Ortega-Arjona, J. L.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-03
- Volume
- 14
- Issue
- 2
- Pages
- 500-506
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2104195344
- Cited by
- 165
- References
- 3
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parallel Multiscale Feature Extraction and Region Growing: Application in Retinal Blood Vessel Detection. https://app.cochat.ai/papers/10.1109/titb.2009.2036604
- The paper
- Palomera-Perez, M. A., Martinez-Perez, M. E., Benitez-Perez, H., & Ortega-Arjona, J. L. (2010). Parallel Multiscale Feature Extraction and Region Growing: Application in Retinal Blood Vessel Detection. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2009.2036604
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.