Comparative Evaluation of Susceptibility to Motion Artifact in Different Wearable Systems for Monitoring Respiratory Rate
Open accessAbstract
The purpose of this study is to comparatively evaluate the performance of different wearable systems based on indirect breathing monitoring in terms of susceptibility to motion artifacts. These performances are compared with direct respiratory measurements using a spirometer, which is accurate, reliable, and less sensitive to movement artifacts, but cannot be integrated into truly wearable form. Experiments were carried out on four indirect methods implemented into wearable systems, inductive plethysmography, impedance plethysmography, piezoresistive pneumography, and piezoelectric pneumography, to ascertain the performance of each of them in terms of noise due to movement artifacts, as well as to study the effects of different movements or gestures during each test. A group of volunteers was asked to wear all of the breath monitoring systems simultaneously along with the face mask of the spirometer while carrying out four physical exercises in a gym under controlled conditions. Data are analyzed in the time and frequency domain to estimate the frequency respiration from each wearable system and compare it with those of the spirometer. Results confirmed that all the wearable systems are somehow affected by movement artifacts, but statistical investigation showed that for most of the physical exercises, three out of four, piezoelectric pneumography provided best performance in terms of robustness and reduced susceptibility to movement artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The analysis showed that piezoelectric pneumography performs better than spirometry.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [29]
In the citing paper
“A comparative analysis of different wearable systems for monitoring respiratory function was presented by Lanata et al. [29].”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Goldstein, H. (2010) · Wiley series in probability and statistics · doi:10.1002/9780470973394 · Cited by 1,581
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
Self-citationSchuster, A. (1898) · Terrestrial Magnetism and Atmospheric Electricity · doi:10.1029/tm003i001p00013 · Cited by 641
Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing
Ferrigno, G., & Pedotti, A. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325627 · Cited by 580
Principles of Applied Biomedical Instrumentation.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-83-6-924_2 · Cited by 561
Ambulatory measurement of respiratory sinus arrhythmia and respiration rate
de Geus, E. J. C., Willemsen, G. A. H. M., Klaver, C. H. A. M., & van Doornen, L. J. P. (1995) · Biological Psychology · doi:10.1016/0301-0511(95)05137-6 · Cited by 328
Movements of the thoracic cage and diaphragm in respiration*
Wade, O. L. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005099 · Cited by 278
Performance Evaluation of Sensing Fabrics for Monitoring Physiological and Biomechanical Variables
Scilingo, E. P., Gemignani, A., Paradiso, R., Taccini, N., Ghelarducci, B., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854506 · Cited by 247
Self-citationLmberis, A., & Dittmar, A. (2007) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2007.364926 · Cited by 194
Flagged first, then by citations
Research works printed but not linked: 3
- milledge, 1977, inductive plethysmographya new respiratory transducer, J Physiol, 267, 4
- birkhoff, 1965, piecewise polynomial interpolation and approximation, Proc Gen Motors Symp, 164
- snedecor, 1989, Statistical Methods
Cited by
Sorted by citations
Items 101–111 of 111
System-on-a-chip pulse radar for contactless motion sensing in human–machine smart interfaces
Zito, D., & Pepe, D. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.014
Wu, D., Zheng, J., Wu, H., Wang, W., Silva, I., & Zhang, Z. (2014) · Springer eBooks
Non-contact Vital Signs Monitoring through Visible Light SensingPreprint
Abuella, H., & Ekin, S. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.05408
Alghorani, Y., & Ikki, S. (2020) · doi:10.36227/techrxiv.12107163.v2
(2015) · CRC Press eBooks · doi:10.1201/b19358-2
Alghorani, Y., & Ikki, S. (2020) · doi:10.36227/techrxiv.12923891.v1
Development of a Stand-alone Portable Respiratory Rate Monitor Using a Doppler Radar
Katoh, M., Kanazawa, T., Abe, Y., Sun, G., & Matsui, T. (2023) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.143.922
Development of a Novel Ventilation Estimation Model Based on Convolutional Neural Network (CNN)
Chu, J., Baik, J., Jeong, K., Jung, S., Park, Y.-J., & Lee, H. (2025) · The Journal of Korea Robotics Society · doi:10.7746/jkros.2025.20.1.138
van der Meiden, J. (2025) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3714394.3750711
Metadata
- Authors
- Lanatà, A., Scilingo, E. P., Nardini, E., Loriga, G., Paradiso, R., & De-Rossi, D.
- Affiliations
- University of Pisa (IT)
- Smartex (Italy) (IT)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-03
- Volume
- 14
- Issue
- 2
- Pages
- 378-386
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2123350533
- Cited by
- 111
- References
- 24
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 3 · 2023: 7 · 2022: 5 · 2021: 9 · 2020: 6 · 2019: 10 · 2018: 8 · 2017: 4 · 2016: 4 · 2015: 9 · 2014: 14 · 2013: 11 · 2012: 8
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Florence Research (University of Florence) (submittedVersion, other-oa)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- respiratory rate estimation, wearable sensors, motion artifacts, respiratory inductance plethysmography, impedance plethysmography, spirometer, physical activity, artifact robustness, frequency domain analysis
- MeSH terms
- Adult, Clothing, Female, Humans, Male, Motor Activity, Plethysmography, Signal Processing, Computer-Assisted, Spirometry, Artifacts, Monitoring, Ambulatory, Statistics, Nonparametric, Respiratory Rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review