The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array
Open accessAbstract
Spatial and temporal plantar pressure distributions are important and useful measures in footwear evaluation, athletic training, clinical gait analysis, and pathology foot diagnosis. However, present plantar pressure measurement and analysis systems are more or less uncomfortable to wear and expensive. This paper presents an in-shoe plantar pressure measurement and analysis system based on a textile fabric sensor array, which is soft, light, and has a high-pressure sensitivity and a long service life. The sensors are connected with a soft polymeric board through conductive yarns and integrated into an insole. A stable data acquisition system interfaces with the insole, wirelessly transmits the acquired data to remote receiver through Bluetooth path. Three configuration modes are incorporated to gain connection with desktop, laptop, or smart phone, which can be configured to comfortably work in research laboratories, clinics, sport ground, and other outdoor environments. A real-time display and analysis software is presented to calculate parameters such as mean pressure, peak pressure, center of pressure (COP), and shift speed of COP. Experimental results show that this system has stable performance in both static and dynamic measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
Cited by
Foot Plantar Pressure Measurement System: A Review
Abdul Razak, A. H., Zayegh, A., Begg, R. K., & Wahab, Y. (2012) · Sensors · doi:10.3390/s120709884 · Cited by 817
Review of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Self-citationSmart Insole: A Wearable Sensor Device for Unobtrusive Gait Monitoring in Daily Life
Lin, F., Wang, A., Zhuang, Y., Tomita, M. R., & Xu, W. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2585643 · Cited by 265
Najafi, B., Ron, E., Enriquez, A., Marin, I., Razjouyan, J., & Armstrong, D. G. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816689105 · Cited by 100
Aqueveque, P., Germany, E., Osorio, R., & Pastene, F. (2020) · Sensors · doi:10.3390/s20030656 · Cited by 63
Metadata
- Authors
- Shu, L., Hua, T., Wang, Y., Li, Q., Feng, D. D., & Tao, X.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-05
- Volume
- 14
- Issue
- 3
- Pages
- 767-775
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2139973231
- Cited by
- 416
- References
- 1
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array. https://app.cochat.ai/papers/10.1109/titb.2009.2038904
- The paper
- Shu, L., Hua, T., Wang, Y., Li, Q., Feng, D. D., & Tao, X. (2010). In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2009.2038904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.