Textile Technology for the Vital Signs Monitoring in Telemedicine and Extreme Environments
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper illustrates two extensive applications of a smart garment we previously developed for the monitoring of ECG, respiration, and movement. In the first application, the device, named Maglietta Interattiva Computerizzata (MagIC), was used for the home monitoring of cardiac patients. The used platform included MagIC for signals collection, a touchscreen computer with a dedicated software for data handling, and a universal mobile telecommunications system (UMTS) dongle for data transmission, via email, to three cardiologists. Three patients daily-performed 3-min telemonitoring sessions for 30 days by using the platform. The whole system behaved correctly in 85 out of 90 sessions. In five instances, a second session was required due to UMTS traffic congestion. Only in three sessions, cardiologists asked the patient to repeat the acquisition because of poor signal quality. In the second application, MagIC was used to evaluate the effects of high-altitude hypoxia on sleep and 24 h daily life in 30 healthy subjects at 3500 and 5400 m above sea level on Mount Everest slopes. The use of MagIC garment was reported to be simple and requiring short instrumentation time even in the demanding expedition environment. The signal quality was adequate in 111 out of 115 recordings and 90% of the subjects found the vest comfortable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
Cited by
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
Fernández-Caramés, T., & Fraga-Lamas, P. (2018) · Electronics · doi:10.3390/electronics7120405 · Cited by 359
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Energy Harvesting For Wearable Devices: A Review
Chong, Y.-W., Ismail, W., Ko, K., & Lee, C.-Y. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2925638 · Cited by 263
Metadata
- Authors
- Di Rienzo, M., Meriggi, P., Rizzo, F., Castiglioni, P., Lombardi, C., Ferratini, M., & Parati, G.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-05
- Volume
- 14
- Issue
- 3
- Pages
- 711-717
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2149532323
- Cited by
- 88
- References
- 1
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Textile Technology for the Vital Signs Monitoring in Telemedicine and Extreme Environments. https://app.cochat.ai/papers/10.1109/titb.2010.2048921
- The paper
- Di Rienzo, M., Meriggi, P., Rizzo, F., Castiglioni, P., Lombardi, C., Ferratini, M., & Parati, G. (2010). Textile Technology for the Vital Signs Monitoring in Telemedicine and Extreme Environments. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2010.2048921
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.