Automated Recognition of Obstructive Sleep Apnea Syndrome Using Support Vector Machine Classifier
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Obstructive sleep apnea (OSA) is a common sleep disorder that causes pauses of breathing due to repetitive obstruction of the upper airways of the respiratory system. The effect of this phenomenon can be observed in other physiological signals like the heart rate variability, oxygen saturation, and the respiratory effort signals. In this study, features from these signals were extracted from 50 control and 50 OSA patients from the Sleep Heart Health Study database and implemented for minute and subject classifications. A support vector machine (SVM) classifier was used with linear and second-order polynomial kernels. For the minute classification, the respiratory features had the highest sensitivity while the oxygen saturation gave the highest specificity. The polynomial kernel always had better performance and the highest accuracy of 82.4% (Sen: 69.9%, Spec: 91.4%) was achieved using the combined-feature classifier. For subject classification, the polynomial kernel had a clear improvement in the oxygen saturation accuracy as the highest accuracy of 95% was achieved by both the oxygen saturation (Sen: 100%, Spec: 90.2%) and the combined-feature (Sen: 91.8%, Spec: 98.0%). Further analysis of the SVM with other kernel types might be useful for optimizing the classifier with the appropriate features for an OSA automated detection algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“RR intervals were extracted from the ECG signals using the Pan–Tompkins algorithm [13].”
Method
Cited by
O'Reilly, C., Gosselin, N., Carrier, J., & Nielsen, T. (2014) · Journal of Sleep Research · doi:10.1111/jsr.12169 · Cited by 356
A Systematic Review of Detecting Sleep Apnea Using Deep Learning
Mostafa, S. S., Mendonça, F., G. Ravelo-García, A., & Morgado-Dias, F. (2019) · Sensors · doi:10.3390/s19224934 · Cited by 182
Hang, L.-W., Wang, H.-L., Chen, J.-H., Hsu, J.-C., Lin, H.-H., Chung, W.-S., & Chen, Y.-F. (2015) · BMC Pulmonary Medicine · doi:10.1186/s12890-015-0017-z · Cited by 115
“[23] adopted linear kernel and secondorder polynomial kernel to design the SVM classifiers for discriminating 1-mimute epochs of OSA segments from the normal segments, and to discriminate patients from the normal subjects.”
MethodPrediction of heart disease using multilayer perceptron neural network
Sonawane, J. S., & Patil, D. R. (2014) · International Conference on Information Communication and Embedded Systems (ICICES2014) · doi:10.1109/icices.2014.7033860 · Cited by 94
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Metadata
- Authors
- Al-Angari, H. M., & Sahakian, A. V.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 463-468
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2055163496
- Cited by
- 142
- References
- 2
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Recognition of Obstructive Sleep Apnea Syndrome Using Support Vector Machine Classifier. https://app.cochat.ai/papers/10.1109/titb.2012.2185809
- The paper
- Al-Angari, H. M., & Sahakian, A. V. (2012). Automated Recognition of Obstructive Sleep Apnea Syndrome Using Support Vector Machine Classifier. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2012.2185809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.