CoChat

Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea

Open access

The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Polysomnography (PSG) is treated as the gold standard for diagnosing obstructive sleep apnea (OSA). However, it is labor-intensive, time-consuming, and expensive. This study evaluates validity of overnight pulse oximetry as a diagnostic tool for moderate to severe OSA patients. METHODS: A total of 699 patients with possible OSA were recruited for overnight oximetry and PSG examination at the Sleep Center of a University Hospital from Jan. 2004 to Dec. 2005. By excluding 23 patients with poor oximetry recording, poor EEG signals, or respiratory artifacts resulting in a total recording time less than 3 hours; 12 patients with total sleeping time (TST) less than 1 hour, possibly because of insomnia; and 48 patients whose ages less than 20 or more than 85 years old, data of 616 patients were used for further study. By further considering 76 patients with TST < 4 h, a group of 540 patients with TST ≥ 4 h was used to study the effect of insufficient sleeping time. Alice 4 PSG recorder (Respironics Inc., USA) was used to monitor patients with suspected OSA and to record their PSG data. After statistical analysis and feature selection, models built based on support vector machine (SVM) were then used to diagnose moderate and moderate to severe OSA patients with a threshold of AHI = 30 and AHI = 15, respectively. RESULTS: The SVM models designed based on the oxyhemoglobin desaturation index (ODI) derived from oximetry measurements provided an accuracy of 90.42-90.55%, a sensitivity of 89.36-89.87%, a specificity of 91.08-93.05%, and an area under ROC curve (AUC) of 0.953-0.957 for the diagnosis of severe OSA patients; as well as achieved an accuracy of 87.33-87.77%, a sensitivity of 87.71-88.53%, a specificity of 86.38-86.56%, and an AUC of 0.921-0.924 for the diagnosis of moderate to severe OSA patients. The predictive outcome of ODI to diagnose severe OSA patients is better than to diagnose moderate to severe OSA patients. CONCLUSIONS: Overnight pulse oximetry provides satisfactory diagnostic performance in detecting severe OSA patients. Home-styled oximetry may be a tool for severe OSA diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12890-015-0017-z

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 ROC curves of ODI parameters for the diagnosis of severe and moderate/severe OSA patients with thresholds (a) AHI=30 and (b) AHI=15, respectively.
Figure 1 ROC curves of ODI parameters for the diagnosis of severe and moderate/severe OSA patients with thresholds (a) AHI=30 and (b) AHI=15, respectively.CC BY · PubMed Central
Figure 2 Bland-Altman plots of AHI vs ODI parameters after linear regression analysis in dataset 1: (a) yODI2=1.05×ODI2-5.39, R 2 =0.770; (b) yODI3=1.074×ODI3+5.987, R 2 =0.835; (c) yODI4T=1.099×ODI4T+11.599, R 2 =0.813; (d) yODI4A=1.014×ODI4A+9.091, R 2 =0.878; (e) yODI4A_2=0.881×ODI4A+0.161×ODI2+6.312, R 2 =0.881; and (f) yODI4A_3=0.86×ODI4A+0.173×ODI3+8.349, R 2 =0.882.
Figure 2 Bland-Altman plots of AHI vs ODI parameters after linear regression analysis in dataset 1: (a) yODI2=1.05×ODI2-5.39, R 2 =0.770; (b) yODI3=1.074×ODI3+5.987, R 2 =0.835; (c) yODI4T=1.099×ODI4T+11.599, R 2 =0.813; (d) yODI4A=1.014×ODI4A+9.091, R 2 =0.878; (e) yODI4A_2=0.881×ODI4A+0.161×ODI2+6.312, R 2 =0.881; and (f) yODI4A_3=0.86×ODI4A+0.173×ODI3+8.349, R 2 =0.882.CC BY · PubMed Central
Figure 3 Bland-Altman plots of AHI vs ODI parameters after linear regression analysis in dataset 1: (a) yODI4A_3_2=0.888×ODI4A-0.150×ODI3+0.168×ODI2+6.252, R 2 =0.881 and (b) yODI4A_4T_3_2=0.914×OD I4A-0.376×ODI4T+0.477×ODI3-0.004×ODI2+6.898, R 2 =0.882.
Figure 3 Bland-Altman plots of AHI vs ODI parameters after linear regression analysis in dataset 1: (a) yODI4A_3_2=0.888×ODI4A-0.150×ODI3+0.168×ODI2+6.252, R 2 =0.881 and (b) yODI4A_4T_3_2=0.914×OD I4A-0.376×ODI4T+0.477×ODI3-0.004×ODI2+6.898, R 2 =0.882.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Cited by

See all 115

Metadata

Authors
Hang, L.-W., Wang, H.-L., Chen, J.-H., Hsu, J.-C., Lin, H.-H., Chung, W.-S., & Chen, Y.-F.
Affiliations
  • China Medical University (TW)
  • National Taichung University of Science and Technology (TW)
  • Ministry of Health and Welfare (TW)
  • Central Taiwan University of Science and Technology (TW)
Corresponding author
  • Chung, Wei-Sheng
  • Chen, Yung-Fu
Venue
BMC Pulmonary Medicine
Published
2015-03-20
Volume
15
Issue
1
Pages
24-24
ISSN
1471-2466 (ISSN-L)
OpenAlex
W2103735154
Cited by
115
References
53
Citations by year
2026: 7 · 2025: 6 · 2024: 14 · 2023: 9 · 2022: 17 · 2021: 13 · 2020: 13 · 2019: 16 · 2018: 9 · 2017: 5 · 2016: 6
FWCI
4.91
Type
journal article
Language
en
Open access
Locations
  • BMC Pulmonary Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • National Science Council
  • Ministry of Science and Technology, Taiwan
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
obstructive sleep apnea, overnight pulse oximetry, polysomnography, OSA diagnosis, support vector machine, apnea-hypopnea index, diagnostic accuracy, total sleep time, feature selection, sleep monitoring devices, cost-effective diagnosis, sleep apnea severity classification
MeSH terms
Adult, Female, Humans, Male, Middle Aged, Oximetry, Oxyhemoglobins, Sensitivity and Specificity, Severity of Illness Index, Reproducibility of Results, Polysomnography, Sleep Apnea, Obstructive, Support Vector Machine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea. https://app.cochat.ai/papers/10.1186/s12890-015-0017-z
The paper
Hang, L.-W., Wang, H.-L., Chen, J.-H., Hsu, J.-C., Lin, H.-H., Chung, W.-S., & Chen, Y.-F. (2015). Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea. BMC Pulmonary Medicine. https://doi.org/10.1186/s12890-015-0017-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.