Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea
Open accessThe DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Polysomnography (PSG) is treated as the gold standard for diagnosing obstructive sleep apnea (OSA). However, it is labor-intensive, time-consuming, and expensive. This study evaluates validity of overnight pulse oximetry as a diagnostic tool for moderate to severe OSA patients. METHODS: A total of 699 patients with possible OSA were recruited for overnight oximetry and PSG examination at the Sleep Center of a University Hospital from Jan. 2004 to Dec. 2005. By excluding 23 patients with poor oximetry recording, poor EEG signals, or respiratory artifacts resulting in a total recording time less than 3 hours; 12 patients with total sleeping time (TST) less than 1 hour, possibly because of insomnia; and 48 patients whose ages less than 20 or more than 85 years old, data of 616 patients were used for further study. By further considering 76 patients with TST < 4 h, a group of 540 patients with TST ≥ 4 h was used to study the effect of insufficient sleeping time. Alice 4 PSG recorder (Respironics Inc., USA) was used to monitor patients with suspected OSA and to record their PSG data. After statistical analysis and feature selection, models built based on support vector machine (SVM) were then used to diagnose moderate and moderate to severe OSA patients with a threshold of AHI = 30 and AHI = 15, respectively. RESULTS: The SVM models designed based on the oxyhemoglobin desaturation index (ODI) derived from oximetry measurements provided an accuracy of 90.42-90.55%, a sensitivity of 89.36-89.87%, a specificity of 91.08-93.05%, and an area under ROC curve (AUC) of 0.953-0.957 for the diagnosis of severe OSA patients; as well as achieved an accuracy of 87.33-87.77%, a sensitivity of 87.71-88.53%, a specificity of 86.38-86.56%, and an AUC of 0.921-0.924 for the diagnosis of moderate to severe OSA patients. The predictive outcome of ODI to diagnose severe OSA patients is better than to diagnose moderate to severe OSA patients. CONCLUSIONS: Overnight pulse oximetry provides satisfactory diagnostic performance in detecting severe OSA patients. Home-styled oximetry may be a tool for severe OSA diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the general population, two Level 1b studies,499,616 three Level 2b studies,617–619 and one Level 3b620 found reasonably good correlations between oximetry ODI and PSG AHIs, though primarily when the 4% desaturation criteria was used to score respiratory events.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [618]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, a number of these studies were downgraded for using the oximetry off the PSG as the comparison to the PSG derived AHI,617,618 or for using highly selective populations.619”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [618]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183 · cited 1×
“Obstructive sleep apnea (OSA) is prevalent in 4% of men and 2% of women [4]; among them, up to 93% of women and 82% of men have not been diagnosed [5], resulting in an increased risk of 2–7 folds in causing motor vehicle crashes [6] and causing several chronic diseases, such as metabolic syndrome [7]; neurocognitive d…”
Background(2007) · Cited by 6,530
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
The Triad of Sleep Apnea, Hypertension, and Chronic Kidney Disease: A Spectrum of Common Pathology
Aziz, F., & Chaudhary, K. (2017) · Cardiorenal Medicine · doi:10.1159/000450796 · Cited by 3,267
Knowledge-based analysis of microarray gene expression data by using support vector machines
Brown, M. P. S., Grundy, W. N., Lin, D., Cristianini, N., Sugnet, C. W., Furey, T. S., Ares, M., & Haussler, D. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.1.262 · Cited by 2,308
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765 · cited 1×
“Obstructive sleep apnea (OSA) is prevalent in 4% of men and 2% of women [4]; among them, up to 93% of women and 82% of men have not been diagnosed [5], resulting in an increased risk of 2–7 folds in causing motor vehicle crashes [6] and causing several chronic diseases, such as metabolic syndrome [7]; neurocognitive d…”
BackgroundSleep Apnea and Cardiovascular Disease
Somers, V. K., White, D. P., Amin, R., Abraham, W. T., Costa, F., Culebras, A., Daniels, S., Floras, J. S., Hunt, C. E., Olson, L. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.002 · Cited by 1,487
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189375 · Cited by 1,450
Somers, V. K., White, D. P., Amin, R., Abraham, W. T., Costa, F., Culebras, A., Daniels, S., Floras, J. S., Hunt, C. E., Olson, L. J., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189420 · Cited by 1,297
Comparison of learning algorithms for handwritten digit recognition
LeCun, Y., Jackel, L. D., Bottou, L., Brunot, A., Cortes, C., Denker, J. S., Drucker, H., Guyon, I., Müller, U., Säckinger, E., et al. (1995) · Cited by 776
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Self-citationThe Value of Oxygen Desaturation Index for Diagnosing Obstructive Sleep Apnea: A Systematic Review
Rashid, N. H., Zaghi, S., Scapuccin, M., Camacho, M., Certal, V., & Capasso, R. (2021) · The Laryngoscope · doi:10.1002/lary.28663 · Cited by 115
“Hang et al., 201532 Cessation of airflow for ≥ 10 secs (i) Fall in SaO2 ≥ 4% from baseline (ii) Fall in SaO2 ≥ 3% from baseline Preceding period of normal breathing (i) mean of all-night saturation (ii) mean of the top 20% of oxyhemoglobin saturation values over the 1 min preceding the scanned oxyhemoglobin value AHI…”
MethodInfluentialDeep learning for obstructive sleep apnea diagnosis based on single channel oximetry
Levy, J., Álvarez, D., Campo, F. D., & Behar, J. A. (2023) · Nature Communications · doi:10.1038/s41467-023-40604-3 · Cited by 126
“However, most previous studies 4,5 focused on developing OSA screening tests with a binary classi fi cation task (OSA, non-OSA).”
Application of artificial intelligence in the diagnosis of sleep apnea
Bazoukis, G., Bollepalli, S. C., Chung, C. T., Li, X., Tse, G., Bartley, B. L., Batool‐Anwar, S., Quan, S. F., & Armoundas, A. A. (2023) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10532 · Cited by 116
Linz, D., Baumert, M., Catcheside, P., Floras, J., Sanders, P., Lévy, P., Cowie, M. R., & Doug McEvoy, R. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.04.076 · Cited by 77
Metadata
- Authors
- Hang, L.-W., Wang, H.-L., Chen, J.-H., Hsu, J.-C., Lin, H.-H., Chung, W.-S., & Chen, Y.-F.
- Affiliations
- China Medical University (TW)
- National Taichung University of Science and Technology (TW)
- Ministry of Health and Welfare (TW)
- Central Taiwan University of Science and Technology (TW)
- Corresponding author
- Chung, Wei-Sheng
- Chen, Yung-Fu
- Venue
- BMC Pulmonary Medicine
- Published
- 2015-03-20
- Volume
- 15
- Issue
- 1
- Pages
- 24-24
- ISSN
- 1471-2466 (ISSN-L)
- PMC
- PMC4407425
- OpenAlex
- W2103735154
- Semantic Scholar
- 39bc7c46e7e03aa852d85fa0c9d800a32d5b599b
- Cited by
- 115
- References
- 53
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 14 · 2023: 9 · 2022: 17 · 2021: 13 · 2020: 13 · 2019: 16 · 2018: 9 · 2017: 5 · 2016: 6
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- BMC Pulmonary Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Science Council
- Ministry of Science and Technology, Taiwan
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- obstructive sleep apnea, overnight pulse oximetry, polysomnography, OSA diagnosis, support vector machine, apnea-hypopnea index, diagnostic accuracy, total sleep time, feature selection, sleep monitoring devices, cost-effective diagnosis, sleep apnea severity classification
- MeSH terms
- Adult, Female, Humans, Male, Middle Aged, Oximetry, Oxyhemoglobins, Sensitivity and Specificity, Severity of Illness Index, Reproducibility of Results, Polysomnography, Sleep Apnea, Obstructive, Support Vector Machine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea. https://app.cochat.ai/papers/10.1186/s12890-015-0017-z
- The paper
- Hang, L.-W., Wang, H.-L., Chen, J.-H., Hsu, J.-C., Lin, H.-H., Chung, W.-S., & Chen, Y.-F. (2015). Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea. BMC Pulmonary Medicine. https://doi.org/10.1186/s12890-015-0017-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.