The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
On the magnetic field generated outside an inhomogeneous volume conductor by internal current sources
Abstract
The magnetocardiogram results from the detection of magnetic fields generated outside the body by electric current sources in the heart. Let the source current dipole moment per unit volume be Ji, the conductivityg, the electric potentialV, and the electric field intensityE. Then it may be shown that the magnetic fieldHis given by eitherH = (1/4\pi) \int J^{i} \times \nabla(1/r) dv + \sum_{i} \int (g' - g")(E \times dS_{i}/r), orH = (1/4\pi) \int J^{i} \times \nabla(1/r) dv + \sum_{i} \int (g' - g")V\nabla(1/r) \times dS_{i}, where the surface integral is over all surfaces Siseparating regions of different conductivity, i.e.,g' andg", andris the distance from the point of measurement to the element of volume or surface. The magnetic dipole momentmis given bym = \frac{1}{2} \int r_{1} \times J^{i}dv - \frac{1}{2} \sum_{i} \int (g'-g")Vr_{1} \times dS_{i}, where r1is a radius vector from an arbitrary origin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
On Bioelectric Potentials in an Inhomogeneous Volume Conductor
Geselowitz, D. B. (1967) · Biophysical Journal · doi:10.1016/s0006-3495(67)86571-8 · Cited by 332
Self-citationMagnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
Dorfmann, L., & Ogden, R. W. (2013) · Springer eBooks · doi:10.1007/978-1-4614-9596-3_2 · Cited by 113
Theory of Magnetic Detection of the Heart's Electrical Activity
Baule, G. M., & McFee, R. (1965) · Journal of Applied Physics · doi:10.1063/1.1714404 · Cited by 112
The magnetocardiogram—a new approach to the fields surrounding the heart
Stratbucker, R. A., Hyde, C. M., & Wixson, S. E. (1963) · IRE Transactions on Bio-Medical Electronics · doi:10.1109/tbmel.1963.4322823 · Cited by 18
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Metadata
- Authors
- Geselowitz, D.
- Venue
- IEEE Transactions on Magnetics
- Published
- 1970-06
- Volume
- 6
- Issue
- 2
- Pages
- 346-347
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2080137861
- Cited by
- 318
- References
- 6
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.