The DOI matches its Crossref record.
Measurements of particle size distribution parameters in ferrofluids
Abstract
A method is presented by means of which (for a ferrofluid with a lognormal distribution of particle size) it is possible to determine the standard deviation (σ) and median particle diameter (Dv) from the room temperature magnetisation curve. The method has been applied to several commercial ferrofluids, containing ferrite particles, and to fluids consisting of cobalt particles in toluene prepared by the method of Hess and Parker. The particle size distributions have also been measured by using an electron microscope. It has been found that the magnetic data gives estimates of the 'magnetic size distribution' parameters Dvmand σm, which differed from the 'physical size distribution' parameters Dvpand σpobtained from electron microscope data. It is found that Dvp> Dvm, and\sigma_{p} < \sigma_{m}. These observations are consistent with the results of Kaiser and Miskolczy and Granqvist and Buhrman.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Synthesis of phase-pure and monodisperse iron oxide nanoparticles by thermal decomposition
Hufschmid, R., Arami, H., Ferguson, R. M., Gonzales, M., Teeman, E., Brush, L. N., Browning, N. D., & Krishnan, K. M. (2015) · Nanoscale · doi:10.1039/c5nr01651g · Cited by 341
Nanoparticles for Imaging, Sensing, and Therapeutic Intervention
Bogart, L. K., Pourroy, G., Murphy, C. J., Puntes, V., Pellegrino, T., Rosenblum, D., Peer, D., & Lévy, R. (2014) · ACS Nano · doi:10.1021/nn500962q · Cited by 295
Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging
Khandhar, A. P., Ferguson, R. M., Arami, H., & Krishnan, K. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.087 · Cited by 152
Kratz, H., Taupitz, M., Ariza de Schellenberger, A., Kosch, O., Eberbeck, D., Wagner, S., Trahms, L., Hamm, B., & Schnorr, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190214 · Cited by 92
Metadata
- Authors
- Chantrell, R., Popplewell, J., & Charles, S.
- Venue
- IEEE Transactions on Magnetics
- Published
- 1978-09
- Volume
- 14
- Issue
- 5
- Pages
- 975-977
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2069499937
- Cited by
- 718
- References
- 0
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of particle size distribution parameters in ferrofluids. https://app.cochat.ai/papers/10.1109/tmag.1978.1059918
- The paper
- Chantrell, R., Popplewell, J., & Charles, S. (1978). Measurements of particle size distribution parameters in ferrofluids. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.1978.1059918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.