Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Design, construction, and performance of a large-volume magnetic shield

Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., Heino, J.·1982·IEEE Transactions on Magnetics

Abstract

A cubic magnetically shielded room has been constructed. The room consists of three concentric cubic shields, and the side length of the smallest shell is 2A5 m. It utilizes ferromagnetic and eddy current shielding, active noise compensation, and shaking to achieve a shielding factor of about 400 000 between 1 Hz and 100 Hz. At lower frequencies, the shielding drops gradually and is about 16 000 for a 0.1-Hz disturbance. The residual magnetic induction in the room is less than 5 nT, and the magnetic noise above 0.5 Hz is lower than that of the superconducting quantum interference device (SQUID) magnetometer used in the measurements. When the room was completed, its performance in shielding was better than that of any other room made before.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmag.1982.1061780

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 209

Metadata

Authors
Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., & Heino, J.
Venue
IEEE Transactions on Magnetics
Published
1982-01
Volume
18
Issue
1
Pages
260-270
ISSN
0018-9464 (ISSN-L)
OpenAlex
W1976783656
Cited by
209
References
1
FWCI
7.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design, construction, and performance of a large-volume magnetic shield. https://app.cochat.ai/papers/10.1109/tmag.1982.1061780
The paper
Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., & Heino, J. (1982). Design, construction, and performance of a large-volume magnetic shield. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.1982.1061780

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.