The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design, construction, and performance of a large-volume magnetic shield
Abstract
A cubic magnetically shielded room has been constructed. The room consists of three concentric cubic shields, and the side length of the smallest shell is 2A5 m. It utilizes ferromagnetic and eddy current shielding, active noise compensation, and shaking to achieve a shielding factor of about 400 000 between 1 Hz and 100 Hz. At lower frequencies, the shielding drops gradually and is about 16 000 for a 0.1-Hz disturbance. The residual magnetic induction in the room is less than 5 nT, and the magnetic noise above 0.5 Hz is lower than that of the superconducting quantum interference device (SQUID) magnetometer used in the measurements. When the room was completed, its performance in shielding was better than that of any other room made before.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Shielded Facility for Low-Level Magnetic Measurements
Cohen, D. (1967) · Journal of Applied Physics · doi:10.1063/1.1709590 · Cited by 38
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Self-citationElliott, S. J., & Nelson, P. A. (1993) · IEEE Signal Processing Magazine · doi:10.1109/79.248551 · Cited by 846
Signal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716
Hari, R., Hämäläinen, M., Ilmoniemi, R., Kaukoranta, E., Reinikainen, K., Salminen, J., Alho, K., Näätänen, R., & Sams, M. (1984) · Neuroscience Letters · doi:10.1016/0304-3940(84)90474-9 · Cited by 451
Self-citationMEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Metadata
- Authors
- Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., & Heino, J.
- Venue
- IEEE Transactions on Magnetics
- Published
- 1982-01
- Volume
- 18
- Issue
- 1
- Pages
- 260-270
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W1976783656
- Cited by
- 209
- References
- 1
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design, construction, and performance of a large-volume magnetic shield. https://app.cochat.ai/papers/10.1109/tmag.1982.1061780
- The paper
- Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., & Heino, J. (1982). Design, construction, and performance of a large-volume magnetic shield. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.1982.1061780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.