The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Shielded Facility for Low-Level Magnetic Measurements
Abstract
A facility has been constructed for the detection and measurement of time-varying magnetic fields of ∼10−9 G amplitude, in a bandwidth of 0.5 to 100 000 cps. The facility includes a shielded room and magnetic detector, which now consists of a copper coil, eventually to be cooled in liquid helium, feeding a parametric amplifier; it will initially be used to investigate bioelectric current flow in human heart muscles by mapping the time-varying fields outside the body. The shielded room now has two layers of 0.060 in. Moly-Permalloy, and a third inner layer of 0.19 in. aluminum enclosing a 86 in.×88 in.×88 in. volume will soon be installed. Measured shielding factors are given; at present magnetic ``shaking'' is used to produce a shielding factor of ∼400 in the 0–5 cps range, which rises rapidly with increasing frequency.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a major milestone in MCG was the invention of the first superconducting quantum interference device (SQUID) (10) and the installation of SQUID within the magnetically shielded room (MSR) of the Massachusetts Institute of Technology (MIT) that radically reduce external electromagnetic interference by at least a factor of about 1,000 (11, 12)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [11]
Citations
Cites
Design of a room-size magnetic shield
Patton, B. J., & Fitch, J. L. (1962) · Journal of Geophysical Research Atmospheres · doi:10.1029/jz067i003p01117 · Cited by 44
ENHANCEMENT OF FERROMAGNETIC SHIELDING AGAINST LOW-FREQUENCY MAGNETIC FIELDS
Cohen, D. (1967) · Applied Physics Letters · doi:10.1063/1.1754854 · Cited by 38
Self-citationEffect of a Superposed Alternating Field on Apparent Magnetic Permeability and Hysteresis Loss
Spooner, T. (1925) · Physical Review · doi:10.1103/physrev.25.527 · Cited by 20
XXXVI. Observations on the different theories of philosophers to explain the phænomena of combustion
Portal, C. (1803) · The Philosophical Magazine · doi:10.1080/14786440308676258 · Cited by 1
Research works printed but not linked: 3
- 1933, Phil. Mag., 15, 202
- 1915, Verhandl. Deut. Physik. Ges., 17, 369
- 1957, Z. Angew. Phys., 9, 111
Cited by
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Design, construction, and performance of a large-volume magnetic shield
Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., & Heino, J. (1982) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1982.1061780 · Cited by 209
Large-volume conventional magnetic shields
Cohen, D. (1970) · Revue de Physique Appliquée · doi:10.1051/rphysap:019700050105300 · Cited by 78
Self-citationClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
“Providing a significant improvement in sensitivity and spatial resolution of MF measurements, a major milestone in MCG was the invention of the first superconducting quantum interference device (SQUID) (10) and the installation of SQUID within the magnetically shielded room (MSR) of the Massachusetts Institute of Tech…”
Background
Metadata
- Authors
- Cohen, D.
- Affiliations
- University of Illinois Chicago (US)
- Corresponding author
- Cohen, David
- ORCID
- Cohen, David
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1967-03-01
- Volume
- 38
- Issue
- 3
- Pages
- 1295-1296
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2071716225
- Cited by
- 38
- References
- 4
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 2 · 2019: 1 · 2018: 2 · 2016: 1 · 2013: 1
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physics (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Measurements
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- magnetic shielding, time-dependent magnetic field, parametric amplifiers, liquid helium cooling, shielding factor, myocardium
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Shielded Facility for Low-Level Magnetic Measurements. https://app.cochat.ai/papers/10.1063/1.1709590
- The paper
- Cohen, D. (1967). A Shielded Facility for Low-Level Magnetic Measurements. Journal of Applied Physics. https://doi.org/10.1063/1.1709590
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.