CoChat

Measurement of MCG in Unshielded Environment Using a Second-Order SQUID Gradiometer

Kang, C.S., Lee, Y.H., Yu, K.K., Kwon, H., Kim, J.M., Kim, K., Lim, H.K., Park, Y.K., Lee, S.G. · 2009 · IEEE Transactions on Magnetics

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

In this paper, we fabricated a low-TCsecond-order superconducting quantum interference device gradiometer (SQUID) to measure magnetocardiography (MCG) in unshielded environment. The second-order gradiometer consists of the pickup coil and the SQUID. The pickup coil is formed with two single-turn coils and one double-turn coil. The three coils are connected in order of single-, double-, and single-turn coil. The coupling polarity of two single coils is opposite to the double-turn coil. The SQUID is based on double relaxation oscillation SQUID (DROS), which consists of a hysteretic signal SQUID, a reference junction, and shunted a relaxation circuit with a resistor and an inductor. The DROS has ten times larger flux-to-voltage transfer coefficient (~ 1 mV/Phi0) than that of the conventional SQUID. Therefore, DROS could be operated with a simple flux-locked loop circuit. The pickup coil and the SQUID were fabricated on the independent wafers and connected superconductively using an Nb wire. The overall size of the second-order gradiometer is 94 times 12 mm2with a baseline of 35 mm. The average field noise was about 8 fT /radicHz at 100 Hz with the second-order gradiometer in shielded or unshielded environment. The noise level is low enough to measure MCG signals in the unshielded environment. Finally, we measure the MCG in shielded and unshielded environments by using the second-order gradiometer and compared the signal characteristics measured in both environments.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmag.2009.2018871

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 8 references

Research works printed but not linked: 1

  1. jaszezuk, 1991, Meas Sci Technol, 2

Cited by

See all 19

Metadata

Authors
Kang, C. S., Lee, Y. H., Yu, K. K., Kwon, H., Kim, J. M., Kim, K., Lim, H. K., Park, Y. K., & Lee, S. G.
Affiliations
  • Korea University (KR)
  • Korea Research Institute of Standards and Science (KR)
Venue
IEEE Transactions on Magnetics
Published
2009-06
Volume
45
Issue
6
Pages
2882-2885
ISSN
0018-9464 (ISSN-L)
OpenAlex
W2163265273
Cited by
18
References
8
Citations by year
2025: 2 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2012: 1
FWCI
0.26
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Magnetics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
Keywords
magnetocardiography, unshielded environment, pickup coil, field noise, flux-locked loop

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of MCG in Unshielded Environment Using a Second-Order SQUID Gradiometer. https://app.cochat.ai/papers/10.1109/tmag.2009.2018871
The paper
Kang, C. S., Lee, Y. H., Yu, K. K., Kwon, H., Kim, J. M., Kim, K., Lim, H. K., Park, Y. K., & Lee, S. G. (2009). Measurement of MCG in Unshielded Environment Using a Second-Order SQUID Gradiometer. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2009.2018871

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.