CoChat

Comprehensive Analysis of Magnet Defect Fault Monitoring Through Leakage Flux

Goktas, Taner, Zafarani, Mohsen, Lee, Kun Wang, Akin, Bilal, Sculley, Terry · 2017 · IEEE Transactions on Magnetics
Cited by 119

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This paper presents a detailed magnet defect fault detection analysis through fluxgate sensors by monitoring the leakage flux around permanent magnet synchronous motors. The flux spectra of electric machines contain direct and most critical information to monitor and characterize magnet defect faults and their progressions. In the mainstream diagnosis techniques based on phase current and back-EMF analysis, the fault corresponding signature characteristics may vary and cause misleading results depending on motor topology, winding configuration, number and location of defective magnets, and controller parameters. In this paper, it is shown that leakage flux analysis provides some superior results for magnet defect diagnosis. For this purpose, the fault patterns in the leakage flux spectrum are exhaustively analyzed at different torque/speed profiles. Simulation and experimental results show that the deployment of a direction sensitive fluxgate sensor in magnet defect fault detection yields very promising results both in time and frequency domain analyses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmag.2016.2617318

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 16

  1. 10.1109/TIE.2014.2361115 · DOI · Paper page
  2. 10.1109/DEMPED.2009.5292770 · DOI · Paper page
  3. 10.1109/TIE.2010.2066538 · DOI · Paper page
  4. 10.1049/iet-epa.2013.0176 · DOI
  5. zafarani, 2016, A comprehensive magnet defect fault analysis of permanent-magnet synchronous motors, IEEE Trans Ind Appl, 52, 1331, 10.1109/TIA.2016.2561900 · DOI
  6. 2016, DRV425 Fluxgate Magnetic-Field Sensor Datasheet
  7. rosero, 2007, Fault detection by means of wavelet transform in a PMSM under demagnetization, Proc Annu Conf IEEE Ind Electron Soc (IECON), 1149
  8. 10.1109/IAS.2003.1257729 · doi:10.1109/ias.2003.1257729
  9. 10.1109/ELECTROMOTION.2009.5259143 · doi:10.1109/electromotion.2009.5259143
  10. 10.1109/ICElMach.2012.6350083 · doi:10.1109/icelmach.2012.6350083
  11. 10.1109/IECON.2009.5414841 · doi:10.1109/iecon.2009.5414841
  12. 10.1109/ICElMach.2012.6350099 · doi:10.1109/icelmach.2012.6350099
  13. 10.1109/GREEN.2011.5754883 · doi:10.1109/green.2011.5754883
  14. 10.1109/IEMDC.2005.195805 · doi:10.1109/iemdc.2005.195805
  15. 10.1109/TIA.2003.816531 · DOI · Paper page
  16. 10.1109/MELCON.2008.4618482 · doi:10.1109/melcon.2008.4618482

Cited by

See all 119

Metadata

Authors
Goktas, T., Zafarani, M., Lee, K. W., Akin, B., & Sculley, T.
Venue
IEEE Transactions on Magnetics
Published
2017-04
Volume
53
Issue
4
Pages
1-10
ISSN
  • 0018-9464 (ISSN-L)
  • 1941-0069
OpenAlex
W2530835130
Cited by
119
References
2
FWCI
4.49
Type
journal article
Language
en
Open access
closed
Funders
  • SRC TxACE Center (1836.149)
  • Texas Instruments Inc

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.