The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A Back-emf Based Method to Detect Magnet Failures in PMSMs
Abstract
Demagnetization faults are troublesome because they have a profound impact on the overall performance of permanent magnet synchronous motors (PMSMs). This work presents and verifies experimentally a system to detect such faults which is based on the measure of the zero sequence voltage component (ZSVC). The proposed method is also appropriate for inverter fed machines and is particularly useful when dealing with fault tolerant systems. A fault severity index which allows quantifying the harshness of such faults is also proposed and its behavior is analyzed from experimental data. Features of the proposed method include low computational burden, simplicity and high sensitivity. Experimental results conducted at different speed and load conditions show the potential of the proposed fault severity index for online diagnosis of demagnetization failures.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The use of BEMF analysis is characterized by the lack of robustness to temperature changes of PMs, but the method is simple to implement.
“The use of BEMF analysis is characterized by the lack of robustness to temperature changes of PMs [3], but the method is simple to implement [29], [95].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [95]
Citations
Cites
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J.-C., Riba, J., & Espinosa, A. G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 285
Self-citationDetecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Ruoho, S., Kolehmainen, J., Ikäheimo, J., & Arkkio, A. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033592 · Cited by 265
Ruiz, J.-R. R., García, J. R., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231
Self-citationControl Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
Kim, K.-C., Lim, S., Koo, D. H., & Lee, J. (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.879077 · Cited by 193
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Yu, S., & Ren (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.871637 · Cited by 128
Briz, F., Degner, M. W., García, P., & Díez, A. B. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.926773 · Cited by 94
Magnetic Characteristics Investigation of an Axial-Axial Flux Compound-Structure PMSM Used for HEVs
Zheng, P., Zhao, J., Liu, R., Tong, C., & Wu, Q. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2042042 · Cited by 79
Magnets faults characterization for Permanent Magnet Synchronous Motors
Casadei, D., Filippetti, F., Rossi, C., & Stefani, A. (2009) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2009.5292770 · Cited by 75
Anisotropic fracture behavior of sintered rare-earth permanent magnets
Li, W., Li, A., & Wang, H. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.852948 · Cited by 63
Riba, J., Espinosa, A. G., Romeral, L., & Cusidó, J. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.04.010 · Cited by 51
Self-citationUrresty, J.-C., Riba, J., Romeral, L., et al. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2062529 · Cited by 51
Self-citationDetecting rotor faults in permanent magnet synchronous machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2003) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2003.1234573 · Cited by 48
Flagged first, then by citations
Cited by
Sorted by citations
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The use of BEMF analysis is characterized by the lack of robustness to temperature changes of PMs [3], but the method is simple to implement [29], [95].”
MethodFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
Self-citationDemagnetisation fault detection in PMSM using zero sequence current components
Ding, S., Hang, J., Li, H., & Wang, Q. (2017) · Electronics Letters · doi:10.1049/el.2016.2600 · Cited by 6
Metadata
- Authors
- Urresty, J.-C., Riba, J.-R., & Romeral, L.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Riba, Jordi-Roger
- Venue
- IEEE Transactions on Magnetics
- Published
- 2013-01
- Volume
- 49
- Issue
- 1
- Pages
- 591-598
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2093444382
- Cited by
- 151
- References
- 16
- Citations by year
- 2026: 2 · 2025: 13 · 2024: 11 · 2023: 13 · 2022: 11 · 2021: 10 · 2020: 14 · 2019: 15 · 2018: 12 · 2017: 12 · 2016: 10 · 2015: 14 · 2014: 7 · 2013: 6
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, demagnetization fault, back electromotive force, fault detection, online diagnosis, inverter-fed machines, fault-tolerant systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›