CoChat

Analysis of Magnetic-Flux Leakage (MFL) Data for Pipeline Corrosion Assessment

Peng, Xiang, Anyaoha, Uchenna, Liu, Zheng, Tsukada, Kazuhiko · 2020 · IEEE Transactions on Magnetics
Cited by 159

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Oil and gas pipelines transport and distribute large quantities of oil products and natural gas to industrial and residential customers over a long distance. However, pipeline failures could lead to enormous hazards and safety issues. Metal loss, due to corrosion, is a significant cause for pipeline failures. To detect and quantify metal loss, in-line inspection (ILI) is carried out periodically to assess the integrity of the pipeline. Among all the ILI techniques, magnetic-flux leakage (MFL) is the most popular one due to its high efficiency, robustness, and good applicability to both oil and gas pipelines. This article provides a comprehensive review of the pipeline corrosion assessment with the MFL technique from the data analytic perspective. The analyses of the MFL signal and data contribute to both corrosion quantification and prediction. In this article, the state of the art for the MFL measurement technique is briefly reviewed first. For corrosion quantification, the signal processing methods together with the characterization models, which aim to enhance the measurement and characterize the corrosion, are described and discussed. For corrosion prediction, this article investigates multiple MFL data matching methods, which align defects from successive ILI runs. Subsequently, corrosion growth models, which aim to predict the future corrosion status, are presented. Besides, the reliability analysis of the corroded pipeline is reviewed. The potential of fusing MFL with other non-destructive testing (NDT) techniques are explored as well. At the end of this article, we summarize the existing issues and describe the trends for future research on pipeline corrosion assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmag.2020.2981450

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 159

Metadata

Authors
Peng, X., Anyaoha, U., Liu, Z., & Tsukada, K.
Venue
IEEE Transactions on Magnetics
Published
2020-06
Volume
56
Issue
6
Pages
1-15
ISSN
  • 0018-9464 (ISSN-L)
  • 1941-0069
OpenAlex
W3011350210
Cited by
159
References
39
FWCI
8.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of Magnetic-Flux Leakage (MFL) Data for Pipeline Corrosion Assessment. https://app.cochat.ai/papers/10.1109/tmag.2020.2981450
The paper
Peng, X., Anyaoha, U., Liu, Z., & Tsukada, K. (2020). Analysis of Magnetic-Flux Leakage (MFL) Data for Pipeline Corrosion Assessment. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2020.2981450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.